Text
.
gs creug hg UNITED STATES y,
g NUCLEAR REGULATORY COMMISSION
'li (
.. C WASHINGTON, D. C. 20555 os
/
COMMONWEALTH EDISON COMPANY AND IOWA-ILLIN0IS GAS D ELECTRIC COMPANY DOCKET NO. 50-254 QUAD CITIES STATION UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 67 License No. OPR-29 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by Commonwealth Edison Company (the licensee) dated September 27, 1977 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (il that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR.
Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifi-I cations as indicated in the attachment to this license amendment and paragraph 5 B of Facility License No. DPR-29 is hereby amended to read as follows:
i l
$tosoSb3/f
_2-B.
Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 67, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
/ _
iCo Thomas Ippolito, Chief Operating Reactors Branch #2 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance: April 20,1981 i
I
\\
l l
l
4 ATTACHMENT TO LICENSE AMENDMENT NO. 67 FACILITY OPERATING LICENSE NO. DPR-29 DOCKET NO. 50-254 Replace page 3.7/4.7-10 of the Appendix "A" Technical Specifications with the enclosed page.
O v-
.~e m.
,.,,,-.,._,,--.-e
,3,
,.w.._
.,..m
QUAD-CITIES
' DPR-29 r
reopened.
2) iThe main steamline. isolation. valves (one at a time) shall be veri-6ed for closure ~ time.
j
- d. At least twice per week the main
- steamline power-operated Isota-tion valves shall be exercised by partial closure and subsequent tcopening.
- 2. When 'an isolation valve listed in Ta-
- 2. In the event s'ny' isolation valve speci-ble 3.7-1 is inoperable, the position of f.ed in Tabte 3.7-1 becomes inopera-st least one other valve in each line ble. reactor power operation may con-
.having an inoperable valve shall be tinue provided at least one valve in recorded daily.
each line having an inoperab!c valve is in the mode corresponding to the iso-lated condition.
- 3. If Speci6 cations 3.7.D.! and 3.7.D.2 cannot be met, an orderly shutdown shall be initiated and the reactor shat!
g be in the cold shutdown condition I
within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
The temperature of the main steam-i 4.
line air pilot valves shall be less than 170* F except as specified in Specifi-cations 3.7.D.5 and 3.7.D.6 talovi.
- 5. F om and after the date that the tem-
~
perature of any main steamline air pilot va!ve is found to be greater ihan t
I 170* F. reactor operation is permissi-b:e only during the succeeding 7 days I
onless the temperature cf suela valve is sooner reduced to.! css than 10* F.
l provided the main steamline isofation valves are operable.
- 6. ITSpeci5 cation 3 7.D.5 cannot be met.
the main steamline isolation valve shall be considered inopernbie and action taken in accordance with Speci-
~
fication 3.7.D.2.
q l
a A
Amendment No. 67 3,7f a,j_ go
(("
UNITED STATES
~' %
NUCLEAR REGULATORY COMMISSION j,J, j
WASHINGTON, O. C. 20555 a
N...../
COMMONWEALTH EDISON COMPANY AND IOWA-ILLIN0IS GAS AND ELECTRIC COMPANY DOCKET NO. 50-265 QUAD CITIES UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment'No. 61 License No. OPR-30 1.
The Nuclear Regulatory Commission (the Comission) has found that:
A.
The application for amendment by the Comonwealth Edison Company (the licensee] dated September 27, 1977 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable ass'Jrance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; l
D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Speci-fications as indicated in the attachment to this license amendment and l
paragraph 3.8 of Facility License No. DPR-30 is hereby amended to read as follows:
i
. 3.B Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 61, are hereby incorporated in the license. The licensee shall operate the facility ir, accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY C0!911SSION
./
Ms.MQ Thomas M. Ippolito, Chief Operating Reactors Branch #2 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance: April 20,1981
,...n--.
..,,,,. ~ - - - - -,. -,
~
i
\\
ATTACHMENT TO LICENSE AMENDMENT NO. 61 FACILITY OPERATING LICENSE NO. OPR-30 DOCKET NO. 50-265 Replace page 3.7/4.7-10 of the Appendix "A" Technical Specifications with the enclosed page.
i t
r-,e------
m.
, m namn,s e,
m
., - --. ~ ~
e---m-vm.
n -<
--.-vv vs...,-n.
er,-r-e-mr.u--wm---r-
,,+-me-g-g-,
ww---mvp -nr em,,ww w-w-,,---,e
-p-o.,e.,-vm
s y-QUAD-CITIES DPR-30 r
reopened.
2)
%e main steamline isolation. vahes (one at a time) shall be veri-ficd for closure time.
- d. At least twice per week the main steamline power operated isofa.
tion valves shall be exercised by,
~
partial closure
- and subsequent reopemng.
=
- 2. 'In the event any isciation valve speci-
- 2. When an isolation valve listed in Ta-ble 3.7-1 is inoperable. the posidon or fied in Table 3.7-1 becomes inopera.
ble, reactor power operation may con-at least one other valve in each line tinue provided at least one valve in having an inoperable valve shall be
,each line having an inoperabic valve is reporded daily.
in the mode c'orresponding to the iso-lated condition.
t
- 3. If Specifications 3.7.D.I and 3.7.D.2 cannot be met. an orderly shutdown shall be initiated and th'c reactor shall be in thi cold shutdown condition O
within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
~
U
- 4. The temperature of the main steam-line air pilot valves sha!! be less than 170* F except as specified in Specifi-cations 3.7.D.5 and 3.7.D.6 below.
- 5. From and after the date that the tem-perature of'any main steamline air pilot valve is found to be greater than 170
- F, reactor operation is permissi-ble only during the succeeding 7 days unless the temperature orsuch valve is sooner reduced ta less than 170* F, provided the main steamline isolation valves are operable.
~
- 6. IfSpecification 3.7.D.5 cannot be met.
the main steamline isolation valve shall be considered inoperable and action taken in accordanu with Speci-fication 3.7.D.2.
7 y
Amendment No. 61 3.7/4.7-10