ML19351F288

From kanterella
Jump to navigation Jump to search
Environ Dose Pathway Study, Spring 1979 Through Summer 1980
ML19351F288
Person / Time
Site: Quad Cities  
Issue date: 12/30/1980
From:
EBERLINE INSTRUMENT CORP.
To:
Shared Package
ML19351F286 List:
References
NUDOCS 8101120156
Download: ML19351F288 (44)


Text

O ENVIRONMENTAL DOSE PATHWAY STUDY QUAD CITIES STATION Spring 1979 through Summer 1980 l

4

i 4

l 4

i DECEMBER 1980 5

l l

Submitted by Eberline Instrument Corporation Midwest Facility 245 Roosevcit Road West Chicar, Illinois i

I i.

1

m-Table of Contents Page Section I External Dose Study 1

Section II Iodine-131 in Milk 20 Section III Aquatic Pathway Study 25 Section IV Source Term Study 28 Appendix 30

SUMMARY

In 1979-1980, the Commonwealth Edison Company continued their Environs mental Dose Pathway Studies at Quad Cities Station.

This study was designed o add knowledge in the following areas:

(1) The exposure from airborne noble gases at levels below 10mR/yr; (2) The concentration of I-131 in mit. relative to the predictive model of Regulatory Guide 1.109; (3) The concentration of certain radionuclides in fish relative to the RG 1.109 predictive model; and (4) The source term of the lesser radionuclides such as the transuranics.

The results of-studies 1 and 2 are believed to provide useful information and indicate that the RG 1.109 models for noble gas exposure and I-131 in milk are accurate within a factor of two or better.

The validity of the RG 1.109 models for radionuclides in fish (study area 3) remain unproven because the concentrations of plant released radioactivity in fish are too small to be detected, even with the sensitive techniques used herein.

It is doubtful that this particular model will ever be confirmed at a nuclear power station because so little radioactivity is released from there to the aquatic environment. The Quad Cities study of the lesser radionuclides (Study 4) was not conducted due to scheduling difficulties.

e

Section I QUAD CITIES EDPS - EXTERNAL DOSE STUDY (1979-1980)

I.

Introduction The Quad Cities Nuclear Power Station is located on the east bank the Mississippi River, four miles of Cordova, Illinois.

Units 1 and 2, tach an 800-MWe boiling water reactor release airborne effluents such as noble gases and radioiodine to the atmosphere from two locations:

a 94-meter chimney located just west of the building complex and a 50-meter vent stack near the center of the compics. The height of the reactor building is 44 m; the combined cross-sectional area of the 2

reactor and turbine buildings is 2840 m,

The main source of population exposure near nuclear power stations, has been gamma radiation from radioactive noble gases. The doses, which are calculated from effluent measurements on the basis of dispersion models (RG 1.109), decrease rapidly as a function of distance from the point of release. Doses have been measured at several installations in the course of special studies, but routine environmental monitoring programs usually report "less than" values because the doses are exceeded by,the naturdi, background radiation.

Even fluctuations in the natural radiation beckground can be of the same magnitude as the dose from air-borne effluents.

The purpose of the study was to test a procedure for determining external radiation exposure from airborne effluent throughout the area around the station with reasonable effort and cost at levels of 10 mR/ year and less.

The system consisted of TLD's'placed at 16 locations near the station perimeter for measuring the total exposure for,3-month periods, two pressurized argon ionization chambers (PIC's) for distinguishing between the natural radiation background and-radiation exposure from air-borne effluent, and periodic survey meter readings with a detector sensitive at the pR/hr level at the 16' locations to determine radiation background differences among them. Comparison of measured with computed exposures from airborne effluent at these' locations can then be used to calibrate the computational model for predicting exposures at more distant locations.

l*

II.

Study Plan f

In the 1979-1980 period, Quad Cities Station was ringed by 16 dosimetric l

measurement locations at'or near the site boundary in the directions used l

for dispersion calculations (Figure 1 and Table 1).

Two of the locations (H and E), in approximately opposite directions, had Pressurized Ioniza-tion Chambers (PIC's) for continuously reading (by 10-second integrations) the gamma-ray exposure rate..Thermoluminesc >nt dosimeters (5 per station) were placed at all stations for 3-month exposure integrations. A field l

technician measur'ed the instantaneous background radiation exposure with a scintillation survey meter calibrated relative to the PICS, at each.

location, at 2-week intervals, and ' serviced the PICS. Thus the natural i

l 1

l L

II.

Study Plan (continued) radiation background was recorded continuously (except when the noble gas plume was nearby) by the PICS at two locations, and fortnightly at the other 14 locations.

Interpolations based on these two sets of measure-ments will yield the background exposure of the TLDs.

A.

Plc Program Pressurized Ionization Chambers manufactured by Reuter-Stokes, model RSS-111, were used in this program. The RSS-111 Environmental Radiation Monitor is a complete ultra-sensitive gamma exposure monitoring system designed to measure and record the low level exposure rates such as those due to fallout and natural background radiation. The RSS-Ill is housed in two cable-connected weather-proof enclosures (Figure 2).

The sensor housing contains a high pressure spherical ionization chamber with direct mounting to a solid state electrometer. The control housing contains the readout device. The spherical ionization chamber is filled to a pressure of 25 atmospheres (absolute) with ultra-purity argon. When radiation is incident upon the chamber, the ion pairs produced in the active volume are swept to the electrodes by a collecting potential. The resulting current is measured by an electrometer and can be related directly to the frec air exposure rate.

The PICS provide numerous data points to record the exposure rate, so that precise distinctions can be made between the natural hackground continuum and periodic lucreases due to station effluents.

The background varies gradually at a given location because of the changing accumulation of radon daughters in the ground near the surface and in the ground level air, and because of changes in uhleiding by snow, rain, and vegetation against radiation emitted by radionuclides in the soil and rock.

Changes in the background value observed with the PICS provides adjustments for the background values determined fortnightly with the survey instrument. The survey meter consists of a 2" x 2" NaI (TI) crystal shielded with cadmium to minimize response to energies below about 80 kev. The system yields a count rate of about 4000 counts per minute when the pressur-Ized ion chamber indicates a dose rate of about 8 pR/hr. The gamma readings, with adequate intercalibration with the PIC, will provide additional information on the natural background dose rate at the TLD stations and may therefore enable measurement of doses due to station releases at these locations to be calculated.

The computer-processed PIC data consisted of, on an hour-by-hour l

basis, the average total exposure rate (gR/hr), the standard deviation of the average, the measured (or assumed) background, and the estim-ated plume contributions to the total exposure rate (the difference between the total and background).

(An " assumed" background rate is the last total exposure rate measured without a plume present. A plume was considered present if the total exposure rate exceeded by 3a of the background.

The hourly plume contributions were summed to.give the monthly measured total. This total was then compared to calculated exposure rates computed with accepted sector-averaged dispersion models (RG 1 109) and station reported gross radioactivity levels.

2 L.

II.

Study Plan (continued)

The PIC readings _ are based on calibration by the manuf acturer.

The calibration is in terms of Ra-226. The radiation exposure response is energy dependent:

it is within 3 percent of the Ra-226 value from 0.5 to 2.5 MeV, but the response factor is higher above 2.5 and below 0.5 MeV, especially at 0.1 MeV. The PIC does not detect external alpha and beta particles or gamma rays below 0.06 MeV.

9 e

W 3

TABLE 1 QUAD CITIES E.D.P.S. MONITORING LOCATIONS Site Sector Direction Range Location (miles)

A N

5.5 0.7 On the section line post behind the post box with two wheels on it, in the bushes.

B NNE 25 1.3 After the curve right side of the road on the warning sign telephone post.

C NE 44.5 1.7 On the fence at Nitrin air sampler.

D ENE 68 1.0 On the #3 yellow warning sign post between the road (84) and RR track.

E E

85.5 0.8 On the fourth pole after the road to the station, on right side of Ill 84 going south (a PIC location).

F ESE 113 0.7 On the tenth pole after the road to the station on right side of Ill 84 going south.

G SE 137 0.8 On the eighteenth pole after the road to the station on right side of Ill 84 going south.

H SSE 160 0.8 On the pole with meter on the bottom right side of the road (a PIC location).

I S

174 0.8 on the fence by the pole and telephone post.

J SSW 212 2.5 In the area shown in the map.

K SW 226 2.6 On on of the signs by R.R. track.

L WSW 248 2.1 On the sign postl (--->l.

M W

265 2.0 On the'" shot gun shells only" sign post.

N WNW 294 2.5 Area shown on the map around the bridge.

O NW 317 2.5 Along the side route 67 at road to Shaffton Cemetery.

P NNW 334 1.9 On the fence at Hanson's boat landing air sampler.

4

FIGung, '

OM' TORINa LO Q

' i ' l ' 'if,flV'/

/

6,i o

n n

@p:e)//

/c r

6 5

i. x 75f,,

/

a i/

J

/

'l

/!i, t)

=

Y

,/'/

/

I

/',? l;'l-i c

,x f

vN q,/ "

7, S '

I'/

'r, [

' V,(/,/

/

x pI

'I J ili i

/

i S

[

5 e

n iL h

y re tneC re b

ma hC e

n n

o i.

ita b

iz m

n u

lo da P

e g U

Hin y

su T

ro o E

snH S

e S

TU O

DA E

R D

l g

on N

NA ri t s nu oo R

CH O

T C

E TE D

2 e

rug i

F re td r

r a o h c Ce R

\\

II.

Study Plan (continued)

B.

Thermoluminiseerf. Dosimeter Readings Lithium Fluoride thermoluminiscent dosimeters (TLDs) were emplaced at 16 locations surrounding the plant, approxi-mately one location per sector used for dose calculations.

Locations are given in Table 1 and Figure 1.

TLD badges remained on station for three months.

Exposure rates were measured and compared with thosecalculated from release and meteorological data, gamma survey data (see Section C), and where possible, from PIC data (see Section A).

The Polyethylene Shield in Polyethylene Vial (-56 mg/cm ) and 2

PVC sphere isotropic holders ( 1 cm/cm ) were chosen for the period 2

of September 23, 1979, through November 15, 1980.

The TLDs are calibrated at frequent intervals and are found to be accurate within a standard deviation of 110%.

C.

Survey (gamma) Mete'r Reddings Gamma survey readings were made at. each of. the TLD stations on alternate weeks using a survey meter with a 2" x 2" NaI (TI) crystal and a discriminator set to climinate detection of gamma radiation below 80 kev. The results are summarized in Section III-C. The table shows the conversion factor used to relate counts per,ninute (survey meter) to uR/hr for each location III.

Results A.

PIC Data

  • Because of the operational difficulties with the PICS, useful data were not collected until October 1979.

Data collection continued until June 1980.

The following table shows the meascred vs. estimated cumulated gamma dose (estimated cumulative gamma dose _provided by Murray and Trettel '

Inc.,' based oIn the actual nobic gas release.information, actual site meteor-ology and RG 1.109 atmospheric dispersion and dose calculation model.) for the 4th Quarter 1979, 1st Quarter 1980 and 2nd Quarter 1980.

(Dose uR)

Site E Site H Measured Estimated Measured

-Estimated 4th Quarter 1979 451 180 150

-150 1st Quarter 1980 185 60 37 60 2nd Quarter 1980 NA 100 NA 90

  • The PICS were' calibrated by the manufacturer and as discussed later

~

in-the text, may measure high by a factor of 1.2 when compared.to LiF TLDs encapsulated in PVC Isotropic spherical holders (-1 gm/cm ),

2 7-

. - ~. -

T 1

r i

j

/

i i

i 1

Table 2 4

l Gross Radioactivity Release Rates (mci /sec)*

l 4

1 l

4th Quarter 1979 1.05 1st Quarter 1980 0.46 l

2nd Quarter 1980 0.74 i

{

  • An assumed average gamma energy of 0.8 MeV and no radiological i

decay were used in the calculation.

i l

I 8-p.

. -. -., _. ~., _ _ _,. -..... - _.. _... -..,

,.._,...,..._--,4-..

<4..

III-A.

PIC Data (continued)

Table 2 shows the gross radioactivity release rates for the period October 1979 - June 1980. Tables 3-A and 3-B summarize the PIC data on' a weekly basis for the period October 1979 - August 1980. Table 4 summarizes the PIC background data for the same period of time.

1 B.

Thermoluminiscent Dosimeter and Camma Survey Data Table 5 summarizes the data, on comparison of dose with TLDs in various packing mate' rials from Dresden EDPS Report (1979). At Dresden five different packing materiale were tested for the effect on the TLD response to natural and. noble gas radiation. At Quad Cities only two types of packaging materials were tested--one used by CECO for' environ-mental monitoring and th'e isotropic sphere developed by Eberline Instrument Corporation.

t The TLD packings Polyethylene Shield in polyethylene vial 2 thickness) thickness),'and Isotropic PVC holder ( 1 g/cm

( 56 mg/cm2 were chosen for the study.

Tables 6 and 7 summarize the Gamma-Dose Rates' measured using TLDs from September 23, 1979, to November 15, 1980.

Comparison of TLD data with PIC data is presented in Table 9 From this the correction factors rre obtained to correlate TLD and PIC data.

Table 10 presents the background data obtained from PIC and y-survey measurements. The y-survey readings were converted to uR/hr, using a calibration curve between y cpm and PIC UR/hr (Table 8).

Table 11 presents the average background from y-survey readings for all locations.

l I

e

(

9

III-A.

PIC Data (continued)

Table 3-A Summary of PIC Data from September 1979 - June 1980 ON-SITE #2 LOCATION - E (weekly average)

EpR Ave pR/hr Dates Hours Gross Bhgd Total Bkgd Net 09/09/79-09/22/79*

322 2294 2274 7.12 7.06 0.06 10/06/79-10/13/79 171 1249 1218 7.30 7.12 0.18 10/13/79-10/20/79 162 1211 1167 7.48 7.20 0.28 10/20/79-10/27/79 172 1244 1194 7.25 6.96 0.29 10/27/79-11/03/79 171 1283 1229 7.50 7.19 0.31 11/04/79-11/10/79*

147 1033 1007 7.03 6.85 0.18 11/17/79-11/23/79*

144 1178 1031 8.18 7.16 1.02 11/30/79-12/01/79 214 1668 1543 7.79 7.21 0.58 12/01/79-12/08/79*

165 1186 1160 7.19 7.03 0.16 12/29/79-01/05/80 164 1291 1139 7.87 6.95 0.92 01/05/80-01/12/80*

168 1226 1193 7.30 7.10 0.20 01/26/80-02/03/80*

188 1278 1277 6.80 6.79 0.01 02/23/80-03/02/80 251 1279 1270 5.09 5.06 0.03 03/02/80-03/08/80*

135 820 832 6.07 6.16

-0.09 04/12/80-04/19/80*

218 1158 1153 5.31 5.29 0.02 04/28/80-05/06/80*

252 1391 1383 5.52 5.49 0.03 06/06/80-06/10/80*

103 736 700 7.17 6.82 0.35 06/23/80-06/27/80 130 749 726 5.76 5.58 0.18

  • Data were not available in between periods.

I I

10

III-A.

PIC Data (continued)

Table 3-B Summary of PIC Data from September 1979 - August 1980 ON-SITE #1 LOCATION - H (weekly Average) ipr u

Dates Hours Gross Bkgd Total Bkgd Net 09/09/79-09/23/79 317 2338 2221 7.38 7.01 0.27 09/23/79-10/06/79 311 2285 2197 7.35 7.06 0.29 10/06/79-10/13/79 167 1163 1155 6.96 6.92 0.04 10/13/79-10/20/79 159 1134 1104 7.13 6.94 0.19 10/20/79-10/27/79*

174 1192 1153 6.85 6.63 0.22 11/04/79-11/10/79*

144 996 965 6.92 6.70 0.22 11/17/79-11/23/79 143 1029 979 7.20 6.85 0.35 11/23/79-12/01/79*

192 1307 1297 6.81 6.76 0.05 12/08/79-12/15/79*

172 1155 1151 6.72 6.69 0.03 12/29/79-01/05/8 0 165 1108 1103 6.72 6.68 0.04 01/05/80-01/12/80*

169 1184 1147 7.01 6.79 0.22 03/29/80-04/05/80*

170 1054 1075 6.21 6.34

-0.13 04/28/80-05/06/80*

196 1203 1308 6.14 6.67

-0.53 06/06/80-06/14/8CP 184 1230 1201 6.68 6.53 0.15 07/18/80-07/25/80*

175 1073 1136 6.13 6.49

-0.36 08/16/80-08/23/80.

4161 1099 1060 6.83 6.58 0.25 08/23/80-08/30/80 204 1132 1131 5.55 5.54 0.01 08/30/80-09/06/80 204 1106 1052 5.02 5 16 0.26

  • Data were not available in between periods.

i 11 i

III-A.

PIC Data (continued)

Table 4 Summary of PIC Background Date uR/hr (integrated over 4-week intervals)

Site E Site H 1979 October 7.38 6.98 November 7.61 6.98 December 7.49 6.72 1980 January 7.32 6.87 February March 5.49 6.18 April

""Y 6.1's June Table 5*

Dose Rates in pR/'..- (April 26 - May 19, 1978)

Packaging Material Locations (tlo)

A B

F H

Al Shield, PVC holder 8.4010.43 7.27 0.24 7.37 0.34 7.84 0.17 Al Shield, Polyethylene holder 8.67 0.35 7.0010.44 7.39!0.26 8.19 0.67 Polyethylene Shield, PVC holder 9.88!0.17 9.36!0.35' 9.40 0.29 Polyethylene Shield, Polyethylene Vial holder 9.4510.75 Isotropic PVC Sphere 7.6910.26 6.2410.29 6.27 0.22 6.67!0.61

  • Previously reported Dresden Station data (1979).

i i

l i

E I

i l

12 L

Thetmo_luminiscent D'simeter and Gamma Survey Data (continued)

III-B.

o Table 6 Average Environmental Gamma Dose Rates using TLD's in pR/hr (!1o)

  • 2 (Polyethylene chield in Polyethylene vial holder - 56 mg/cm thickness).

Station 23 Sept 79--3 F eb 80 3 Feb 80--11 June 80 11 June 80--15 Nov 80 A

8.5!0.5 6.6!0.6 8.3!0.1 B

7.520.3 6.4 0.4 6.7!0.2 C

6.6!0.3 6.5!0.3 6.4!0.4 D

7.2!0.5 6.5 0.7 8.1!0.4 E

6.9!0.5 5.710.4 6.4 0.2 F

7.2!0.8 5.8!0.6 6.6!0.6 C

7.210.5 6.0!0.3 6.811.4 H

7.510.8 6.420.2 8.410.3 I

6.3!0.3 5.7 0.5 8.5!0.3 J

7.2!0.3 Missing Missing K

6.6!0.5 6.1 0.5 8.5 0.3 L

6.9!0.3 -

5.8!0.7 8.0 0.6 M

7.5!0.3 Missing 7.5!0.6 N

7.2!0.5 6.8!0.8 7.9!0.2 0

8.5!0.6 7.0!0.2 8.010.2 P-7.8!0.5 Missing 8.6!0.3

  • Standard deviation la is usually based on five replicate LiF TLD chip readings.

t 13

III-B.

Thermoluminiscent Dosimeter and Gamma Survey Data (continued)

Table 7 Average Environmental Gamma Dose Rates using TLD's in UR/hr (!10)*

(Isotropic PVC Sphere holder

.1 g/cm2 thickness)

Station 23 Sept 79--3 Feb 80 3 Feb.80--11 June 80 11 June 80--15 Nov 80 A

6.3!0.3 5.4!0.4 6.6!0.6 B

6.6!0.6 5.7!0.2 6.4!0.2 C

6.0!0.3 5.1!0.4 6.2!0.8 D

6.3!0.5 5.3!0.2 6.0!0.1 E

6.0!0.3 4.9!0.1 5.7 0.2 F

6.3!0.3 5.3!0.2 5.9!0.2 G

5.6!0.3 4.7!0.3 5.7!0.3 H

6.0!0.3 5.3!0.5 6.4 0.2 I

5.6!0.3 5.2!0.4 5.5 0.1 J

6.3!0.3 Missing Missing K

6.0!0.8 5.1!0.5 6.6 0.6 L

6.3!0.3 5.6!0.6 6.5!0.2 M

6.6!0.3 5.8!0.4 Missing N

6.310.6 5.5!0.3 7.2!0.2 0

7.2!0.3 6.4 0.2 7.1!0.6 P

6.9t0.6 6.4+0.4 7.1!0.2 The comparison of TLD and PIC data (Table 9) is in good agreement with previously reported results from the 1979 Dresden EDPS program.

The PIC and Na1 Gamma Survey data (Table 10) are in good agreement.

It also indicates that the two systems (PIC and Nal) are well cross-calibrated.

  • Standard deviation lo is usually based on five ceplicate LiF TLD chip
readings, d

14

III-B.

Thermoluminiscent Dosimeter and Gamma Survey Data,(continued)

Table 8.

Conversion Factor to Calculate UR/hr from Counts per Minute (Survey Meter Reading) at Sites A through B Site

  • pR/hr =

A 1.11 x 10-4 (cpm)'+ 6.37 B

1.14 x 10-4 (cpm) + 6.36 C

1.12 x 10-0 (cpm) + 6.16 1.09 x 10-4 (cpm) + 7.27 D

1.11 x 10-4 (cpm) + 6.98 E

F 1.07 x 10-4 (cpm) + 6.66 G

1.08 x 10-4 (cpm) + 6.25 1.05 x 10-4 (cpm) + 6.99 H

I 1.09 x 10-4 (cpm) + 6.88 1.09 x 10-4 (cpm) + 5.89 J

K 1.07'x 10-4 (cpm) + 6.73 L

1.05 x 10-4 (cpm) + 7.84 i

M 1.08 x 10-4 (cpm) + 6.81 1.07 x 10-4 (cpm) + 7.74 N

0 1.09 x 10-4 (cpm) + 7.32 P

1.09 x 10-4 (cpm) + 7.36

  • Calibration was done using linear regression on the readings obtained with the survey meter and the PIC for backgraund

(-10pR/hr), Source A (- 85~uR/hr) and' Source B (-100 pR/hr) at each site.

15

III-B.

Thermoluminiscent Dosimeter and Gamma Survey Data (continued)

Table 9 Comparison of TLD and PIC Data (pR/hr)

(11c)

Correction Factors

Date Site 56 mg/cm2 1 g/cm2 56 mg/cm2 1 g/cm2 09/23/79-H 7.510.8 6.010.3 6.9 0.92 1.15 02/03/80 09/23/79-E 6.9!0.5 6.0 0.3 7.4 1.07 1.23 02/03/80

  • PIC Data divided by TLD data.

Table 10 Comparisons of Data Obtained (instantaneous readings) from PICS and NaI (TI) y Survey pR/hr Date Site H Site E y

PIC y

PIC 09/23/79 7'. 4 6.5 7.3 7.2 10/06/79 7.5 7.0 7.4 6.8 10/20/79 7.4

. 6.8 7.4 7.2 11/17/79 7.4 7.3 7.4 7.5 12/01/79 7.5 7.1 7.4 6.9 12/15/79 7.4 7.9 7.4 6.7 12/29/80 7.5 6.9 7.4 7.0 01/12/80 7.4 7.0 7.3 6.0 03/08/80 7.4 6.7 7.4 7.1-04/19/80 7.3 6.7 7.3 7.9 G5/31/80 7.3 6.5 7.4 7.0 06/28/30 7.4 9.0 7.3 07/12/80 7.3 6.8 7.3 07/25/80 7.4 7.2 7.4 Average 7.410.1 7.110.7 7.410.1 7 0 0.5

  • Unit out of service.

i 16

Table 11 O

Y Average Background Dose from y-Survey Y

Wind uR/hr j

Date Direction A

B C

D E

F G

H I

J K

L M

N O

P o

06/16/79 N

6.8 6.8 6.6 7.6 7.3 7.0 6.6 NA 7.2 6.3 7.1 8.2 7.2 8.1 7.8 7.7 0

06/23/79 S

6.2 7.1 8.2 7.2 8.1 7.7 7.8 E'

06/29/79 N

6.8 6.7 6.5 7.6 7.4 7.0 6.6 NA 7.2 E'

07/06/79 S

6.3 7.1 8.1 7.1 8.1 7.7 7.8 2

07/14/79 No wind 6.9 6.9 1 5. 46 7.7 7.6 7.1 6.7 7.4 7.3 3

07/21/79 NE 6.3 7.1 8.1 7.1 8.1 7.7 7.8 c

' 07/28/79 N

6.8 6.8 6.6 7.7 7.4 7.0 6.6 7.4 7.3 S

09/22/79 S

7.1 8.2 7.1 8.1 7.8 7.8 E'

09/23/79 E

6.9 6.8 6.6 7.7 7.3 7.0 6.7 7.4 7.3 g

09/29/79 No wind 6.4 7.2 8.3 7.3 8.2 7.9 8.0 N

10/06/79, NW 6.8 6.7 6.6 7.7 7.4 7.1 6.7 7.5 7.3 m

10/13/79 NE 6.2 7.1 8.2 7.2 8.1 7.8 7.9 E.

10/20/79 SE 7.0 '6.8 6.7 7.7 7.4 7.0 6.6 7.4 7.4 a

10/27/79 NE 6.3 7.1 8.2 7.2 8.1 7.8 7.9 11/04/79 S

7.0 6.9 6.8 7.9 7.6 7.2 6.8 7.6 7.5 11/10/79 E

6.3 7.1 8.1 7.1 8.1 7.8 7.9 m

11/17/79 SW 6.9 6.9 6.8 7.7 7.4 7.1 6.6 7.4 7.3 5

-11/23/79 NE 6.3 7.1 8.2 7.2 8.1 7.7 7.7 12/01/79-NW 6.8 6.8

-12/08/79 NE

'6.6 7.7 7.4 7.1 6.7 7.5 7.4 6.3 7.1 8.2 7.2 8.1 7.6 7.8 E'

12/15/79 S

6.8 6.8 6.6 7.7 7.4 7.1 6.7 7.4 7.3 E

'12/22/79. No wind 6.3 7.1 8.2 7.2 8.1 7.9 7.9

-s 12/29/79 No wind-7.0 7.0 6.7 7.7 7.4 7.0 6.7 7.5 7.4 o

01/05/80 No wind 6.3 7.1 8.2 7.2 8.1 7.7 7.8 5

01/12/80 S

' 6. 9, 6.8 6.7 7.7 7.3 7.0 6.7 7.4 7.3 E'

01/19/80' NW 6.3 7.1 8.2 7.2 8.2 7.8 7.8 5

01/26/80 N

'6.7 6.8 6.5 7.6 7.3 7.0 6.7 7.3 7.3 Eb 02/03/80 No wind 6.4 7.2 8.3 7.2 8.2 7.8 7.8 02/09/80 N

6.8 6.7 6.5

-7. 6 7.3 7.0 6.6 7.4 7.3 02/16/80 W

6.2 7.1 8.2 7.1 8.1 7.6 7.7 02/23/80-N 6.8 6.8. 6.6 7.7 7.3 7.1 6.7 7.4 7.3 03/02/80 NE 6.2 7.1 8.2 7.2 8.1 7.7 7.7

111-B.

Thermoluminiscent Dosimeter and Gamma Survey Data (continued)

Table 12 Radiation Exposure from Airborne Effluent Sept. 23, 79 - Feb. 3, 80 Feb. 3, 80 - June 11, 80 Location Net mR Net mR A

0.6 0.4 B

0.9 0.7 C

0.3 0.1 D

0.6 0.3 E

0.3

-0.1 F

0.6 0.3 G

0.3

-0.3 H

0.3 0.3 I

-0.1 0.2 J

0.6 not available K

0.3 0.1 L

0.6 0.6 M

0.9 0.8 N

0.6 0.5 0

1.5 1.4 P

1.2 1.4 Average 0.6 0.4(1o) 0.4!0.5 (lo)

Note: Net UR/hr is TLD average exposure rate (in g/cm 2 shield) without.

background. This value was calculated by subtracting from the values in Table 7, 5.7.pR/hr and 5.0 pR/hr during the September 23, 1979 - February 3, 1980 and February 3, 1980 -

June 11, 1980. These valueu are the PIC average background exposure' rates of 6.9 and 6.1 UR/hr, respectively, divided by l

1.2 (see Table 9) to convert to TLD values.

18

l

III, 1parmoluminiscent Dosimeter and Gamma Survey Data (continuca)

The measured exposure rates due to airborne effluents in the period a

i September 23, 1979 - February 3, 1980, average 0.6!0.4 mR (la) and in the period February 3,1980 - June 11,1980, average 0.4!0.5 mR (la).

The average value is consistent with the estimated cumulative gamma dose values of 0 - 0.2 mR at these locations. This yields a 30 minimum detectable level of about 1.5 mR per quarter. The uncertainty of the total measurement averages about 0.4 mR per quarter (Table 7) and of the background value subtracted from it, which appears to have a t

similar average standard deviation. The minimum detectable annual expogurebythisprocedureforfourquarterlyTLDmeasurementsis i

3(4).5 = 6mR/ year.

]

IV.

Conclusion LiF TLDs could accurately measure the station-contributed dose when the current period background was subtracted; the current period background being determined by a survey meter standardized against a PIC-measured exposure rate.

The procedure utilizing two PICS and sets of 16 TLDs yields exposure results that permit measurements as low as 6 mR per year, based on a standard deviation of 0.5 pR/hr when the exposure rate from airborne i

effluent is near 0.1 uR/hr. Determination of differences in the back-ground values at the 14 non-PIC locations should be improved by perform-ing more precise measurements with survey meters and also making PIC measurements at each location, possibly twice each year.

The results obtained from the Dresden EDPS program (1979) suggested that the off-axis finite plume model most accurately reflected the i

measured exposure at a near-the-boundary site. This model provides realistic and useful estimates of the measured exposures so long as appropriate corrections are made for periods of extremely unstable atmospheric conditions with the monitor bearing close to the down-wind wind direction.

The releases from Quad Cities Station dr 'cg the period of this study were very small and it is reflected in Coe measured data.

l l

l l

l 19 I

NO MNib OUAD EDPS - 10 DINE-131 in MILK 1.

Introductioa The thyroid dose rate of 15 mrem /yr per reactor given in POCFR50 Appendix I as the numerical guide for design objectives and limiting conditions for operation to meet the criterion "as low as is reasonably achievable" for radioactive effluents indicates that airborne I-131 may be among the radionuclides that cause the highest organ dose near nuclear power stations.

The critical pathway is usually airborne effluent-to-air-to-pasture grass-to-cows' milk-to-infants.

Regulatory Guide 1.109 (Revision 1, October 1977) gives a dose / ingestion factor of 0.0139 mrem to the infant thyroid per pCi ingested.

At the consumption rate of 330 liters /yr given in the same guide, an average concentration of 1 pCi/ liter milk leads to an annual dose to the infants thyroid of 4.6 mrem due to I-131.

Hence to reach the 15 mrem /yr per reactor desigi objective, an annual average concentration of 3 pC1/1 is required.

Because of the critical role played by I-131 in the siting and oper-ation of nuclear reactors this study was designed to evaluate the accuracy of the calculational model used to demonstrate compliance with the design of objectives.

In this study, the levels of I-131 in milk from two farms near Dresden Station were measured and compared to concentrations predicted by the mathematical model of NRC Regulatory Guide 1.109 (Revision 1, October 1977).

However, only the direct transfer of I-131 onto plant foliage was considered after an evaluation of the model showed that the root uptake and stored feed pathways contributed little to the iodine intake of the dairy animals relative to that from foliage.

It was further assumed that only one-half of the iodine was in the elemental form, the forn most likely to deposit onto vegetation.

l II.

Study Plan A.

Calculation Model As previously e:ated, the environmental transfer model of Regula-tory Guides 1.109 and 1.111 was used weekly to predict I-131 concentra-tions in milk.

Station I-131 effluents measured daily and site meteor-ology measured hourly were used in the predictions.

The principal parameters of the rodel are given in Table 13.

B.

Sampling Program - Description Samples of about 1.5 liters of milk were obtained from the morning and evening milkings of two farms, one located five miles N the other 20 l

t l

1

II-B.

Sampling Program - Description (continued) 2.5 miles SW, until the weekly collection was made.

The milk collected on each day was kept frozen and sent to the laboratory at the end of each week for stable iodide and 1-131 analyses.

C.

Analytical Procedure Methodology Stable iodide concentrations of the samples were measured using a specific ion electrode.

Concentrations of stable iodide in milk have been shown in this and other studies to be quite variable and often quite high, making knowledge of the total iodide present, not only carrier, imporrant to chemical yield determinations.

Radioiodine-131 is isolated from milk with stable iodine carrier (corrective also for the presence of stable iodide content) and ani?n exchange resit Cie iodine is eluted from the resin with Na0Cl which also oxidir e it to the iodate.

The iodate is reduced to iodine with hydroxylamine in -3N nitric acid solution.

The iodine is extracted into carbon tetrachloride, then reduced to iodide with sodium bisul-fite, extracted into water and precipitated as AgI from an acidified solution, filtered and washed with NH 0H to remove any AgC1.

Sample 4

is dried, weighed to determine the gravimetric yield of iodide and counted in low level beta counters for about 1000 minutes and the measured I-131 concentrations were decay corrected to the mid-time of sample collection.

Ill. Results Analytical results are summarized in Table 14 for Hanson Farm (5 miles N) and Table 15 for Turner Farm (2.5 miles SN).

^

Tables 14 and 15 summarize the result from each week.

IV.

Conclusion i

Since the Iodine-131 releases from the Quad Cities Station were very small, the cows were permitted to graze only-for an unknown limited periods by the farmers and the measured I-131 levels in milk were near or below the detection limit of 0.01 pC1/1, a fruitful comparison of measured vs. calculated I-131 concentrations in milk is not possible.

Considering these limitations the findings of the Dresden ED?S (1979) program are the only information gathered by EDPC. At Dresden the comparisons of measured and computed I-131 concentrations indicate agreement by better than a factor of two over a period of-half a year.

N 21

i i

TABLE 13 l

Principal Constants Used in I-131 Milk Pathway Model i

Pa rane t.c r Description Value F

Fraction of daily intake which appears in milk 6x10- d/1 m

Qg Amount of seed (grass + stored seed) consumed per day 50 kg/d A

Radiological decay constant of I-131 3.61x10- hr-1 f

Fraction of time animals are in pasture 1.0 p

i Fraction of daily seed that is pasture grass 1/2 s

A Effective decay constant = Au + A 5.67x10- hr-1 n

A Environmental weathering removal constant 2.1x10- hr-1 y

Fraction of released activity retained on pasture grass 0.5 i-te Period of pasture grass exposure 720 hr Yv Agricultural productivity percent area 0.7 kg/m2

'r Release period 720 hr E

Q,,

, Release rate a C1/wk Dr Relative Deposition AA m-I R

Itange : Station to dairy farm N 8000m SW 4000m a as reported by the station.

AA Fron USNRC Regulatory Guide 1.113 (Revision, July 1977)

't 22

.--u

'l TABLE 14 Q-17 Hanson Farm 5 miles N Collection I-127 Grav.

Net cpm I-131 Date e-At Vol(1) mg/l Yield i la pC1/1 lo 06/14/79 0.48 21.0 1.00 0.61 0.09!0.04 0.02 0.01 06/21/79 0.55 18.0 1.02' O.52 0.09!0.05 0.02!0.01 i

06/28/79 0.33 17.5 0.32 0.43 0.00 0.08 0.00 0.03 07/05/79 0.35 19.5 0.78 0.45 0.12!0.05 0.05 0.02 07/11/79 0.36 16.1 0.67 0.43 0.03t0.07 0.02 0.04' i*

07/18/79 0.46 18.0 0.91 0.43

-0.0910.05

-0.03!0.02 i

07/26/79 0.50-12.0

1. F'J 0.37 0.00 0.047 0.00!0.03 08/02/79 Sample destroyed during shipment.

08/09/79 0.30 16.0 0.69 0.41 0.04!0.05 0.0310.03 08/16/79 0.55 16.6 0.72 0.49 0.04!0.09 0.01 0.02 08/23/79 0.50 16.8 1.00 0.35

-0.08 0.05

-0.03 0.02 08/30/79 0.42 18.9 0.84 0.19 0.20!0.05 0.08 0.02 09/06/79 0.50 13.0 1.10 0.32

-0.02 0.05

-0.01 0.03

[

09/13/79 0.55 15.3 0.52 0.63 0.12!0.07 0.03!0.02 09/20/79 0.46 21.0 2.36 0.47 0.2810.08 0.0910.03 09/27/79 0.39 19.6 1.47 0.58 0.00 0.07 0.00!0.02 10/04/79 0.46 20.3 1.54 0.34 0.30 0.07 0.12!0.03 10/11/79 0.48 18.9 1.59 0.35 0.0710.07 0.03 0.03 10/18/79 0.28

-16.8 1.87 0.32

-0.10 0.07

-0.09 0.06 10/?5/79 O.55 18.2 1.41 0.48

-0.12 0.07'

.-0.03 0.02 11/01/79 0.50 14.7 1.45 0.51 0.06 0.07 0.02 0.02-11/08/79 0.46 14.7 1.38 0~55

-0.01 0.07 0.0010.01 l

11/15/79 0.36 14.0 1.07 0.73 0.P.910.07 0.04 0.03 11/22/79 0.36-17.5 0.93 04 63 0.1710.08 0.06 0.03 11/29/79 0.50 13.0 1.34 0.73 0.04!0.07 0.01 0.02 12/06/79 0.50' 14.5 1.44 0.58 0.02 0.07 0.01!0.02 12/13/79 0.50 18.0 0.24 0.65

0. 01.+0. 07 -

0.0010.02 12/20/79 0.16 12.0 0.69 0.96 0.03 0.07 0.02 0.07 l

12/27/79 0.33 15.5

.0.73 0.59

-0.02!0.07

-0.01i0.03 01/02/80 0.46 16.5 0.87.

0.65 0.10!0.07 0.03 0.02 i

01/10/80~

0.23 15.0 0.65-0.62

-0.1520.06.

-0.09 0.04 i

01/17/80 0.36 16.0 0.72 0.55

-0.07 0.07

-0.03 0.03 j

01/24/80 0.33 15.0 0.60 0.59

-0.06!0.07.

-0.02 0.02

)

02/01/80 0.57 16.0 0.54 0.76~

- -0.13 0.06-

-0.03 0.01

]

02/07/80 0.34 15.5 0.51' O.64 0.06!0.08

.0.02 0.03 02/13/80 0.50 19.0 0.60 0.57

-0.05!0.07

-0.01 0.02 J

4 4

23

,n-

~.wg

~-

.m----,,

---n~

w

4 TABLE 15 Q-34 Turner Farm 2.5 miles SW Collection 1-127 Grav.

Net cpm I-131 Date e-At Vol(1) mg/l Yield t la pCi/1 1 lo 06/20/79 0.31 15.0 0.86 0.65 0.0010.05 0.00!0.02 06/26/79 0.26 11.8 1.60 0.42 0.07!0.07 0.0710.07 07/02/79 0.27 15.9 0.56 0.33 0.0810.06 0.0610.05 07/10/79 0.31 16.8 0.99 0.45 0.26 0.07 0.1410.02 07/17/79 0.23 14.4 0.61 0.53

-0.00!0.05 0.0010.03 07/24/79 0.28 14.4 0.93 0.56 0.0210.07 0.01 0.04 07/31/79 0.42 15.0 0.71 0.38 0.0710.05 0.04!0.03 08/07/79 0.28 16.5 0.39 0.16 0.2510.07 0.40 0.11 08/14/79 0.28 16.8 0.41 0.16 0.00!0.07 0.00 0.11 08/21/79 0.28 19.2 0.78 0.47 0.4210.05 0.21!0.02 08/29/79 0.30 16.2 0.45 0.47 0.0410.07 0.02!0.04 09/04/79 0.30 14.0 0.41 0.25 0.09i0.06 0.10 0.07 09/12/79 0.23 21.0 0.73 0.52 0.4110.07 0.1310.02 09/20/79 0.44 14.6 0.91 0.56 0.3410.08 0.1420.03 1

09/26/79 0.46 21.0 0.48 0.51 0.1610.07 0.04!0.02 10/03/79 0.42 16.2 1.31 0.43 0.1710.07 0.07!0.03 10/10/79 0.46 17.5 1.90 0.34 0.1510.07 0.07 0.03 10/17/79 0.46 16.8 2.24 0.45 0.12!0.07 0.0510.03 10/24/79 0.46 21.0 1.40 0.38

-0.0510.07

-0.0210.02 11/01/79 0.48 18.4 1.32 0.38 0.0410.07 0.0210.02 11/08/79 0.55 21.0 0.82 0.61 0.0210.07 0.00 0.01 11/15/79 0.33 16.9 0.33 0.72 0.03!0.07 0.01 0.02 11/22/79 0.46 20.0 0.81 0.50

-0.0610.07

-0.0110.01 11/29/79 0.50 20.0 0.74 0.75

-0.12 0.07

-0.0210.01.

12/05/79 0.50 20.0 0.84 0.65 O.0410.07 0.01!0.01 12/14/79 0.37 21.5 0.93 0.99 0.0410.07 0.0110.02 12/20/79 0.26 16.4 0.72 0.84 0.1010.07

'0.0410.03 1

12/27/79 0.30 24.0 0.43 0.62 0.07 0.07 0.02!0.02 01/02/80 0.37 15.9 1.06 0.68 0.09 0.07

.0.0310.02 01/10/80 0.25 15.5 0.69 0.66 0.0110.06 0.0120.03 01/17/80 0.46 17.0 0.71 0.51 0.03 0.07 0.0110.02 01/24/80 0.55 10.0 0.54 0.67

-0.0510.07

-0.0210.02 1

02/01/80 0.34 15.0 0.67 0.51

-0.11 0.07

-0.05t0.03 02/07/80 Sample lost in processing 02/13/80 0.39 18.5 0.50 0.52

.-0.0720.07

-0.0260.02 5

24

Section III OUAD EDPS - AOUATIC PATINAY STU co o

r i

(1979-1980) 3 C' *>

C#

I.

Introduction The aquatic pathway study at Quad Station consists of measurements of radioactivity in edible fish tissue. The major nuclides examined were I-l j l, Cs-134, Cs-13 7, and P-32.

The area where the fish were collected is not a commercial fishing area.

Some sport fishermen frequent the area during the seasons. Nearly fifty species of fish have been identified in the bay, although many are not eaten by man.

In this report, the fish collected have been classified according to feeding habits and human consumption, both being important in consideration of the food chain.

II.

Study Plan Seven (7) species of fish were collected and are listed in Table 16 which indicates particulars about those species.

Samples were frozen immediately after collection, and returned to the laboratory on dry ice.

1%r analysis, the fish were thawed and weighed, and those of sufficient size were dissected to separate the edible portion.

Small fish were analyzed whole. Measured concentrations were then to be compared to calcu-lated concentrations using the model of Regulatory Guide 1.109.

III. Results Table 17 summarizes the data on the radionuclide concentrations in fish collected during the period 06/79 - 08/79.

Small amounts of Cs-137 (0.005 - 0.028 pCi/g wet) were detected in ten fish samples that were attributable to atmospheric fallout. No Cs-134, I-131 or P-32 was detected in the fish samples. The absence of plant attributable activity in the fish prevented accurate comparison with the calculated concentrations.

IV.

Conclusion During this study period the releases from Quad Cities Station were very small and the measured concentration of plant released radioactivity in fish were below the detection limits. Based on the results from Dresden EDPS program (1979) the impact of station discharges to the aquatic environ-l ment as represented by fish are too small to be detected even with the sensi tive techniques herein. The model indicates that the dose via the i

aquatic pathway is very small, very much less than 1 mrem.

l 25 I

t

t t

Table 16 Fish Collected at Quad Station Fish Name Food '

Human

, Habitat **

Consumption Carp Bottom feeder - opportunist

  • Resident - Most abundant Yes Sunfish Opportunist
  • Resident - Abundant Yes Crapple Fish, animal foods Resident - Abundant Yes c

Large Mouth Bass Fish, animal foods Resident - Not very abundant Yes Gizzard Shad Plankton Resident - Abundant No g'

Blue Gill Opportunist

  • Resident - Abundant Yes Carp Bottom feeder Both - abundant Yes Consumes any food available to him.
    • Migrant - fish that enters the area during certain seasons of the year.

Resident - fish continuously present in the area.

l l

Table 17 Camma Emitters (I-131, Cs-134, and Cs-137) and P-32 in Fish Collection pCi/g wet Date Location Species I-131 Cs-134 Cs-137 P-32 06/28/79 Upstream Bluegill

<0.08

<0.01

<0.01

<2.0 06/07/79 Upstream-5 Carp

<0.10

<0.01 0.02io.010

<2.0 06/14/79 Downstream-8 Carp

<0.05

<0.01 0.0110.010

<2.0 06/29/79 Below Station Crappie

<0.02

<0.01

<0.01

<2.0 07/31/79 Upstream Carp

<0.04

<0.005 0.00810.002

<0.9 07/24/79 Downstream Crappie

<0.20

<0.005 0.00710.002

<4.0 NA Downstream Carp

<0.30

<0.005 0.01510.001

<0.3 07/24/79 Upstream Bluegill

<0.03

<0.003

<0.003

<2.0 07/24/79 Upstream Crappie

<0.04

<0.003 0.00610.001

<1.0 08/31/79 Upstream-1 Large Mouth Bass

<0.80

<0.040

<0.040 (0.2 08/29/79 Upstream-34 Sunfish

<0.60

<0.010 0.02810.003

<1.0 08/31/79 Downstream-110 Cizzard Shad

<0.06

<0.004

<0.004

<0.05 08/14/79 Upstream-66 Gizzard Shad

<0.07

<0.005

<0.005

<1.0 03/14/79 Downstream-11 Crappie

<0.80

<0.005

<0.005

<2.0 08/08/79 Upstream-60 Gizzard Shad

<0.90

<0.005

.0.00510.001

<1.0 08/08/79 Upstream-2 Carp

<0.40

<0.006

<0.009

<0.3 08/09/79 Downstream-4 Carp

<0.30

<0.003 0.00710.001

<0.2 08/14/79 Upstream-1 Carp

<0.70

<0.005

-0.005!O.002

<0.3 27

Section IV QUAD CITIES EDPS - SOURCE TERM STUDY (1979-1980)

Due to scheduling difficulties this portion of the study was not conducted.

28

O e

ENVIRONMENTAL DOSE PATHWAY STUDY QUAn CITIES STATION

- APPENDIX -

ANALYTICAL PROCEDURES

Radiodina in Milk or Water 2-24 subjec t.:

page:

Radiochemical Determination of I-131 in Milk 1-16-75 date-Revised 10/15/79 or Water with Low Beta Counting approved: kg REACENTS 3 (416M), 4M HNO, 0.2M HNO3 70% llNO 3

36% llCL (%12M) 30% Nil 0ll

(%15M) 4 0.085 M KI (10 mgI/ml) 0.045 M AgNO3 5% Na0Cl (or Clorox) 2M liydroxylamine Hydrochloride Solution Carbon Tetrachloride 2.4 cm diameter Glass Fiber Filter Anion Exchange Resin, 20-50 mesh, chloride form (Dowex 2 x 8 or equivalent) 10% Sodium Bisulfite EQUIP!1ENT

'A glass tube (N2.5 cm. ID) is plugged with a small piece of aquarium fiber floss. A suspension of 430 g. of Dowex 1x8 (20-50 mesh) anion exchange resin in the chloride form is poured into the tube to make a resin column about 10 cm. in height. The column is then connected to a 4 liter plastic reservoir by latex tubing. The flow rate to be adjusted using a screw clamp.

Ilot Plate 15 m1, 125 ml Millipore Filter Apparatus 250 m1, 500 ml Beakers Weinbing llalance, 0.000lg 1,ow Background Beta Counter I'unnel Hack 10 m1, 25 ml Graduated Cylinders 500 ml Separatory Funnel 125 ml Separatory Funnel 30

2-25 subject: Environmentcl Monitoring p;ge:

[] title: Radiochemical Determination of I-131 in Milk date: 04/27/78 or Water with Low Beta Counting Revised:

10/15/79 approved: ((s qpf 90 e

METHODOLOGY Radioiodine-131 is isolated from milk with stable iodine carrier and anion ex-change resin. The iodine is eluted from the resin with Na0Cl which also oxidizes it to the iodate.

The iodate is reduced to iodine with hydroxylamine in %3N nitric acid solution. The iodine is extracted into carbon tetrachloride, reduced to iodide with sodium bisulfite, extracted into water and precipitated as AgI from an acidified solution, filtered and washed with NH OH to remove any AgCl. Sample

{s dried, weighed to determine gravimetric yield or iodide and beta counted.

31 I content is determined from chemical recovery of iodine, decay, analysis volume 131 /1.

and instrument efficiency.

Recovery is 70% and MDA is 0.1 pCi I

PROCEDURE 1.

Pour a known volumn (%201) of milk into the piastic reservoir (Note 1).

Adjust the pil of the milk to approximately 8 using 6N NaOH (pH paper is ok).

Add a known amount of iodide carrier ( N20 mg. as AgI).

Stir thoroughly using 2.

a glass rod.

3.

Open the screw clamp and adjust the flow rate to be N100 ml/ min.

4.

Transfer the *ffluent milk to its original container.

5.

Transfer the resin from the column to a 250 mi beaker. Wash three times (or more if needed) with

%50 ml of hot DI water to remove adhering butterfat.

6.

Add 50 ml of 5% Na0C1 (chlorox) and stir for N20 minutes. Decant as much of the liquid as possible into a clean 600 ml beaker, or filter through a What--

man No. 541 filter paper to separate the resin from the liquid if more convenient.

7.

Repeat atep 6 with 50 ml portion of 5% Na0Cl (chlorox) combining all the liquids in the beaker.

Filter the last extraction to remove all the solution, wash the resin with %20 ml of chlorox, and filter.

by adding %35 ml concentrated nitric 8.

Make the solution approximately 3M in HNO3 acid.

Heat to boil and stir in a fume hood. Cool and transfer the solution into a 500 mi separatory funnel.

9.

Add 15 ml of carbon tetrachloride and shake the contents (use the fume hood).

Add 45 m1 freshly prepared 2M hydroxylamine solution. Mix, stopper to avoid 10.

loss of 12, shake vigorously, and allow a few minutes for reaction to go to completion.

If the solution does not have a definite amber color, add more hydroxylamine.

11.

Allow the liquid phases to separate, and drain the organic layer into a clean 125 mi separatory funnel containing 25 ml of DI water. Note: Organic layer will turn lavender if the above steps were performed correctly.

31

Radiodine in Milk or Water 2-26 subject:

page:

Radiochemical Determination of I-131 in

[] title: Milk or Water with Low Beta Countine date: 01/16/75 g

g,,g Revised 10/15/79 approved: M_gp PROCEDURES (Cant'd) 12.

Repeat the extractions with a second portion (15 ml) of carbon tetrachloride, until no I2 color is apparent in the organic layer. This should require no more than 2 extractions or until there is no additional color change of the organic layer. Combine all the organic fractions in the separatory funnel.

13.

Add a few drops of sodium bisulfite solution (100 grams / liter) and shake.

Both layers should now be colorless.

Discard the organic phase and work with the 25 ml of water.

14.

Transfer the water layer containing iodide to a clean 100 m1 beaker, lieat precipitation of AgI,2 (av id prolonged heating) which would interfere with to boling to expel S0 and add 5 ml of 4 N HNO.

3 15.

Add 4 ml of 0.045M AgNO3 slowly while stirring the hot solution.

Kt p warm until precipitate has coagulated to permit good filtering.

16.

Decant supernatant through a tared Whatman No. 42 filter paper.

17.

Add %2 ml of conc. Nii 0ll to the precipitate remaining in the beaker and 4

stir (use the fume hood).

18.

Filter. Wash with warm water, followed by 0.2N HNO and with 10 mi hot DI 3

water.

19.

Dry to constant weight (use the oven at 4100, for 420 minutes).

0 20.

Weigh precipitate and record weight.

21.

Transfer the filter paper to a SS planchet, and count with the Low Beta system. Counting time should ba adjusted to achieve sensiti-. ty specified by client.

(Sce ilASL-300, Section D-08)

Note 1 (a)

If the milk has fat globules, filter the milk through a small piece of fiber floss using a large funnel.

(b)

If the milk is sour, then avoid using the column method and use a plastic bucket and stir using a stirring apparatus (batch method) as follows: A known volum (4-81) of milk is placed in a plastic bucket.

Adjust the pH to 8 and add a known amount of iodide carrier. A submersible pump is placed in the solution to mix the contents. Add

%30g of resin and the milk is stirred for %1 hour. The pump is then removed and the resin is allowed to settle. Decant the milk into its original container and transfer the resin to a beaker and start with step 5 of the procedure.

32

2-W subject:

Procedure for Determination or stahn Iodide page:

[] title:

date: 05/02/77 approved:

b9 REAGENTS Iodide Standard Stock Solution (e.g. 100 ppm)

SM NANO 3 (I nic Strength Adjustor)

EQUIPMENT 150 m1 beakers 1" magnetic stirring bars and stirrer thermometer 10 ml or 25 ml burette 2 ml pipet Ionalyzer Unit (with iodide and reference electrodes)

CllECKING ELECTRODE OPERATION (to be done before each use) 1.

Put 100 ml distilled water and 2 ml ISA into a 150 ml beaker.

Turn the function switch to the F position.

Place electrodes in the solution to a depth of about 3 cm (1 inch).

2.

Pipet 1 ml of 100 ppm standard into the solution.

Stir thoroughly.

Adjust the calibration control until the meter needle (red scale) points to 100 at the center of the scale.

3.

Add 10 ml of 100 ppm standard.

Stir thoroughly.

Adjust the temperature compensator until the meter needle points to 1000 at the extreme right of the red scale.

Turn the clear slope indicator dial until the white arrow on the temperature compensator points to the temperature of the solu-tion-Read the percent electrode slope on the lower scale of the dial.

Correct electrode operation as indicated by a percent slope between 97 and-100.

If this_is not obtained, see your supervisor.

DIRECT MEASUREMENT PROCEDURE 1.

Prepare standards in the range of 1 ppm to 100 ppm from the stock solution.

2.

Add 2 ml of ISA to every 100 ml of the standard solutions.

Stir thoroughly.

3.

Place electrodes in the 1 ppm standard.

Stir thoroughly. Adjust the meter needle to 100 on the red scale (center scale).

4.

Rinse electrodes, blot dry and place in the 10 ppm standard.

Stir thoroughly.

Turn the temperature compensator knob until the meter needle reads 1000 (full scale) on the red scale.

D**]D * ]D [lT f M 33 o o Ju o Juu l h. C

subject:

Procedure for Determination of Stable Todide 2-31 page:

[3 title:

date:

05/02/77 approved:

1 DIRECT MEASUREMENT PROCEDURE cont'd 5.

Transfer 100 ml of sample to a 150 ml beaker. Add 2 ml ISA and stir thoroughly (larger volume of sample may be used if required and add 2 ml ISA per 100 ml of sample).

6.

Rinse electrodes, blot dry and place in sample.

Stir thoroughly.

Read the meter value on red scale and' determine the sample concentration in ppm or mg/l from the calibration curve.

Or multiply the meter reading on the red scale by 0.01 to determine the sample concentration in ppm or mg/1.

OFF-SCALE READINGS IN SAMPLE If the needle goes off scale right, rinse electrodes, blot dry and place in the 10 ppm standard.

Adjust the calibration control until the needle points to 10

' center scale) on the red scale.

Rinse the electrodes, blot dry and

._gi..

_ in sample.

Multiply the meter reading on the red scale by 0.1 to determine the sample concentration in ppm or mg/1.

If the needle goes off scale left, rinse the electrodes, blot dry and place them in the 1 ppm standard. Adjust the calibration control until the needle points to 1000 (full scale right) on the red scale.

Rinse the electrodes, blot dry and replace in sample.

The meter reading on the red scale multiplied by 10-3 is

' equal to sample concentration in ppm or mg/1.

KNOWN ADDITION METiiOD (sample concentration must be known to within a factor of three) 1.

Prepare a standard solution about 100 times as concentrated as the sample concentration.

2.

To measure an unknown sample, place electrodes in 100 ml of sample and add 2 ml ISA.

3.

Turn the function switch to X, set the slope indicator dial to the percent slope determined in the daily checkout, and turn the temperature compensator knob to the sample temperature.

Set the needle to = on the green scale by turning the calibration control.

4.

Pipet 1 ml of 100 ppm standard solution into 100 m1 sample.

Stir thoroughly.

Record the reading 'R' from the green scale.

5.

To determine the original sample concentration, use the following equation:

Co =

R Cs where:

Co = sample concentration 100 R = reading from green scale Cs = concentration of added standard 34

The following procedures were used in the analyses of fish:

I.

Iodine-131, Cesium-134, and Cs-137 Edible portions of fish were separated and digested carefully with 2.5 M NaOH contr.ining -10 mg I Carrier on a hotplate to dry-0 ness.

The sample was then ashed in a muffle furnace at 600 c. and the ash was transferred to a suitable container for gamma isotopic analyses using a Ge(Li) detector.

II.

Phosphorus-32 (a) Weigh out -200g of fish fillet.

Record the wet weight.

(b) Dry the sample at -110 c. and record the dry weight.

(c)

Place the dry sample in a crucible and ash at -700 c.,

till it is completely ashed.

(d)

Pulverize the ash and record the ash weight. Transfer the ash to a 250 ml beaker.

Add -50 ml of 8N HNO3 to the crucible and transfer to the beaker.

Heat to boiling with stirring for -30 minutes and allow it to cool.

(e)

Filter though a 5.5 cm glass filter and rinse the filter with DI water.

(f)

Refilter the filtrate through a 47 mm Millipore filter.

(g) Add 6N KOH until a precipitate is formed. Add 8N HNO3 drop-wise until precipitate is dissolved. Adjust the pH to 2 with a pH paper.

l (h) Transfer to a 100 ml volumetric flask and dilute to the mark with DI water.

(i) Determine the stable' phosphorus' content by using the procedure on page'8-5.

~

(j) Proceed to separation of phosphorus by using the procedure on page 8-7.

t 35

l 8

Colorimetric Determination of Stable Phoephorus page: _ -5 g

10/20/78 Stable Phosphorus Determination date:

0 title:

approved:

REACESTS:

StandardPhosphorusholutions:

1.

(a) Standard 1:

(5g P/1) 21.32g (Nii ) HPO, dried at -100 C is dissolved 4

4 in 1 liter of DI water in a volumetric flask.

(b) Stanaard 2:

(50 ug /ml) 10 ml of Std. #1 is diluted to 1 liter with DI water in a volumetric flask.

2.

Vanadate-Molybdate Solutions:

(a) Solution A:

Dissolve 25g of ammonium molybdate tetrahydrate in 400ml of DI water.

(b) Solution B:

Dissolve 1.25g ammonium meta vanadate in 300 ml of DI water.

Heat to boil, cool, and add 300ml concentrated hcl.

'(c) :4ix solutions A and B to give one liter of Vanadate-Molybdate reagent.

(This needs to be made fresh each month.)

glUIP:W.::r 1.

Chemtrix 20 Colorimeter 2.

Cuvettes for Colorimeter PROCEDURE 1.

For each sampic take 70 ml of DI water in a 30 dram plastic vial.

2.

Knoten aliquots V (eg.

I mi from phosphate solutions prepared from fish 3

and 4 m1 from solutions prepared from urine samples) is transferred to the plastic vial.

3.

A series of standard phosphate solutions (blank, 5, 10, 15, 20, 25, 30, and M or, P/ml) are prepared as follows.

Measure in separate plastic vials 70, 60, 50, 40, 30, 20, 10, and 0 ml of DI water and add 0, 10, 20, 30, 40, 50,- 60, and 70 ml of phosphorus Std. #2 (50 ug/ml) respectively.

Add 20 ml of Vanadate-Molybdate reagent to each of the vials and dilute to 100 m1, or a known volume.

This can be done by volume or weight.

(V.)

2 5.

Allow the solutions to stand for N10 minutes before reading their absorbances, mon A W Q'M @

f N. b.

^

3 36

8-6 subject: Colorimetric Determination of Stable Phorphorut p;gy

[] title: Stable Phosphorus Determination date: 10/20/78 approved:

6.

Set the wavelengths dial 6f the colorimeter to 420 mu and ttni the power switch on.

Allow the instrument to stay on for %30 minutes uefore use.

7.

Place the blank cuvette in the holder and adjust the reading to 100%

transmission (zero absorbancy) with the zero adjust dial.

8.

Rinse the cuvette with the solution to be read and fill to the mark. Wipe the outside of the tube with a tissue paper.

Place the cuvette in the holder with the etch mark facing the operator.

9.

Unknowns and standards are read on the linear scale (% transmission).

Zero is reset between readings with the blank tube.

The % transmission readings of the unknowns should fall within the range of the standard values.

If the samples read higher or lower than the standards, their approximate concentration can be estimated.

Based on this estimation, the sample or the standard can be diluted appropriately.

10.

Absorbance (A) of the solution is calculated from the % transmission (%T) readings using the equation:

A=2-log (%T) 11.

Concentration of phosphorus (ug P/ml) is determined from the calibration curve.

The concentration of phosphorus P in the solution made in Step 4 is thus c

determined.

12.

The concentration of phosphorus (mg/ml) in the original solution is calculated from the equation:

P xV2 c

Pi mg/ml =

(Or Px in general) 1000 x Vg I

where Vi = m1 sample aliquot used in Step 2 V2 = total volume from Step 4 Pc = colorimetric value of phosphorus in ug/ml Pi = initial or original concentration of the sample.

(to determine V2 by weight: specific gravity of colorimetric solution (Step 4) is 1.016.)

G

. m M e na h E, 7

I l

l 37

SubjeCL: Radiophosphorus in Fish 8-7 page:

[] title: Radiochemical Separation of P-32 in Fish date: 10/20/78 approved:

RFACE:'TS :

1.

Cobalt Carrier:

1.010g CoC1 6H O in 50 ml of DI water (Smg Co +/ml).

2 2

2 2.3550g Zr(NO )4 5H 0 in 50 ml of DI water. (10 mg Zr+4/mt.)

2.

Zirconium Carrier:

3 2

3.

Silver Carrier:

1.575g Ag NO3 in 50 ml of DI water (20 mg Ag+/ml).

Store in dark or brown bottle.

4.

Manganese Carrier:

0.525g MnC03 in 50 ml of DI water containing 6N hcl just sufficient to dissolve any precipitate upon heating.

(5 mg Mn +/ml) 2 5.

Magnesia Mixture:

Dissolve 200 g Nil Cl and 230 g MgCl 6H O in DI water and 4

2 2

dilute to 1 liter.

PROCEDURE:

1. Transfer an aliquot (V, ml)) of the solution to be tested into a 250 ml beaker (solution from Step 8 of sampic preparation for fish on page 8r4 nnd step'4 from urine samples on page

).

The size of the aliquot is calculated so that V = 33.8 Pi where P is the amount of phosphorus in mg/ml determined f rom colorimetric i

determination on page 8-5 2.

Record the aliquot volume used.

Dilute to 50 ml with DI water.

3.

Add 1 ml of 8N llNO3 and 0.5 ml each of Cobalt, Zirconium, Silver, and Mauganese carricts.

4.

Add two drops of 30% 110 2 2(and slowly add 6N KOH until the hydroxides have compictely precipitated pH %9.0).

Ilen t to coagulate the precipitate and filter through two #41 filter papers in a buchner funnel.

Refilter through a #42 filter paper.

5.

Transfer the filtrate to a beaker and add two drops of 110 and tw drops

IIcat to coagulate.

Refilter through two #41 filter papers.

If the filtrato is turbid, refilter through f42 filter paper followed by using a 47 mm millipore membrane filter, if necessary.

6.

Acidify the clear filtrate with concentrated hcl and boil for %5 minutes to remove 11 0.

Cool in ice.

22 D"'" ]" J D

N

\\

D 38 o o Ju o

Ju 1 \\

n

subject: Radiophosphorus in Fish page:

[] title: Radiochemical Separation of P-32 in Fish date!_ 10/20/73-approved:

7.

Add 20 ml of magnesia mixture and neutralize to methpl red end point with conectrated NH 0H.

Allow it to stand for 2 minutes and add 43 ml more of 4

NH 0H.

4 8.

Filter through #42 filter paper in a Buchner runnel and */ ash the precipitate with IN NH 0H.

Discard the filtrate.

4 9.

Dissolve the precipitate in 6N hcl and collect the solution in a filtering flask.

10.

Transfer the solution to a 150 ml beaker.

11.

Repeat Steps 7-10 for second precipitation of Mg(Nil )PO.

4 4

12.

Repeat Step 7 for third precipitation of Mg(NH )PO.

4 4

13.

Tilter precipitate through 47 mm millipore filter and wash with IN Nil 011 4

folloued by alebhol.

14.

Slurry the precipitate on to a labelled SS planchet with small amount of DL uatcr.

15.

Dry the planchet at 2100 C. for %1. hour.

16.

Send the sample to the Counting room with a note to the Counting room personnel to return the sample to the lab after counting for colorimetric determination of the chemical yicid.

17.

'then the planchet is returned from the Counting room, dissolve the precipitate in 5 ml of IN hcl and transfer to a 100 ml volumetric flask with a few rinsings of DI water.

Dilute to 100 ml with DI water.

18.

Tahe a known aliquot Vg (5.0 ml) to determine the phosphorus concentration by colorimetry from page 8-5 19.

Calculate the phosphorus content in the precipitate as follows:

P mg/ml =

g y

where Px = amount of phosphorus in mg/ml calculated from Step'12 on page V g aliquot used in Step 18 on page a

20.

Calculate the chemical yictd by using the equation y =.P,g,.

Pi uhere Pg = final concentration of phosphorus in mg/ml after the chemical D"

3 39 oe o

m l'

subject: Radiophosphorus in Fish 8~9 page'.

0 title: Radiochemical Separation of P-32 in Fish date: 10/20/78,

G' approved:

separation; Pi = initial or original concentration of phosphorns in mg/ml.

4 4

i f

e T

1 e

e i

1 n--a, 40 J