cRA l

f(' -

'e,,

UNITED STATES

.s., (, o NUCLEAR REGULATORY COMMISSION WW;i

{.

~y WASHINGTON, D. C. 20555 y

)k l@S l i

,' Docket No. 50-219 LICENSEE: JERSEY CENTRAL POWER & LIGHT COMPANY (JCP&L)

FACILITY: Oyster Creek Nuclear Generating Station

SUBJECT:

SUMMARY

OF MEETING HELD ON APRIL 15, 1981 TO DISCUSS JCP&L'S NEW CORE SPRAY SPARGER DESIGN AND PIPING MODIFICATION AT THE OYSTER CREEK NUCLEAR GENERATING STATION On April 15, 1981, a meeting was held in Bethesda, Maryland with representatives of JCP&L and their consultants. A list of attendees is provided as Enclosure 1, and the meeting agenda is listed on Enclosure 2.

The purpose of the meeting was to discuss the licensee's proposed core spray modification submittal; the princi-ple areas presented by the licensee included (1) structural analysis, (2) effects of sparger on piant operation, and (3) core spray performance.

The licensee stated that the inherent design of the sparger assembly will minimize the potential for damage during the removal and reinstallation phases.

Removal as an assembly will also provide a better means of inspection capability.

The selection of the nozzle manufacturer has not yet been finalized, however they expect tc make the selection in the near future. The licensee has indicated that they do not anticipate any major problems for the remainder of the modifi-cation work effort. The licensee was advised that the staff is presently reviewing the submittal in detail. Based on this review and the m'eeting discussion, a request for additional information will be prepared and forwarded to JCP&L.

The licensee stated that the planned test program for the new sparger system is scheduled for a September 1981 completion and the final modification report will be submitted in October. The delivery of all parts and equipment is expected in the October-November time frame. JCP&L indicated the probable need for another meeting with the staff in September 1981 to discuss the test results, overall program configuration, and schedule. The plant is scheduled for refueling outage beginning November 30, 1981 at which time the licensee intends to start the implementation of the core spray modification program.

r a

$L P vb /r./2.h Q

Walter A. Paulson, Project Manager Qames J.

oa rdo, Pro ect Manager Operating Reactors Branch #5 Operatin/ReactorsBranch#5 Division of Licensing Division of Licensing

Enclosures:

1.

List of Attendees 2.

Meeting Agenda cc w/ enclosures; See next page f

e Mr. I. R. Finfrock, J r.

CC G. F. Trowbridge, Esquire Gene Fisher Shaw, Pittman, Potts and Trewbridge Bureau Chief 1800 M Street, N. W.

Bureau of Radiation Protection Washington, D. C.

20036 380 Scotts Road Trenton, New Jersey 08628 G?U Service Corpcration ATTN: -Mr. E. G. Wallace Commissioner Licensing Manager New Jersey Department; of Energy 250 Cherry Hill Rcad 101 Cc.mmerce Street Partippany, New Jersey 07054 Newark, New Jersey 07102 Natural Resources Defense Council Plant Superintendent 917 15th Street, N. W.

Oyster Creek Nuclear Generating Washington, D. C.

20006 Station P. O. Box 388 Fcrkeo River, New Jer sey 08731 Resident Inspector c/o U. S. NRC P. O. Box 445 Ferked River, Nev Jer sey 08731 Joseph W. Ferraro, Jr., Esquire Deputy Attorney General Directer, Criteria ar d Standards State of New Jersey Division Ce;artment of Law and Public Safety Office cf Radiation F'rograms 1100 Raymond Boulevard (ANR-460)

Newark, New Jersey 07012 U. S. Environmental F"rotection Agency Ccean County Library Washington, D. C.

20:460 Brick Township Branch 401 Chambers Bridge Road U. S. Environrental P rotection Brick Town, New Jersey 08723 Agency Region II Office Maycr ATTN: EIS COURDINATOR Lacey Township 26 Federal Plaza P. O. Box 475 N?w Ycrk, New York 10007 Forked River, New Jersey 08731 Ccmmissioner Department of Public Utilities State of New Jersey 101 Centerce Street Nasark, New Jersey 07102

)

i l

LIST OF A1TENDEES y.

NRC D. Crutchfield W. Pasison J. Lombardo K. Wichman H. Shaw I

C. Y. Cheng R. Frahm G. Walton i

JCP&L' t

i J. Knubel l

D. Holland H. Williams J. Mandinelli J. Erbes F. Hong E. Romesberg i

J. Oates J. Kilty R. Furgeson J. Charnley MR.

S. Weems W. Schmidt NIAGAPA MOHAWK i

D. Greene W. D' Angelo l

J

,,