Forwards Insp Repts 50-445/89-86 & 50-446/89-86 on 891206-900102 & Notice of Violation
ML19354D815
Person / Time
Site: Comanche Peak  
Issue date: 01/12/1990
From: Warnick R
Office of Nuclear Reactor Regulation
To: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML19354D816 List:
References
NUDOCS 9001220185
Download: ML19354D815 (4)


See also: IR 05000445/1989086

Text

i

-

_

LC (,

, +:

s;

h

In ReplyLRefer To:

JM I 21990

Dockets:-- 50-443/89-86

-

50-446/89-86

Mr.

W.-J.

Cahill,-Jr.

Executive Vice President

> TU Electric

400 North Olive Street, Lock Box 81

Dallas, Texas

-75201

-

Dear'Mr. Cahill:

,This refers to the inspection conducted by Messrs. W. D. Johnson,

S. D. Bitter,

M.-E.

Murphy, R.~V.

Azua, H. F. Bundy, and an NRC

_ consultant during the period December 6, 1989, through January 2,

1990, of activities authorized by NRC Construction Permits CPPR-126-

,

and CPPR-127 for-the Comanche Peak Steam Electric Station, Units 1

and-2, and to the discussion of our findings with you and members of

your staff at'the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined

during the inspection.

Within these areas, the inspection consisted

of selective examination of. procedures and representative records,

interviews with. personnel, and observation by the inspectors.

During'this inspection, it was found that certain of your activities

were.in violation of NRC requirements, as specified in the enclosed

. Notice of Violation.

A written response to this violation is

. required.

In accordance with 10 CFR 2.790 of the Commission's regulations, a

copy of-this letter, the enclosures, and your response to this

letter will be placed in the NRC Public Document Room.

The response. directed by this letter and by the accompanying Notice

,

is not- subject to the clearance procedures of the office of

Management and Badget as required by the Paperwork Reduction Act of

1980, PL 96-511.

Should.you have any questions concerning this inspection, we will be

pleased to discuss them with you.

Sincerely, ORIGINAL SIGNED 11Y R. F. V77RNICT

R. F. Warnick, Assistant Director

for Inspection Programs

Comanche Peak Project Division

Office of Nuclear Reactor Regulation

Enclosures:

See next page.

RI:CPPD:NRR

SRI:CPPD:NRR

DRS:TPS:R V

DRP:C R V

DRS:TP *R V

SBitter:ww,

WJohnson

MMurphy

RAzua

HBundy pfv-

1/tt 90

1 / 17 90

1/ G/90 7

1/ V)-/ 0

1/IA/9

9001220183 900112

/

iCPPD:N [ AD:CPPD:NRR

JWiebe

RWarnick RFM)

PDR

ADOCK 0500

y

g/

Q

'

1/lk/9

1/ tt./90

y

.

-

-,

.,

QtA

,

'

JAN I 21990

'

In Reply Refer Tor-

Docketst. 50-445/89-86

50-446/89-86

'

>

3

'

'

Oh

Mr. W. J. Cahill, Jr..

.

'

Y

ExecutiveLVice' President

TU Electric

!

'400 North olive Street, Lock Box 81

Dallas,cTexas

75201

>

' -

Dear Mr. Cahill:.

'This-refers to the inspection conducted by Messrs. W. D. Johnson,

S.~D.

Bitter, M. E.-Murphy, R. V.JAzua, H. F. Bundy, and an NRC

"

consultant during-the period December 6, 1989, through-January 2,

i

1990, of activities authorized by NRC Construction Permits CPPR-126

!

andiCPPR-127 for the Comanche Peak Steam Electric Station, Units 1

and'2, Land to the discussion of our findings with you and members of'

,

your; staff.at the conclusion of the' inspection.

r

'

.The enclosed copy ofcour inspection report identifies areas examined

'during the inspection.

Within these areas, the inspection consisted

of1 selective examination of procedures and representative records,

E

. interviews:with; personnel, and observation by.the inspectors.

l

0

During this: inspection, it was found that certain of your activities

l

n

were-in violation of NRC requirements, as specified-in the enclosed-

'

Notice of Violation.

A written response to this violation is

-required.-

JIn accordance with-10 CFR 2~790 of the Commission's regulations, a

.

' copy:of1this letter, the enclosures,-and your. response.to this

letter will be placed'in the NRC Public' Document Room.

.!

The response directed by this letter and by the accompanying Notice

is-not: subject to the clearance procedures of the office of

Management and Budget as required by the Paperwork Reduction Act of

'

.1980, PL 96-511.

l

Should you have any questions concerning this inspection, we will be

pleased to discuss them with you,

i

Sincerely,

R F WaudeA

R. F. Warnick, Assistant Director

for Inspection Programs

>

Comanche Peak Project Division

Office of Nuclear Reactor Regulation

Enclosures:

See next page.

l

-

>

.

. - - - - - .

-.

.

.

. - . . _ . .

,

W(

C.

<

._v

I

lW. J. Cahill, Jr.

-2-

JAN I 21990

'

= Enclosures: .

.

.

Appendix A

, Notice of-Violation

Appendix B - Inspection Report 50-445/89-86; 50-446/89-86

cc w/ enclosures:

. Roger D. Walker-

TU Electric

Manager, Nuclear Licensing

c/o Bethesda Licensing

TU Electric

3 Metro Center, Suite 610

Skyway Tower.

Bethesda, Maryland

20814

400 North Olive Street, L.B. 81

Dallas,-TX' 75201

E. F. Ottney

P. O. Box 1777

Juanita Ellis

Glen Rose, Texas

76043

President - CASE

1426 South Polk Street

Jack R. Newman

Dallas, TX ~75224

Newman & Holtzinger

,

1615 L Street, NW

Texas Radiation Control

Suite 1000

Program Director.

Washington, DC

20036

Texas Department.of Health

1100 West 49th' Street

George R. Bynog

Austin,_ Texas

78756

Program Mgr./ Chief Inspector

Texas Dept. of Labor & Standards-

GDS Associates, Inc.

Boiler Division

1850 Parkway Place, Suite 720

P.O. Box 12157, Capitol Station

Marietta, GA . 30067-8237

Austin, Texas

78711

Honorable George Crump

County Judge

Glen' Rose, Texas

76043

Ms.. Billie Pirner Garde, Esq.

Robinson, Robinson, et al.

103 East. College Avenue

Appleton,_WI

54911

Regional Administrator, Region IV

U.S. Nuclear Regulatory Commission

611 Ryan Plaza Drive, Suite 1000

Arlington, Texas

76011

' William A. Burchette, Esq.

Counsel for Tex-La Electric

Cooperative of Texas

Heron, Burchette,-Ruckert & Rothwell

1025 Thomas Jefferson St., NW

Washington, DC- 20007

'

-

. _ _ _

_

g; q); ; 3 ' ~<

> -

__

s.

,

, Q

'%

50-445/pfL/$; 50-446/f9-ff

~

-

DISTRIBUTION:

l@$6isififiFlie?t 50:445/446')?y'"

N R C " P DR " ~"""" """"""""""

LPDR

.CPPD-LA.

-

CPPD_ Reading (HQ)

ADSP

Reading

  • Site: Reading File

.

'

  • R. Warnick
  • J. Wiebe
  • H.

Livermore:

. MIS. System, RIV

-

  • RSTS Operator, RIVl

RPB, RIV.

.RIV Docket File'

-

J._Gilliland, RIV

,

  • L.

Shea, ARM /LFMB

C..I.-Grimes

'J..H. Wilson

J. Lyons-

M. Malloy

r

J. Moore, OGC_

<

M. Fields'

D.'Crutchfield

.

!

T. Quay

.

E.' Jordan

B.-' Grimes

L

B. Hayes

l'

'C.'Vandenburgh

L-

-J.

Partlow

'

  • w/766

l

l

I

l

!

t

-

-

- . . ,