0 TENNESSEE VALLEY AUTHORITY cH4 t14NCOGA. TENNESSEC 374ot 1750 Chestnut Street Tower II

/,b l/g May 22, 1981 g\\

@ [0re Mr. James P. O'Reilly, Director 6

N U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement 9 5-Region II 8

101 Marietta Street, suite 3100 Y' %.

Atlanta, Georgia 30303 N N ' l ' C'

Dear Mr. O'Reilly:

TENNESSEE VALLEY AUTHORITY - SEQUOYAH NUCLEAR PLANT UNIT 1 - DOCKET No. 50-327 - FACILITY OPERATING LICENSE DPR REPORTABLE OCCURRENCE REPORT SQRO-50-327/81049 The enclosed report provides details concerning the failure of a containment isolation valve to close when a radiation monitor spike initiated a spurious containment isolation. The valve's inoperability placed the plant in action statement "b" of limiting condition for operation 3.6.3.1 and is reported in accordance with Sequoyah unit 1 Tachnical Specifi-cation 6.9.1.13.b.

Very truly yours, TENNESSEE VALLEY AUTHORITY H. J. Green Director of Nuclear Power Enclosure (3) cc (Enclosure):

Director (3)

Office of Management Information and Program Control U.S. Nuclear Regulatory Commission Washington, DC 20555 j

Director ('.0)

Office of Inspeccion and Enforcement 7

U.S. Nuclear Regulatory Commission Washington DC 20559 l

Mr. Bill Lavallee Nuclear Safety Analysis Center Palc Alto, California 94303 l

NRC Inspector, Sequoyah l

8105270 @