Forwards QA Program Insp Rept 99900507/81-01 on 810119-23 & Notice of Nonconformance
ML19350D719
Person / Time
Issue date: 02/05/1981
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Randy Patterson
SARGENT & LUNDY, INC.
Shared Package
ML19350D711 List:
References
REF-QA-99900507 NUDOCS 8105180452
Download: ML19350D719 (2)


Text

'

[ * *f e

}

UNITED STATES NUCLEAR REGul.ATORY COMMISSION

/

n Q l

  • I Q

j REGION IV k,. 9

$11 RYAN Pt AZA DRIVE. SulTE 1000 AAUNG1cN. TEXAS 78011

~

0 5 rE31581 Cocket No. 99900507/81-01 i

7 Sargent i Lundy Engineers A1TN: Mr. R. 'd. Patterscn Senior Partner 55 East Monree Street Chicago, Illinois 50603 Gentlemen:

This refers to the inspecticn c:nducted by Mr. J. R. Ccstallo of dis office en January 19-23, 1980, cf your facility at Chicago, Illinois, and to te discussiens of our findings with Mr. J. E..N.cariand and memcers of ycur staff at the c:nclu-t sien of the insaectien.

Areas examined curing $ts ins:ecticn anc Our findings are ciscussed in me enclosed recer. 'ditnin these areas, me ins:ecticn c:nsistad :f an examina-tien of precacures and recresentative rec:rcs, intariiews witn persennel, and I

cbsertations by the inscec:cr.

Curing this inscecticn it was fcunc :nat you failed to meet cartain NRC require-l ments. The specific fincings and references to the pertinen: recuirements are identified in de enclosures to cis lettar.

Please provide us within twenty-five (25) days cf the data cf 2is letter a wri: en statament centaining, (1) a des:riptien of steps that have been er will be taken to c:rrect these itac;, (2) a descriction cf steos :nat have been or will be taken to prevent recurrence, and (3) ene dates ycur c:rnctive acticns and preventive measures. were Or will be c:moleted.

In acccrdance witn Secticn 2.790 of the NRC's " Rules of Practica, Part 2, i

Title 10, Ccde of Federal Regulaticns, a c oy of this letter and me enc!csed inscecticn recer will be 31acad in :ne NRC's Public Cccument Recm.

If the reper; c:ntains any infer naticn. hat ycu believe c be :recrie-tary, it is necessary mat ycu sucmi: a writter acclicatien o nis office within twenty-five (25) days of the data of tnis letter, recuesting such infor-matien be witaneld frem puclic disclosure.

The acclicatien mus: include a full statement of :ne reascns wny it is claimec ma:.he informatien is recrietary.

The acclicaricn shculd be precared sc da: any :recrietary inf:rnation identifiec is centained in an ancicsure to me acolicatien, sinca -he acclication witncut

=e enciesure will also be olaced in ce ?uclic Cccument Recm.

If we te not near fr:m ycu in.nis regard within te s:ecified period, ce recer will be placac in ne Public Cccumen: Recm.

e

?

8105180 L ${

P00R ORWL

l i

Sargent & Lundy Engineers 2

Should ycu have any questiens ccncerning this inspection, we will be pleased to discuss them with you.

Sincerel s

d b

UcisPotacovs,ln.ic.e'tur t

Vendor Inscoction Branch

Enclosures:

1.

Notice of Ncncenfonnance 2.

Inspecticn Reper: No. 999C0807/81-01 L

?00R OR8!NAL


~r