ML20003H233

From kanterella
Jump to navigation Jump to search
Data Re Offsite Readings Conducted for Purpose of Detecting &/Or Measuring Levels of Background Radiation at or Near Facility from Jan 1977 - Dec 1979
ML20003H233
Person / Time
Site: San Onofre  
Issue date: 12/31/1979
From:
NRC
To:
Shared Package
ML20003H226 List:
References
FOIA-81-86 NUDOCS 8105050379
Download: ML20003H233 (6)


Text

_ _ _ _ _, _ _ _

if s_

r 8 "E" ATTACitMENT 3 San Dieno Co.. CA 1977 Madium or Split or Location Distance &

California Licensee thway Sampled Duplicate Sample Name Direction Date Pesults (HSL Results)

Results ternal Duplicate FIRST Units in: mR rect TLD QUARTER diation Monitoring Systems

  1. 1 San Clemente 5 Km N.W.

17.0 2 3.4 (21.6 2.9) 29.6 ! 2.0

  1. 3 Camp San Onofre 8 Km E.

21.5 4.3 (22.5 3.1) 30.8 ! 2.6

  1. 6 Old Rt. 101 5 Km S.E.

15.1 t 3.0 (18.2 2.5)

NR

  1. 7 30.3 2.0 Old Rt. 101 18 Km E.

19.5 i 3.9

  1. 10 Bluff

.8 KM N.W.

20.7 4.1 (24.3 ! 3.5) 31.0 1 2.0 Control 25.0 t 5.0 (22.6 1 2.9) 33.4 1 1.4 SECOND QUARTER

  1. 1 14.8 3,0 (28.0 2.2) 28.4 5.5
  1. 3 15.4 2 3.1 (32.4 1 2.3) 33.4 2 2.2
  1. 6 (27.412.2) 24.3 1 2.8
  1. 7 11.6 2.3
  1. 10 19.6 1 3.9 (34.2 1 2.3) 29.2 1 2.8 Control 20.4 t 4.1 (29.0 1 2.1) 28.2 1 2.9 Cr*

f*

i on k3 anta Ana (50 Km N.N.W.) for California results, San Clemente (5 Km N.W.) for HSL results, and Sunnyvale (600 Km N.W.)

jj sr licznsee results.

c3 k

05

ATTACIDENT 3 Songs San Diego Co., CA 1977 Medius or Split or Location Distance &

California Licensee athway Sampled Duplicate Sample Name Direction Date Results (HSL Results)

Results xternal Duplicate THIRD Units in: mR irect TLD QUARTER adiation Monitoring Systems

  1. 1 1h.2 1 2.8 (21.4 ! 3 7) 2h.2 0.6
  1. 3 16.4 3.3 (21.9 3.9) 28.1 2 0.9
  1. 6 12.2 2.h (17 7 3.h) 21.8 1.3
  1. 7 12.8 1 25
  1. 10 16.9 3.h (21.0 h.8) 28.8 1.3 Control 17.5 3.5

(.22.2 3.6) 21.1 0.5 FOURTH QUARTER

  1. 1 15.9 3.1 (24.0 z h.1) 29 1 2.8
  1. 3 17 3 35 (25.7 h.7) 33.5 2.3
  1. 6 12 7-A 25 (20.2 h.4) 22.h' 1.7
  1. 7 13.2 2.6
  1. 10 17.8 3.6 (25.p h.3) 29 2 1 1.7 Control 18.3 1 3.7 (28.2 6.0) h2.6 3.2 ANNUAL TOTAL e

w

  1. 1 61 9 ~ 12.h (95 0 1 12 9) 111.2 10 9
  1. 3 70.6 14.1 (103 14

)

126 A 8

  1. 6 53.3 10 7 (83.5 1 12 5) 91 5 8.3-
  1. 7 57 1 11.h-
  1. 10 75 0 15 0 (105 15

)

118

!' 8 CONTROL 81.2 16.2 (102 15

)

125 8

O

.u usu su ATTAClIMENT 3 SinR4 S*n Dirgn Cn., CA 1978

, ~.

H:diua or Split or Location Distance &~'

ithway S:mpled Duplicate Sample Name Direction Date California Results (llSL Results) Licensee Results ttern21 Duplicate FIRST Units in: mR treet TLD QUARTER idtaticn Monitoring Systems

  1. 1 San Clemente 5 Km N.W.

15 15.8 4.6 30.9 1.2

  1. 3 Camp San Onofre 8.lOn E.

17.5 15.4 4.1 35.0 t

.8

  1. 6 Old Rt. 101 5 Km S.E.

13 10.3 1 3.7 27.7 1 1.2

  1. 7 Old Rt. 101 18 Km E.

12 29.4 1 2.0

  1. 10 Bluff

.8 Km N.W.

19 16.1 1 3.7 30.4 !

.8 Control 20 17.4 1 4.0 31.8

.8 SECOND QUARTER

  1. 1 15 19.4 3.3 '

34.3 " 1. 2

  1. 3 17.5 19.6 1 3.4 41.1 4.8
  1. 6 13 15.9 4.4 33.5 i

.7

  1. 7 14 39.8 i 4.7
  1. 10 17.5 22.5 1 3.1 38.4 1 3.6 Control 19 21.4 1 4.1 40.9 1 4.1 Santa Ana (50 Km N.N.W.) for California results, San elemente (5 Km N.W.) for llSL rescits, and Sunnyvale (600 Km N.W.) for lic:n=ec results.

San Diego Co., MA\\

$#Ma ATTACKHENT 3 Songs s.

e H:dium or Split or Location Distance ithway Sampled Duplicate Sample Name Direction Date California Results (HSL Results) Licensee Results THIRD Units in: mR ~

sternal Duplicate treet TLD QUARTER ndiaticn Monitoring Systems 15 20.3 1 2.6 32.4 ! 2.9

  1. 1 17.5 22.2 2.8
  1. 3 12 14.9 1 2.4 30.9 t 4.1
  1. 6 36.0 1 4.1 13
  1. 7
  1. 10 17.5 23.9 1 3.4 35.4 1 3.5 17.5 22.6 ! 3.3 Control FOURTH QUARTER 16 30.1 1 2.4 29.3 1 2.1
  1. 1 17.5 28.7 2.2 30.5 2.9
  1. 3 14 24.6 1 2.9 27.2 1

.9

  1. 6 29.5 1 2.1
  1. 7 17.5
  1. 10 19 32.1 3.5 28.6 3.1 Control 19 39.7 ! 2.2 '

37.4.1 2.2 ANNUAL TOTAL 61 86 127

  1. 1 70 86 142
  1. 3 52 66 119
  1. 6 135
  1. 7 56.5 73 95 133
  1. 10 75.5 96 147 Control A

san Diego @s>., @s aNRNi ATTACIDiEHT 3

Song,

~,

n Medium or Split or Location D1's'ta'nce &

California (HSL Licensee nth ey Sampled Duplicate Sample Name Direction Date.

Results Results)

Results FIRST Units in:

cternti Duplicate treet TLD QUARTER (mR per quarter) adiction Monitoring Systems

  1. 1 San Clemente 5 Km N.W.

19.6 20.4 38.2

  1. 3 Camp San Onofre 8 Km E.

20.4 22.6 38.0

  1. 6 Old Rt. 101 5 Km S.E.

14.0 22.8 32.8 B7 38.5 Old Rt. 101 0.8 Km E.

20.4

  1. 10 Bluff

.8 Km N.W.

19.4 18.5 36.1 Control' 18.8 24.4 44.1 SEC0tm QUARTER 15.3

'18.1 26.9

  1. 1
  1. 3 18.3 22.1 29.3 11.8 18.6 23.6
  1. 6 28.6 17.1
  1. 7 16.3 21.0 27.8
  1. 10 Control 24.7 28.7 33.9 Sinta Ana (50 Km N.N.W.) for California Results, San Clemente (5 Km N.W.) for HSL.Results, and Huntington Beach o

for Licensee Results.

4

e AITAClQiENT 3 Songe San Disg9 Ca., CA 1979

+

Medium or Split or Location Di'st$nce &

California (llSL Licensee thvay Sampled Duplicate Sample Name Direction Date Results Results)

Results i

tornal,

Duplicate TilIRD Units in Arect TLD QUARTER mR I:diaticn Monitoring Systems

  1. 1 17.2 19.6 31.7
  1. 3 18.2 21.8 36.4
  1. 6 11.8 16.6 29.6 34.4
  1. 7 15.5 17.9 20.9 35.1
  1. 10 Control 30.1 28.8 37.3 l

FOURTil QUARTER 1

  1. 1 14.2 24.8 27.2
  1. 3 15.0 27.5 30.0 I
  1. 6 11.1 18.9 24.7' 29.2 l
  1. 7 16.8
  1. 10 17.7

,25.2 30.4 control 24.8 35.3 36.5 ANNUAL TOTAL

  1. 1 67 83 124
  1. 3 72 94 134
  1. 6 49 77 111
  1. 7 70 131
  1. 10 71 86.

,129 Control 98 117 152

(

g 9

9

. A g:2 20 t

s 8 "E8 ATTACHMENT 3 San Dieno Co.. CA 1977 s

Medium or Split or Location Distance &

California Licensee Pathway Sampled Duplicate Sample Name Direction Date Results (HSL Results)

Results External Duplicate FIRST Units in: mR Direct TLD QUARTER Radiation Monitoring Systems

  1. 1 San Clemente 5 Km N.W.

17.0 ! 3.4 (21.6 2.9) 29.6 1 2.0

  1. 3 Camp San Onofre 8 Km E.

21.5 4.3 (22.5 3.1) 30.8 2.6

  1. 6 Old Rt. 101 5 Km S.E.

15.1 3.0 (18.2 2.5)

NR

  1. 7 Old Rt. 101 18 Km E.

19.5 i 3.9 30.3 1 2.0

  1. 10 Bluff

.8 KM N.W.

20.7 4.1 (24.3 3.5) 31.0 ! 2.0 Control 25.0 5.0 (22.6 ! 2.9) 33.4 1.4 SECOND QUARTER

  1. 1 14.8 1 3.0 (28.0 1 2.2) 28.4 5.5
  1. 3 15.4 ! 3.1 (32.412.3) 33.4 1 2.2
  1. 6 (27.4 2.2) 24.3 2 2.8
  1. 7 11.6 2.3
  1. 10 19.6 ! 3.9 (34.2 2.3) 29.2 1 2.8 Control 20.4 !

4.1 (29.0 1 2.1) 28.2 1 2.9 f

DSanta Ana (50 Km N.N.W.) for California results, San Clemente (5 Km N.W.) for HSL results, and Sunnyvale (600 Km N.W.)

for licensee results.

(

s ATTACEMENT 3 Songs San Diego Co.. CA 1977

~

Medium or Split or Location Distance &

California Licensee Pathway Samnled Duplicate Sample Name Direction Date Results (HSL Results)

Results External Duplicate THIRD Units in: mR Direct TLD QUARTER Radiation Monitoring Systems

  1. 1 14.2 1 2.8 (21.4 i 3.7) 24.2 0.6
  1. 3 16.4 1 3.3 (21.9 3.9) 28.1 0.9
  1. 6 12.2 1 2.h (17 7 3.h) 21.8 1.3
  1. 7 12.8 1 2.5
  1. 10 16.9 3.4 (21.0 h.8) 28.8 1.3 Control 17 5 1 3.5 (22.2 3.6) 21.1 0.5 FOURTH QUARTER
  1. 1 15 9 3.1 (24.0 h.1) 29.1 2.8
  1. 3 17 3 i 35 (25 7 h.7) 33.5 2 2.3
  1. 6 12.7 2 25 (20.2 h.4) 22.4' 1.7
  1. 7 13.2 2.6
  1. 10 17.8 3.6 (25.p h.3) 29 2 2 1.7 Control 18.3 1 3.7 (28.2 6.0) 42.6 3.2 ANNUAL TOTAL
  1. 1 61.9 12.4 (95 0 1 12 9) 111.2 10 9
  1. 3 70.6 14.1 (103 i lh

)

126 8

  1. 6 53.3 10.T (83 5 12 5) 91.5 8.3-
  1. 7 57.1 2 11.h
  1. 10 75 0 15 0 (105 15

)

118 8

CONTROL 81.2 1 16.2 (102 1 15 )

125 i 8

AG5c su ATTACHMENT 3 Songo Sen Diego Co., CA 1978 e

M:dium or Split or Location Distance &~'

Pcthway Sampled Dupliccte Sample Name Direction Date Californ10 Results (llSL Results) Licensee Results l

l F.xternal Duplicate FIRST Units in: mR Direct TLD QUARTER Radiation Monitoring Systems

  1. 1 San Clemente 5 Km N.W.

15 15.8 4.6 30.9 1.2

  1. 3 Camp San Onofre 8.Km E.

17.5 15.4 4.1 35.0 t

.8

  1. 6 Old Rt. 101 5 Km S.E.

13 10.3 3.7 27.7 1.2

  1. 7 Old Rt. 101 18 Km E.

12 29.4 1 2.0

  1. 10 Bluff

.8 Km N.W.

19 16.1 3.7 30.4

.8 Control 20 17.4 4.0 31.8 i

.8 SECOND QUARTER

  1. 1 15 19.4 3.3 '

34.3 1.2

  1. 3 17.5 19.6 1 3.4 41.1 1 4.8
  1. 6 13 15.9 i 4.4 33.5 i

.7

  1. 7 14 39.8 ! 4.7
  1. 10 17.5 22.5 i 3.1 38.4 3.6 Control 19 21.4 1 4.1 40.9 ! 4.1
  • Santa Ana (50 Km N.N.W.) for California results, San clemente (5 Km N.W.) for IISL results, and Sunnyvale (600 Km N.W.) for licensee results.

ATTACl[HENT 3 Songs Scn Dien C,.,

CA

)M78

~.

Midium or Split or Location Distance &'

Pathway Sampled Duplicate Sample Name Direction Date California Results (llSL Results) Licensee Results Tl!IRD Units in: mR '

2xternci Duplicate QUARTER Direct TLD R diatien Monitoring Systems 15 20.3 2.6 32.4 ! 2.9

  1. 1 17.5 22.2 2.8
  1. 3 12 14.9 2.4 30.9 i 4.1
  1. 6 36.0 1 4.1 13
  1. 7 17.5 23.9 t 3.4 35.4 1 3.5
  1. 10 17.5 22.6 1 3.3 Control FOURTil QUARTER 16 30.1 1 2.4 29.3 1 2.1
  1. 1 17.5 28.7 t 2.2 30.5 ! 2.9
  1. 3 14 24.6 1 2.9 27.2 i

.9

  1. 6 29.5 2.1 17.5
  1. 7 19 32.1 1 3.5 28.6 1 3.1
  1. 10 19 39.7 1 2.2' 37.4.1 2.2 Control ANNUAL TOTAL 61 86 127
  1. 1 70 86 142
  1. 3 52 66 119
  1. 6 135 56.5
  1. 7 73 95 133
  1. 10 75.5 96 147 control

Medium or Split or Location Dista'nce &

California (HSL Licensee

~

Pcthway Sampled Duplicate Staple Name Direction Date.

Results Results)

Results FIRST Units in:

Externst Duplicate QUARTER (mR per quarter)

Direct TLD Radiation Monitoring Systems

  1. 1 San Clemente 5 Km H.W.

19.6 20.4 38.2

  1. 3 Camp San Onofre 8 Km E.

20.4 22.6 38.0

  1. 6 Old Rt. 101 5 Km S.E.

14.0 22.3 32.8

  1. 7 38.5 Old Rt. 101 0.8 Km E.

20.4

  1. 10 Bluff

.8 Km N.W.

19.4 18.5 36.1 control-18.8 24.4 44.1 SECOND QUARTER

  1. 1 15.3

'18.1 26.9 18.3 22.1 29.3

  1. 3 11.8 18.6 23.6
  1. 6 28.6 17.1
  1. 7 16.3 21.0 27.8
  1. 10 24.7 28.7 33.9 Control e

Sinta Ana (50 Km N.N.W.) for California Results, San Clemente (5 Km N.W.) for HSL.Results, and Huntington Beach for Licensee Results.

A

Page 13 ATTACHMENT 3 Snngs S n Dicgn C3.,

CA 1979 Medium or Split or Location Distance &

California (HSL Licensee Pcthway Sae;1ed Duplicate Sample Name Direction Date Results Results)

Results Direct Duplicate THIRD Units in:

External TLD QUARTER mR Rrdiotien Monitoring Systems

  1. 1 17.2 19.6 31.7
  1. 3 18.2 21.8 36.4
  1. 6 11.8 16.6 29.6 34.4
  1. 7 15.5
  1. 10 17.9 20.9 35.1 Control 30.1 28.8 37.3 FOURTH QUARTER
  1. 1 14.2 24.8 27.2
  1. 3 15.0 27.5 30.0
  1. 6 11.1 18.9 24.7 29.2
  1. 7 16.8
  1. 10 17.7

,25.2 30.4 Control 24.8 35.3 36.5 ANNUAL TOTAL

  1. 1 67 83 124
  1. 3 72 94 134
  1. 6 49 77 111
  1. 7 70 131
  1. 10 71 86.

129 Control 98 117 152 e