05000281/LER-1980-041-03, /03L-0:on 801112,snubber 2-WFPD-HSS-18 Found to Have Bent rod-eye & Was Declared Inoperable.Caused by Improper Alignment of Pipe Clamp to Snubber.Snubber Replaced

From kanterella
(Redirected from ML19345D869)
Jump to navigation Jump to search
/03L-0:on 801112,snubber 2-WFPD-HSS-18 Found to Have Bent rod-eye & Was Declared Inoperable.Caused by Improper Alignment of Pipe Clamp to Snubber.Snubber Replaced
ML19345D869
Person / Time
Site: Surry Dominion icon.png
Issue date: 12/11/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139A903 List:
References
LER-80-041-03L-03, LER-80-41-3L-3, NUDOCS 8012170636
Download: ML19345D869 (2)


LER-1980-041, /03L-0:on 801112,snubber 2-WFPD-HSS-18 Found to Have Bent rod-eye & Was Declared Inoperable.Caused by Improper Alignment of Pipe Clamp to Snubber.Snubber Replaced
Event date:
Report date:
2811980041R03 - NRC Website

text

40 FORM 36E U. b. NUCLh AN MtGUL AT ORY COMM!SSIOTv 771 LICENSEE EVENT REPORT CONTROL ELOCK. l

}

l l

l

! Ih (PLEASE PRINT OR TYPE ALL REOutRED INFORMATION) 1 6

1,1 i V I A I S l P l S l2 gl 0 j 0 ] - l 0 l 0 l 0 l 0 l0 l-l 0 l 0 lgl 4 l 1 l 1 l1 l 1 jgl l

lg 8 9 LICENSEE CODE 14 15 LICENSE NUMSE R 25 26 LICENSE TYPE 40 57 CAT 68 ON'T iTil

,"Co"' l L l@l0 i s to 1 01012 l 8 1 ligtlili112!8i0i@l i i 2 l 1 i i 18 jo l@

8 60 61 DOCKET NUMBER 65 69 Evf NT OATE 74 7b REPORT DATE 80 EVENT DESCRIPT!ON AND PROBABLE C0r' SEQUENCES h

) i2l l With the unit at 100% power, it was found that snubber 2-WFPD-HSS-18 had a bend rod-eye. l

Ihe snubber was declared inoperable. This is contrary to T.S. 3.20.A and is reportable 3

3,

per T.S. 6.6.2.b. (2). There were no events that required the snubber to perform its intended function during this pericd. Therefore, the health ard safety of the public wre not affected.

3171 l l

Oteii I

80 8 9 SYSTEu

CAUSE

CAUSE COMP.

VALVE CODE CODE SU8 CODE COMPONENT CODE SUSCODE SUSCODE o19l lC lH l@ j E lg lB l@ l 5 J U l P lO lR lT l@ [Djg lZ l g 8

9 10 11 12 13 18 19 20 SE QUENTI AL OCCURRENCE REPORT REVISION LE R.

EVENT YEAR REPORT NO.

CODE TYPE N O.

h,aEg'RO I810l l-l l 01411 l l/l l 01 31 IL l

[--]

l0 l u

_ 21 22 23 24 26 21 3

M 30 31 32 T

<N A

ON ON PLANT M

MOURS 22 5B I O

FOR B.

SUPPL R MAN FA RER lc lgl34 Ig I Z lg l Zig l7 0]0l0l l

l Yl@

l N i@

lA l@

lG l 215 l 5 l@

Z 33 36 36 3

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 3 ;O; lThe damage to the snubber's rod eye was caused due to the ims.w alignment of the pipe l g lclcup to the snubber. The snubber was replaced.

121 I I

i l 31 l l

i 1 64 11 l

8 9 80 STA

% POWE R OTHE R STATUS ISCC R OfSCOVERY OESCRIPTION i l 5 l l E l@ l 1l 0 l 0 l@l N/A l

l B l@l Routine inspection l

a

,!TiviTv caTENT AMOUNT O, ACriviTv @ l LOCATION OP REuASE @

2E u ASEe 07 RE u ASE N/A l

N/A l

l6 l l Z l h l Z l@l 1

8 9 10 11 44 45 go PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

j7l10]010l@lZ lhl N/A l

i PE RSONNE L INJURIE S NUMBER OESCRIPTION la l l 0 l 0 l0 l@]

N/A l

1 8 9 11 12 30 LOSS 05 OR DAMAGE TO FACILITY

} +N/A17h TYPE OESCRIPTION 7

l 9 l l Z l@l l

i 8 9 10 go Y

ISSUE DE CRIPTION e

2 I O l I N fhl N/A l

l1 lllllllllllj J. L. Wilson (804) 357-3184

[

-. -.. w.-

=.,

ATIX1 MENT 1, PAGE 1 T 1 SURRY POWER SIATION, UNIT 2 DOCKET NO:

50-281 REPORP NO:

80-041/03L-0 EVENT DATE:

11-12-80 TITT.E:

INOPERABLE SNUBBER 1.

DESCRIPTICN OF EVENT:

With the unit at 100% power, it was found by observation of mechanics working in the area that snubber 2-WFPD-HSS-18 had a bent rod-eye. 'Ihis is contrary to Technical Specification 3.20.A and is reportable per 'Ibchnical Speci-fication 6.6.2.b. (2).

2.

PROBABLE CONSEQUENCES AND STMUS T REDUNDANr.IYSTEm:

A snubber is a shock suppressor which is designed to prev ni damage to a pipe in the case of a seismic event or other shock.to the pipe. Dur W the period that the snubber's rod-eye was bent, there were no events that resulted in pipe damage. Therefore, the health and safety of thepublic were not affected.

3.

CAUSE

The rod-eye was deformed due to the hywg alignment of the pipe clamp to the snubber.

4.

IMMEDIATE 03RuunVE ACTION:

The imudiate corrective action was to have the condition of the snubber evalu2+4d by Engineering. The snubber was then declared inoperable.

5.

SUBSEQUENT COxxu;nVE ACTION:

The subsequent corrective action was to replace the inoperable snubber with a new snubber and properly align the pipe clamp.

6.

PION TAKEN 'IO PREVINT RECURRDCE:

1 None.