BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION in the Matter of

)

NEW YORK POWER AUTHORITY

)

Docket No. 50 333 4

James A. FitzPatrick Nuclear Power Plant

)

I A, PPUCATION FOR AMENDMENT TO OPERATING UCENSE Pursuant to Section 50.90 of the regulations of the Nuclear Regulatory Commission, the New York Power Authority, as holder of Facility Operating Ucense No. DPR 59, hereby appfles for an Amendment to the Technical Specifications contained in Appendix A of this license.

This application for an amendment to the James A. FitzPatrick Technical Specifications revises Note 16 to Table 3.1 1, " Reactor Protection System (SCRAM) Instrumentation Requirement," and Note 9 to Table 3.21, ' instrumentation That initiates Primary j

Containment Isolation," to allow the main steam line high radiation monitor trip level setpoint to be increased during Operating Cycle 10 to accommodate testing of the in-j core stress corrosion monitoring system.

i lne test involves incrementally increasing the hydrogen flow rates while monitoring the i

electrochemical potential and crack growth rate from modified low power range monitors In the core. The data col!ected from the test will provide the basis for establishing the l

amount of hydrogen needed to suppress crack growth of IGSCC susceptible material in the core. The addition of hydrogen reduces the concentration of oxygen in the coolant water and increases the Nitrogen 16 carryover in the steam. This results in a higher background radiation level seen by the main steam line radiation monitors.

]

The proposed changes to the Technical Specifications are Attachment I to this Application for Amendment to the Operating License. The Safety Evaluation for the proposed changes is included as Attachment ll.

NewYork Power Authority 1

hn,Brons Executive Vice President fuclear Generation i