Text

T L E /)

(Utu g

,o, UNITED STATES I

i NUCLEAR REGULATORY COMMISSION W ASHINGTON, D. C. 20555

\\...+./

January 29, 1981 Docket Nos. 50-317 and 50-318

~

g br s\\ ^

/

hY {%)f 7

g/

Mr. A. E. Lundvall, Jr.

g f ( _h, Vice President - Supply Baltimor? Gar Electric Company t;!

FEB 0 219816 g P. O. Box 475 Baltimore, Maryland 21203 4 v.s.=m ucurou g

co w ss a

Dear Mr. Lundvall:

4 A

By letters dated November 25 cnd December 30, vided clarification on the applicability of codes and standarcs to your dign and installation of the planned third auxiliary feedwater (AFW) train for each Calvert Cliffs unit.

Based on our review of these submittals, we understand that the third AFW train will, for each unit, consist of a motor-driven centr'/ugal pump, interconnecting piping and valves, and will be constructed in accordance with the ASME Boiler and Pressure Vessel Code,Section III, 1977 Edition, through the Sumer 1978 Addenda to the code. Class 2 components will be constructed in accordance with all the articles of ASME Section III, Subsection NC. The Class 3 components will be constructed in accordance with all the articles of ASME Section III, Subsection ND. Component supports will be constructed to comply with all the articles in ASME Section III, Subsection NF. All components will be installed in accordance with the code and addenda identified above except for the final connections to the existing AFW system which will be perforced to the original constuc-tion codes ANSI B31.1 1967 and ANSI B31.7 1967 including the 1970 addenda.

You indicate that neither your company nor your contractor performing the installation of the third AFW train possess a valid tertification of Authorization for use of the NA Code Symbol Stamp. Teerefore, the NA Stamp will not be applied to the appropriate components. However, to assure proper installation of components, Factory Mutual will provide a third party inspectio, We find that since the constructicn of the components for the third AFW train will be in accordance with the applicable codes and standards including Code Symbol Stamping, and installation will meet the specified code 8102190(pN f

s-

\\

Mr. A. E. Lundvall, Jr. requirements covering installation with the exception of the code symbol stamp, the planned construction and installat hn of the third AFW train for Calvert Cliffs Units Nos. 1 and 2 is acceptable.

Sincerely,

\\

. f

(

Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing cc: See next page i

I l

f I

Ba'1timore Gas and Elsetric Comhany ec:

James A. Biddison, Jr.

Mr. Bernard Fowler General Counsel President, Board of County G and E Building Commissioners Charles Center Frince Frederick, Maryland 20768 Baltimore, Maryland 21203 Mrector, Criteria and Standards Evision George F. Troweridge, Esquire OC' ice of Radiation Programs (AhT460)

Shaw, Pittman, Potts and U.'4. Enviro:inental Protection Agency Trowbridge Washington, D.C.

20460 1800 M Street, N.W.

Washington, D. C.

20036 U. S. Environmental Protection Agency Region III Office Mr. R. C. L. Olson ATTN:

EIS COORDINATOR Balt'uore Gas and Electric Company Curtis Building (Sixth Floor)

Roor 922 - G and E Building Sixth and Walnut Streets Post Office Box 1475 Philadelphia, Pennsylvania 19106 Baltimore, Maryland 21203 Mr. Leon B. Russell Ralph E. Architzel Plant Superintendent Resident Reactor Inspector Calvert Cliffs Nuclear Power Plant NRC Inspection and Enforcement P. O. Box 437 Baltimore Gas & Electric Company Lusby, Maryland 20657 Lusby, Maryland 20657

~

Bechtel Power Corporation Mr. Charles B. Brinkman Manager - Washington Nuclear ief Nuclear Engineer 15740 Shady Grove Road C

owe st us' Gaithersburc, Maryland 20760 Combustion Engineering, Inc.

4853 Cordell Ave., Suite A-1 l

Canbustion Engineerine, Inc.

Bethesda, Maryland 20014 l

ATTN: Mr. P. W. Kruse, Manager Engineering Services Post Office Box 500 Windsor, Connecticut 06095 Calvert County Library Prince Frederick, Maryland 20678 Director, Department of State Plannsng 301 West Preston Street Baltimore, Maryland 21201 Mr. R. M. Douglass, Manager Quality Assurance Department Administrator,' Power Plant Siting Program Room 923 Gas & Electric Building Energy and Coastal Zone Administration P. O. Box 1475 Department of Natural Resources Baltimore, Maryland 21203 Tawes State Office Building Annapolis, Maryland 21204 O

~

e mme =*

~ - - -,

,,,-.c.

,,..,.. _,. ~

, __,,,,