REACTOR COOLANT SYSTEM SURVEILLANCE RE0VIREMENTS l
4.4.1.3.1 The required residual heat removal loop (s) shall be determined OPERABLE per Scecification 4.0.5, and by verifying that each residual heat removal pump develops a differential pressure of 3,112 psi on recirculation flow.
4.4.1.3.2 The required reactor coolant pump (s), if not in operation, shall be determined to be OPERABLE once per 7 days by verifying correct breaker r
alignments and indicated power availability.
l 4. 4.1. 3. 3 The required steam generator'(s) shall be determined OPERABLE by verifying secondary side level equivalent to 12% narrow range at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
\\
4.4.1.3.4 At least one coolant loop snall be verified to be in operation and circulating reactor cociant at least once per 12 nours.
l l
BEAVER VALLEY UNIT.1 3/4 4-2d DESIRED WORC'NG L810380 0$T
.