LER 80-068/03L-0:on 800909,during Reactor Startup,Hpci Sys Turbine Control Valve 2E41-V9 Would Not Open W/Auxiliary Oil Pump Running.Caused by Cracked Electronic Governor Reverse Actuator Assembly Plug.Plug & Affected Components Replaced