Requests Exemption from Completion Time Requirements of New Fire Protection Requirements.Facility Remains in Cold Shutdown Which Requires No Active Support for Active Core Cooling
ML20003D695
Person / Time
Site: Crane Constellation icon.png
Issue date: 03/24/1981
From: Hovey G
METROPOLITAN EDISON CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
LL2-81-0084, LL2-81-84, NUDOCS 8103300387
Download: ML20003D695 (3)


Text

.

e Metropohtan Edrson Comp ny Post Otfice Box 480 Il

"'1-

%ddletown. Pennsvivan,a 17057 L

Writer's Direct o ai Nurnber LL2-81-0084 / 'g;..'%

Lrch 24, 198k

\\

'j

[

d

( \\g eh

/L 4 h A g*

I

'l.

Division of Operating Reactors

' ~

Attn: Darrell G. Eisenhut, Director m

e

(%

'b,

  1. i U. S. Nuclear Regulatory Commission Washington, D.C.

20555 o.*

9.,

J

Dear Sir:

'N' '..g l b Three Mile Island Nuclear Station, Unit 2 (TMI-2)

Operating License No. DPR-73 Decket No. 50-320 10CFE50 Appendix R This letter is submitted subject to 10CFR50.48c6 concerning the recently implemented Appendix R Fire Protection Program requirements. Specifi-cally, with regards to Section III G, J, and 0 and open SER items, the licensee is requesting exemption from the cocpletien time requirements of 10CFR50.48c based on the following.

10C1150 Appendix R Section III G

" Fire Prctection of Safe Shutdown Capability" This section requires that " Fire protection features shall be provided for structures, systems and components important to safe shutdown." The TMI Unit 2 facility is currently and will remain in a cold shutdown conditicnfor some time to come.

Since the accident in March 1979, the Unit 2 facility has progressed to its present cold shutdown condition which requires no active support for adequate core cooling, i.e. maintenance of the cold shutdown condition. Passive heat removal via loss to ambient, if not used exclusively during recovery, will remain a viable option for core cooling until the eventual removal of the fuel from the core.

For this reason, coupled with the fact that the facility will not experience power levels during the recovery period such that Section III G(1)a could apply (Hot Shutdown), the licensee requests exemption from the requirement of the above referenced fire protection regulation for the remainder of the recovery mode, f

This request is made as provided for in 10CFR50.48c6 where

" required modification would not enhance fire protection safety

.5 in the facility.

10CFR50 Appendix R Section III J - Emergency Lighting The capacity of the existing emergency lighting units installed in the Unit 2 facility is acceptable per the SER.

In addition, f Cy gsg Mcow &scn Cwcn s a w cWm M c m S w

Darrell G. Eisenhut LL2-81-0084 the existing units satisfy the new Appendix R Section III J requirements. Therefore, no upgrading is required in Unit 2 to satisfy Appendix R Section III J except as may be necessary as a result of improvements resulting from Section III C modifications performed sometime af ter the recovery period.

10CFR50 Appen' dix R Section III O " Oil Collection System for Reactor Coolant Pump" This section requires that "the reactor coolant pump shall'be is not equipped with an oil collection system if the containment entered during normal operation." "Such collection systems shall be capable of collecting lube oil from all potential pressurized and unpressurized leakage sites in the reactor coolent pump lube oil systems."

As stated in regards.to Section III C above, the Unit 2 Facility is'in a cold shutdown mode requiring no active support, in this case reactor coolant pump (RCP) operation, for maintenance of proper decay heat removal.

Furthermore, the RCP's cannot be operated while the RCS parameters are so. low as to'not meet the RCP's minimum NPSH requirements.

- This condition will remain for the duration of the recovery mode.

Therefore, the licensee requests exemption.from the requirement of the 'above: regulation for the remainder of the recovery mode. This request is made as provided for in 10CFR50.48c6 where " required i

modification would not enhance fire protection safety in the

~

facility...".

Fire Protection Safety: Evaluation Report - Open Items

' Additional hose' stations and sprinklers. systems committed.to in the

-SER section noted below are incomplete as of the present time.

'Section 9 0 Auxiliary System-Paragraph 9.5 Fire. Protection Systems =

Subsections Fire Hose Stations Systems and.

- Automatic Water Sucoression in Diesel

Room Basement"

-_0 wing to the fact:that these open items originated from sa'e shutdown

~

1 concepts preceedingfAppendix R Section III G, the licensee believes the same reasoning expressed. relevant to'section G above applies.here

.also.;;Therefore the licensee requests _ exemption from the time limit W

"V

Darrell G. Eisenhut LL2-81-0084 requirements of 10CFR50.48c for the remainder of the recovery mode. This request is made as provided for in 10CFR50.48c6 where " required modification would not enhance fire protection safety in the facility...".

Sincerely,

[!

j G'.

K. Hovey Vice-President and Director, UtI-2 GKH:SDC:djb cc:

L. Barrett, Deputy Program Director Dr. B. J. Snyder, Program Director-DfI Office

.