ML20003E320

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 81-07, Potential Problem W/Water-Soluble Purge Dam Matls Used During Inert Gas Welding. No Response Required
ML20003E320
Person / Time
Site: Satsop
Issue date: 03/16/1981
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Dobson D
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
References
NUDOCS 8104020875
Download: ML20003E320 (1)


Text

0 tror,,

bMb E bb

'o UNITED STATES

. 8',*

NUCLEAR REGULATORY COMMISSION g,.?

y REGION V 1990 N. CALIFORNI A BOULEVARD 0,

d'g SUITE 202, WALNUT CREEK PLAZA

  • ,,,e WALNUT CREEK, CALIFORNIA 94596 March 16, 1981 Docket Nos. 50-508, 50-509 e-

-Washington Public Power Supply System U

P.~ 0. Box 1223

( y,/,fa O-2 3 /Sg7 A $

Elma, Washington 98541 Attention: Mr. D. E. Dobson 8D'%

y p

Acting Program Director, WNP-3/5 Gentlemen:

to This'information notice is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE circular or bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, clo V

Enclosure:

IE Information Notice No. 81-07

.cc w/ enclosure:

M.' E. Witherspoon, WPPSS G. C. Sorensen, WPPSS f

1

-~

w e

"w-

b SSINS No.: 6835 Accession No.:

8011040267 IN 81-07 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 March 16, 1981 IE Information Notice No. 81-07:

POTENTIAL PROBLEM WITH WATER-S0LUBLE PURGE DAM MATERIALS USED DURING INERT GAS WELDING Description of Circumstances:

Recent experiences with water-soluble purge dam materials at several nuclear construction sites have shown the need to develop welding procedures that address the potential for thermally decomposing the purge dam material during inert gas welding or post-weld heat treatment operations. Specifically, polyvinyl alcohol film manufactured by Chris-Craft Industries was the purge dam material used at these construction sites.

The decomposition of this

_ urge dam material at elevated temperatures causes the material to lose p

its solubility in water. As a result, the purge dam material cannot be

-completely dissolved during subsequent piping system flushing and cleaning operations. The failure of this material to completely dissolve could cause significant problems-during reactor plant operation.

' Specimens of polyvinyl alcohol film were recently obtained from the Mono-Sol i Division of Chris-Craft Industries and tested at Franklin Research Center f(FRC) to determine,-among other things, the threshold temperature at which

the material becomes insoluble in water. The results of this test program
indicate.that (1) the' solubility of the purge dam material in water rapidly

~

approaches zero if the material.is heated and held at temperatures in excess of 300F;'(2) the-purge dam material hardens and becomes difficult to break if subjected to temperatures in the rangeLof 300F to 400F, and becomes brittle if heated;to 450F; and_'(3) purge' dam material heated above its threshold

temperature :is not soluble in commonly used laboratory solvents.

The inde-pendent testing laboratory (FRC) therefore concludes that the Mono-Sol poly-vinyl alcohol film will not dissolve during aqueous flushing of the system if the material has been heated to temperatures in excess of 300F.

Recommended Actions for Holder's of Operating Licenses and Construction Permits:

1

'It is recommended that all welding operations involving polyvinyl alcohol

. purge _ dam materials ~'be governed by procedures that require the material to

--be located in' areas' that are sufficiently-removed from heat so that the temperature of; the material does not reach 300F.

.No written response to this' information notice is required.

If you require

' additional information with regard _ to this subject, please contact the appropriate'NRC_ Regional Office.

Attachment:

Recently issued IE Information Notices

~

rv.,-J-a y-3.#-.,,

,.y-

-e.

-,,3 a

4 e

v,-

yw

Attachment IN 81-07 March 16, 1981 RECENTLY ISSUED IE INFORMATION NOTICES Information Date of Notice No.

Subject Issue Issued to 81-06 Failure of ITE Model 3/11/81 All power reactor K-600 Circuit Breaker facilities with an OL or CP 81-05 Degraded DC System at 3/13/81 All power reactor Palisades facilities with an OL or CP 81-04 Cracking in Main Steam 2/27/81 All power reactor Lines facilities with an OL 81-03'

. Checklist for Licensees 2/12/81 All power reactor Making Notifications of facilities with an Significant Events in OL Accordance with.10 CFR 50.72 81-02' Transportation of 1/23/81

'All Radiography Radiography Devices licensees 81-01 Possible Failures of-1/16/81 All power reactor General Electric-Type' facilities with an H.FA-Relays OL or CP.

80-45 Potential Failure of 12/17/80 All PWR facilities

-BWR Backup Manual Scram with an OL or CP Capability

.80 Actuation of ECCS in the 12/16/80

~ with an OL or CP All PWR facilities Recirculation Mode While in Hot Shutdown -

t80-43 Failures.of the Continuous

.12/5/80-All power reactor Water Level Monitor for

. facilities with an the Scram Discharge Volume OL or CP

.at Dresden Unit No. 2 80-42.

Effect of Radiation on 11/24/80-

-All power reactor

. Hydraulic Snubber Fluid facilities with an -

~ ~

0L or CP

' 0L = Operating Licenses

~ CP = Construction Permits

.