ML19352A823
| ML19352A823 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 03/23/1981 |
| From: | Brunner E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Kay J YANKEE ATOMIC ELECTRIC CO. |
| Shared Package | |
| ML19352A820 | List: |
| References | |
| NUDOCS 8106020185 | |
| Download: ML19352A823 (2) | |
See also: IR 05000029/1981002
Text
-
-
-
.
g#
(4,
UNITED STATES
}
\\/ ' J'.-
.
- 4
NUCLEAR REGULATORY COMMISSION
(
- (
E[,
Ef
o-
REGION I
'
631PA K AVENUE
f
qffg
muc oP Paussia, nsusvt. vama mas
+....
Docket No.'50-29
23E
Yankee Atomic Electric Company
ATTN: Mr. James A. Kay
Senior Engineer - Licensing
1671 Worcester Road
Framingham, Massachusetts 01701
"
Gentlemen:
Subject:
Inspection 50-29/81-02
This refers to the routine safety inspection conducted by Mr. T. Foley of this
'
office on January 1-31, 1981 at Yankee Rowe Power Station (Yankee Rowe), Rowe,
.
Massachusetts of activities authorized by NRC License No. DPR-3 and to the
discussions of our findings held by Mr. T. Foley with Mr. H. Autio of your staff
at the conclusion of the inspection.
Areas examined during this inspection are described in the Office of Inspection
.
and Enforcement Inspection Report which is enclosed with this letter. Within
these areas, the inspection consisted of selective examinatiotis of procedures
and representative records, interviews with personnel, and observations by the
inspector.
.
Our inspector also verified the steps you have taken to correct the items of
-
noncompliance brought to your attention in the enclosure to our letter dated
1
September 20, 1979. We have no further questions regarding the steps you took
to correct Items A and C.
Based on the results ~of this inspection, it appears that one of your activities
was not conducted in full compliance with NRC requirements, as set forth in the
Notice of Violation, enclosed herewith as Appendix A.
This item of noncompliance
has been categorized into the levels described in the Federal Register "otice
i
(45 FR 66754) dated October 7, 1980.
You are required to respond to nis letter
1
and in preparing your response, you should follow the instructions in Appendix
A.
.
!
In accordance.with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title
'
10, Code of Federal Regulations, a copy of this letter and the enclosures will
,
be placed in .the NRC's Public Document Room.
If this report contains any information
that you (or your contractor) believe to be proprietary, it is necessary that
,
,
I
)
8106 0 20 l75 t
_
- .
.---
_
-.
. -
-
. . - -
. - - - .
,-
.
.
.
, Yankee Atomic Electric
2
MAR 2 31981
Company
you make a written application within 20 days to this office to withhold such
<
information from public disclosure. Any such application must be accompanied by
-an affidavit executed by the owner of the information, which identifies the-
document or part sought to be withheld, and which contains a statement of reasons
which addresses with specificity the items which will be considered by the
Commission as listed in subparagraph (b) (4) of Section 2.790.
The information
'
sought to be withheld shall be incorporated as far as possible into a separate
-
part of the affidavit.
If we do not hear from you in this regard within the
specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased
to discuss them with you.
Sincerely.
[
- -
.4
_
E do
0. Brunner, Chief. Projects
t
Br ch #1, Division of Resident
,
d Project Inspection
Enclosures:
1.
Appendix A, Notice of Violation
2.
Office of Inspection and Enforcement Inspection
Report Number 50-29/81-32
cc w/er '.,:
H. Autia, Plant Superintendeat
J. E. Tribble, President
.
k
5