f.

.f I V

~

f '\\

Q Thomas J. Martin '

Public Service Electric and Gas Company 80 Park Place Newark, NJ. 07101 201/430-8316 i Vice President -

" Engineering and Construction August 7, 1980 s.

s

'Mr.

Boyce H..Grier, Director

-U.S.~' Nuclear Regulatory Commission

-Office.of: Inspection'and Enforcement

-Region 1 King-of' Prussia,-Pennsylvania-19406 r

Dear Mr. Grier:

BIOLOGICAL' SHIELD 10CFR50.55(e), POTENTIAL SIGNIFICANT DEFICIENCY NO.

1. UNIT-HOPE CREEK GENERATING STATION 1

F

~On July 1, 1980, a' verbal" report was made to Region 1, Office of Inspection and Enforcement representative, Mr. McGaughy, advising of-a. potential significant item.

The item.is Unit One's biological shield. supplied by PX Engineering Company.

-It was. reported that documentation (quality verification) for the lower subassembly:was found lacking-for inspection and NDE

.of-several welds.

The suspect welds may contain defects which could have gone undetected.

l The followingtsupplemental information is hereby submitted pursuant to our: initial report and in accordance with the require-ments of 10CFR50.55(e).

The Bechtel. Power Corporat'on, PSE&G's Architect Engineer, is currently conducting an investigation of documentation and effecting reexamination where appropriate.

The. determination of. corrective action necessary to resolve the-deficiencies. determined 'and to. access reportability in accordance.

with 10CFR50.55(e) is scheduledfor completion September 12, 1980, at'which; time a' report will be made to the NRC.

Very truly yours, f,

=CC Office of_ Inspection and Enforcement Division' of. Reactor : Construction ' Inspection

Washington,' DC-20555 800915 %

- i

-