05000334/LER-1980-107-03, /03L-0:on 801206,electrolyte for Detectors 101A & 101B Found Not Dripping.Caused by Clogged Wick & Glass Orifice.Wick & Orifice Cleaned & Top Vent Filter Loosened

From kanterella
(Redirected from ML19351F529)
Jump to navigation Jump to search
/03L-0:on 801206,electrolyte for Detectors 101A & 101B Found Not Dripping.Caused by Clogged Wick & Glass Orifice.Wick & Orifice Cleaned & Top Vent Filter Loosened
ML19351F529
Person / Time
Site: Beaver Valley
Issue date: 01/05/1981
From: Lacey W
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19351F522 List:
References
LER-80-107-03L, LER-80-107-3L, NUDOCS 8101130432
Download: ML19351F529 (2)


LER-1980-107, /03L-0:on 801206,electrolyte for Detectors 101A & 101B Found Not Dripping.Caused by Clogged Wick & Glass Orifice.Wick & Orifice Cleaned & Top Vent Filter Loosened
Event date:
Report date:
3341980107R03 - NRC Website

text

Nac POnee ses u. s. NuctE An gErutAT:nv COnaneisssoN a.rn LICENSEE EVENT REPORT O

CoNinot eLOCx: l l

l l

1 l

l intEAss eniNr Oa tvet att cE:vixEo iNr :uAri:N) l ? l ^ l 3 lV l S l 1 l@l 0 l0 l-l 0 l0 l0 l0 l0 l-l0 l0 l@[4 l111 l1 l1 l@lse car w @

l l

o i e e ucausas coce is is uca~ss =uuna a

a uca=>s tves ao CON'T L2.L' l "Y l L @l 015 l 0 l 0 l0 l 3 l 3 l a l@l 112 I o l 61 al 0)@l0 l1 ln 15 la l1 l@

ou 8

80 el cocKErNuwetR e8 et tvtNr oArt 34 is atPoRr oArt 80 EVENT DESCRIPTION AND PROeAeLE CONSEQUENCES bio g o 121 l t.*hile conducting a redundant channer check for removal from service of the 101C it was discovered that the 101A and 101B; g l chlorine detector for surveillance testing, g [ detectors' electrolyte was not dripping.

Both detectors were declared out of l

[oTT'l I service and the 101A detector was tripped. The Control Room Ventilation System was g g i isolated from outside air in accordance with Technical Specification 3.3.3.7.

This l IoTTl I w1s the eighth failure of this type at BVPS.

l o a i l

ao ee sus "o'o'E N

YoE su$cEs CouponaNr Coof s

E t,ojp]

i s I c l@ La J@ La J@ I t l x i s I T I n l u i@ i t l@ tz.j g io i,

u u

i, a

sEcutNrtAL OCCURRENCE REPomr PEvisioM LE R/Ro (VENr YEAn REPoRrNo.

CooE TYPE No.

O,AEg I a l 01 L--!

11I0171

.W loI3I W

l--I 6

21 22 23 24 26 27 28 29 30 JS 32

  1. Se*=irrE e6EUs. *'uY$eI' iNsTEa'e=

Na" EEN c'= !i.aTr

    • S$"

wouas 22 s

s w

gg l2Nl@ W@

l ti l 0 l 2 15 l@

%lJ4Fl@

( Z,,_j@

lZl@

l0l0l0l l

33 3s 38 37 40 48 4

43 44 47 CAUSE OESCRIPTION ANO CORRECTIVE ACTIONS @

l i g o l l The fluid tank was dauer a slight vacuum and the wick and glass orifice were i

i i l cloeged. The wick and orifice were cleaned and the top vent filter was loosened.

l 1 Engineering has been requested to evaluate this system due to the repeated l

. 2 l

g I failures.

l mI I

so 7

s s ofwensrArus h "isEoEv' Prion @

's'r*A h'E seowen oiscoveny ossCn:

W l Fl@ l 0l 7 l 5l@l N/A l

W @l Redundant channel check l

A!nviry canNr A ov~re, Activiry @ I i.ocAno.o, num @

nu.seo o, asuns.

n/A I

N/A I

I z l @ L.zJ@l i s 7

8 9 10 it 44 46 30 PtAsoNNEL f xPosuREs Nupets rYPE cEsCmiPrioM Lo_1 o I o l@l z l@l x/^

l

.so~~.L%u'.'ies oescaiPno=h wuwe<=

l010l0l@l N/A l

i 4 7

8 9 at 12 80

'rEs # " s s*c"a'[r5c' '" h fiTil Lz_l@l N/A 1

P S 9 50 80 l,l L.J L. N [@oascaiPrioN @

NRC USE ONW

.ssue l

N/A I

IIIIIIIIIIIIIi i.

o.:

l A

~

~

U Y l

NAME OF PREPARER PHONE:

=

t l

l 8 1 0: 3 7 3 (iM.

s i

i 1

t t

f Attachment To LER 80-107/03L Beaver Valley Power Station

{

j Duquesne Light Company I

]

Docket No. 50-334 l

l 1

No further information is available or needed to satisfy the reporting i

requirement.

I i

J l

i I

a, t

1

?

i t

i i

1 1

}

1 1

1 l

i e

1 l

i 1

l l

i l

1 e

l I-e

--rw-evme,-,,-"T*=g'"m+-*1

  • *
  • T F* w e M t v-MM ~ ~ + we M* * * + *w w vvwew*e'***wm*--*'sev'N-+-*-t-**N+~-***-e"'*-

ew--m'*

r'*-"**'******-****

a