O ADMINISTRATIVE CONTROLS c.
chemistry and radiochemistry d.
metallurgy e.
instrumentation and control f.
radiological safety g.
mechanical and electrical engineering h.
quality assurance practices COMPOSITION 6.5.2.2 The ORC shall be composed of the:
Chairman:
Director of Nuclear Operations, Power Stations Department Vice Chairman:
Beaver Valley Power Station Project Manager Member:
Nuclear Engineer, Mechanical Engineering Department Member:
Beaver Valley Power Station Superintendent Member:
Instrument Engineer, P@er Stations Department Member:
Supervisor, Central Chemical Laboratory Power Stations Department Member:
Mechanical Engineer, Mechanical Engineering Department Member:
Quality Assurance Manager, Quality Assurance Department Member:
Superintendent of Licensing and Compliance, Power Stations Department
. Member:
Project Coordinating Engineer, Beaver Valley Project Team Member:
Health Physicist, Power Stations Depart: rent ALTERNATES 6.5.2.3 All alternate members shall be appointed in writing by the ORC Chairman to serve on.a temporary basis; however, no more than two alternates shall participate as voting members in ORC activities at any one time.
CONSULTANTS 6.5.2 A Consultants shall be utilized as determined by the ORC Chairman to provide expert advice to the ORC.
I i
BEAVER VALLEY - UNIT 1 6-8 PROPOSED WORDING
@l 0817 OlW
Description of Education nd Espericxe Related ta Fulfillment of Area o f T--h= 4 - = 1 Competaara Raouired as an CRC Member As of December 31. 1980 g
ORC Technical Area Education Directiv Ralated Work Experience J. A. Worling Nuclear Power Plant SS-Chemistry 1955 - 1959 Chemise operstices 1953 1959 - 1960 Shif t Reactor Engineer - Nuclear 1960 - 1962 Station operating Foremen - Nuclear 1962 - 1965 Station operating Engineer - Nuclear 1965 - 1971 Station operating Supervisor - Nuclear 1971 - 1975 Chief Engineer - Nuclear 1975-Present Station Superfacendent - Nuclear 25 years operations Division esperience 25 years Nuclear experience E. E. Martin N 1aar Engineering BS-ME 1950 - 1951 Station Operating Foreman - Nuclear 1949 1951 - 1960 Sts-don operating Engineer - Nuclear 1960 - 1961 Senior Engineer 1962 - 1971 Section Engineer - 7.P. Office 1971-Present Nuclear Engineer 22 years operations Division experience 9 years E&C Pivision experience 25 years Nuclear experience A. C. Masukaa Metallurgy BS-Chemistry 1948 - 1949 Chemical Analyst 1954 1949 - 1955 Field Chemist 1955 - 1955 Chemical Engineer 1955 - 1972 Metallurgical Engineer 1972 - 1974 Quality Assurance Supervisor 1974 - 1980 Quality control Supervison 1980-Present Supervisor, Chemical' Laboratory 33 yeets Operations Division experience 21 years Nuclear experience M. J.
Skoncey Insertsmentation and BS-EE 1973 - 1977 Engineer - Power Stations Control 1972 1977 - 1979 Instrument Foreman, Beaver Valley 1979-Present Instrument Engineer, PJWer Stations 8 years Operations Division experience 7 years Nuclear experience J. C. Allingham Radiological Safety BS-Physics 1957 - 1965 Radiation control Te-hairiaa 1965 1969 - 1971 Radiation control Supervisor 1973-Present Health Physicist (Cartified ABHP) 23 years Operations Division experience 20 years Nuclear experience F. Salmon Mechaataat Engineering BS-ME 1960 - 1964~
Project Eosineer 1949 1965 - 1968 Senior Ecaject Engineer i
1968 - 1973 Mechanical Station Engineer 1973-Present Mechanical Engineer 20 years E&C Division experience 13 years Nuclear experience l
E. A. YanWassen Electrical Engineering BS-EE 1951 - 1956 Senior %1ectrical Design Engineer 1947 1956 - 1966 Senior troject Engineer MS-EE 1966 - 1973 Supervising Engineer 1951 le73-Present Project Manager I
29 years E&C Division experience 25 years Nuclear experience
~
~
P00R ORIGINAle
Description of Education and P.xperience Islated to Tulfilbnt of Area of Techafe=1 Competence Required as an ORC Member (continued)
Name ORC Technical Area Education Directiv Related Work Experience
- 1. J. 2ashabaugh Quality Assurance 1954 - 1964 Construction Foresen Practices 1964 - 1965 Construction Inspector 1965 - 1970 Customer Laison Engineer 1970 - 1973 OLief Construction Inspector 1973-Present Quality Assurance Manager 26 years E&C Division experience J. J. carey as-EE 1958 - 1960 Test Engineer - Power Stations 1958 1960 - 1963 Chief Electrician - Phillips P.S.
1963 - 1966 Electrical Maintenance Insineer -
Power Stations 1966 - 1969 Stacion Superinundant - Elrama 1969 - 1971 shippingport Nuclear Training 3 rogram 1971 - 1974 Station Superincandant - Nuclear 1974 - 1979 Technical Assistant - Nuclear 1979-Present Director of Nuclear Operations 23 years Operations Division experience 12 years Nuclear er erience v
J. D. Sieber SS-ME 1961 - 1966 Test Engineer 196 1 1966 - 1968 P.catrument Engince.r 1968 - 1972 Training Engineer 1972 - 1979 Core Analysis Engineer 1979-Present Superintendent, Licensing & Compliance 17 years operations Division experience.
14 years Nuclear experience R. M. Mafrice Chemistry and SS-Chemistry 1957 - 1958 Test Engineer - Shf spinsport Radiochemistry 1956 1958 - 1960 Cha m t - Shippingport 1960 - 1961 Radioactive Weste Disposal Foreman 1961 - 1963 Paintenance 6 Operations Inetructor including: Raactor Engineer Shift Foreman Shift Operating Engineer 1963 - 1965 Senior Engineer - Shippingport 1965 - 1969 Senior Engineer - Power Stations 1969 - 1971 Turbine Engineer - Power Stations 1971 - 1979 Results Coordinator - Beaver 7 alley 1979-Present Onsite hgineering Group Supervisor and P eject Coordinating Engineer 22 pars Nuclear Operations experience 2 years Nucles.- Engineering experience Certified Operations Supervisor - Shippingport Atomic Power Station 4