ML19345H484
| ML19345H484 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 04/16/1981 |
| From: | Crews J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Mattimoe J SACRAMENTO MUNICIPAL UTILITY DISTRICT |
| Shared Package | |
| ML19345H485 | List: |
| References | |
| NUDOCS 8105200409 | |
| Download: ML19345H484 (2) | |
See also: IR 05000312/1981012
Text
//C
>-
/
UNITED STATES
'
8
7.
NUCLEAR REGULATORY COMMISSION
$
E
REGION V
o
g
1990 N. CALIFORNIA BOULEVARD
g
SulTE 202, WALNUT CREEK PLAZA
- * * , 5 *&
4
- -
WALNUT CREEK, CALIFORNIA 94506
hI[/ h
\\
April 16,1981
g-4
-
Docket No. 50-312
(
N(Lh
i -)
-
-
p
L
,
i
MAY 19198W W
~
Sacremento Municipal Utility District
u.s. g 4W ""'
P. O. Box 15830
4
Sacramento, California 95813
si,
Attention: Mr. John Mattimoe
'
Assistant General Manager & Chief Engineer
Gentlemen:
Subject:
NRC Inspection of Rancho Sece
This refers to the inspection conducted by Messrs. H. Canter and J. O'Brien
of this office between March 1 and 31, 1981 of activities authorized by NRC
(License) No. DPR-54, and to the discussion of our findings held by Messrs.
H. Canter and J. O'Brien with Mr.P.Qubre' and other members of your staff at
the conclusion of the inspection.
Areas examined during this inspection are described in the enclosed inspection
report. Within these areas, the inspection consisted of selective examinations
of procedures and representative records, interviews with personnel, and ob-
servations by the inspector.
No items of noncompliance with NRC requirements were identified within the
scope of this inspection.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and the enclosed
inspection report will be placed in the NRC's Public Document Room.
If this
!
report contains any information that you believe to be proprietary, it is
necessary that you submit a written application to this office, within 20 days
of the date of this letter, requesting that such information be withheld from
public disclosure. The application must include a full statement of the reasons
why it is claimed that the information is proprietary. The application should
be prepared so that any proprietary information identified is contained in an
enclosure to the application, since the application without the enclosure will
also be placed in the Public Document Room.
If we do not hear from you in
this regard within the specified period, the report will be placed in the
Public Document Room.
i
8105200 N =
9
.
.
.
.
_
.
.
Sacramento Municipal Utility District -2-
. April 16, .1981
Should you have any questions concerning this inspection, we will be willing to
discuss them with-you.
Sincerely,
I ' A
s
6
J. L. Crews, Chief
Reactor Operations Projects
Branch
Enclosure:
IE Inspection Report
No. 50-312/81-12
Attachment 1, Nuclear Service
Raw Water Heat Exchangers -
1981 Refueling Outage Inspection
Results
cc w/o enclosure:
Standcrd Dist.
l
.
!
-.
- - . - . - - , - -
,
..- -.
. . .
- .
.
.