%4 p reg, gy UNITED STATES NUCLEAR REGULATORY COMMISSION g
7.
,e REGION 1 D[
631 PARK AVENUE 0,
,o KING OF PRUSSIA, PENNSYLVANIA 19406 Docket
- o. 50-354 g
91 Q.Jg
[
1-O
, J. .,, g /99g7 3 Public Service Electric & Gas Company ATTN: Mr. T. J. Martin r
A 5k whN%o Vice President Engineering and Construction 80 Park Plaza - 17C VA Newark, New Jersey 07101 Gentlemen:
Subject:
Potential Significant Deficiency of Biological Shield Thank you for your letter, dated December 29, 1980, which forwarded a final report pursuant to 10 CFR 50.55(e) regarding the subject matter.
This matter will be reviewed during a subsequent inspection.
Your cooperation with us is appreciated.
Sincerely,
_ m
/,
[obert
^
Carlson, Chief Reactor Construction and Engineering Support Branch l-cc:
J. Boettger, General Manager, Corporate QA 4
I i
8103100 lD
--