towa Electric Light and Ibwer Company hl April 24, 1981 d '"/.N2S/9$4.
DAEC-81-262 7
P \\ ** *- Q
'll q
Mr. James G.
Keppler, Director k-Office of Inspection and' Enforcement g
U.
S. Nuclear Regulatory Commission - Region III 799 Roosevelt Road Glen Ellyn, IL 60137
Subject:
Licensee Event Report No.80-012 UPDATE REPORT:
(14 day)
Previous ReporG Date 3-31-80 File:
A-ll8a
Dear Mr. Keppler:
In accordance with Appendix A to Operating License DPR-49, Technical Specifications and Bases for Duane Arnold Energy Center and Regulatory Guide 10.1, please find attached a copy of the subject Licensee Event Report.
(Total of 3 copies transmitted).
Very truly yours, fl Daniel L. Mineck Chief Engineer Duane Arnold Energy Center Docket 50-331 attachment DLM/MSR/pl e
cc:
Director, Office of Inspection and Enforcement (40)
U. S. Nuclear Regulatory Commission Washington, D.
C.
20555 Director, Management Information and Program Control (3)
U. S. Nuclear Regulatory Commission Washington, D.
C.
20555 U. S. Nuclear Regulatory Commission c/o Document Management Branch Washington, D. C.
20555 NRC Resident Inspector - DAEC s104 s oii 317
(
IJtww Anusis! Erw,gv Center
.2 O
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000331/LER-1980-011, Forwards Updated LER 80-011/01X-1 | Forwards Updated LER 80-011/01X-1 | | | 05000331/LER-1980-011-01, Lower Crankshaft Main Thrust Bearing Found Wiped on Thrust & Journal Surfaces During Annual Insp of Standby Diesel Generator 1G-21.Caused by Startups W/Low Oil in Lube Oil Sump.Bearing Replaced | Lower Crankshaft Main Thrust Bearing Found Wiped on Thrust & Journal Surfaces During Annual Insp of Standby Diesel Generator 1G-21.Caused by Startups W/Low Oil in Lube Oil Sump.Bearing Replaced | | | 05000331/LER-1980-012, Forwards Updated LER 80-012/01X-1 | Forwards Updated LER 80-012/01X-1 | | | 05000331/LER-1980-012-01, Standby Diesel Generator 1G-31 Lower Crankshaft Thrust Bearing 13 Was Found Wiped on Journal Surface.Caused by Bearing/Crankshaft Clearance Out of Spec & Low Oil Sump Level.Sump Filled.Bearing Replaced | Standby Diesel Generator 1G-31 Lower Crankshaft Thrust Bearing 13 Was Found Wiped on Journal Surface.Caused by Bearing/Crankshaft Clearance Out of Spec & Low Oil Sump Level.Sump Filled.Bearing Replaced | | | 05000331/LER-1980-036, Forwards Updated LER 80-036/03X-1 | Forwards Updated LER 80-036/03X-1 | | | 05000331/LER-1980-036-03, During Power Ascension Following Shutdown,Rod Block Monitor B Failed.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel. Protective Panel Installed Over Pins.Pin Connectors Seated | During Power Ascension Following Shutdown,Rod Block Monitor B Failed.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel. Protective Panel Installed Over Pins.Pin Connectors Seated | | | 05000331/LER-1980-044, Forwards Updated LER 80-044/03X-1 | Forwards Updated LER 80-044/03X-1 | | | 05000331/LER-1980-044-03, /03X-1:on 800824,rod Block Monitor B Began Indicating Downscale Causing Continuous Rod Withdrawal Block.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel.Connector Seated | /03X-1:on 800824,rod Block Monitor B Began Indicating Downscale Causing Continuous Rod Withdrawal Block.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel.Connector Seated | | | 05000331/LER-1980-045-03, Condensate Storage Tank a Low Level Switch LS-5218 Was Found Inoperable.Caused by Corrosion on Probe Leads Due to Moisture.Leads Dried, Cleaned & Reconnected | Condensate Storage Tank a Low Level Switch LS-5218 Was Found Inoperable.Caused by Corrosion on Probe Leads Due to Moisture.Leads Dried, Cleaned & Reconnected | | | 05000331/LER-1980-045, Forwards Updated LER 80-045/03X-1 | Forwards Updated LER 80-045/03X-1 | | | 05000331/LER-1980-054, Forwards Updated LER 80-054/01X-1 | Forwards Updated LER 80-054/01X-1 | | | 05000331/LER-1980-054-01, During Plant Startup, Leaking Relief Valve PSV-4405 Stuck Open Causing Reactor Scram.Cause Unknown.Pilot Assembly Replaced | During Plant Startup, Leaking Relief Valve PSV-4405 Stuck Open Causing Reactor Scram.Cause Unknown.Pilot Assembly Replaced | | | 05000331/LER-1980-055, Forwards LER 80-055/01T-0 | Forwards LER 80-055/01T-0 | | | 05000331/LER-1980-055-01, /01T-0:on 801110,main Steam Relief Valve Stuck Open Resulting in Rx Scram.Caused by Wiring Error During 1980 Design Change Work & Inadequate post-installation Testing.Error Corrected & Test Procedure Revised | /01T-0:on 801110,main Steam Relief Valve Stuck Open Resulting in Rx Scram.Caused by Wiring Error During 1980 Design Change Work & Inadequate post-installation Testing.Error Corrected & Test Procedure Revised | | | 05000331/LER-1980-065-03, During Surveillance Testing Suppression Chamber Purge Inlet Valve CV-4308 Would Not Cycle,As Required by Tech Spec 3.7.D.1.Caused by Sticking Operator Mfg by Miller Fluid Power | During Surveillance Testing Suppression Chamber Purge Inlet Valve CV-4308 Would Not Cycle,As Required by Tech Spec 3.7.D.1.Caused by Sticking Operator Mfg by Miller Fluid Power | | | 05000331/LER-1980-065, Forwards Updated LER 80-065/03X-1 | Forwards Updated LER 80-065/03X-1 | |
|