ML19344E983

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Epoxy Surface Sys Whose Qualification Is Indeterminable Due to Conflicting Data in Qualification Test Repts & Data Not Supported by Actual Test Results. Investigation Is Continuing
ML19344E983
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 08/12/1980
From: Martin T
Public Service Enterprise Group
To:
References
REF-PT21-80-263-001 NUDOCS 8009120218
Download: ML19344E983 (2)


Text

-

s ~n.o n-avanv-n n.

. -.- c..

Pgf 21 IDBrilFICATIbN NO._ _ 70 - ab 3 -oo /

C0FPANY IWE PK M

+ha.

DATE OF LETTER.

S'/a/ F o D00(Ef NO.

Se-M4 DATE DISTRIBUTED 3/mo/ rr 8 ORIGIRAL REPORT SUPPlDENTARY >(.

/

DISTRIBlfTION:

REACTOR (R)g_

FUEL CYCE &

SAFEGUARDS (S)

IEID E IE FILES IE FIES AD/ROI (2)

IEFILES AD/SG AD/RCI ~

AD/ FREI AD/ROI

[GIONSI,II,III,IV,V REGIONSI,II,III,IV,V REGIGG I,II,III,IV,V VENDOR BR. R-IV VBBOR BR. R-I.V VENDOR BR, R IV WEB / FPA FIB 5715 NiES / FCES SS-396 NRR/ DOL AEOD FIB 7602 L0EB/FPA FTB 5715 teBS / SG SS-881 NRR/ DOE AEOD FIB 7602 LOEB / FPA FIB 5715 NRR/DSI ESBP FM 450 AE0D FIB 7602 NMT SAP /SP iTB-7210A ASLBP E/W 450 NRR/ DOL CENTRALFILES 016 CENTRAL FIES 016 ASLBP E/W 450 CENTPAL FILES ( GRON)

CBffRA' FILES (CHR000 CBffRALFILES 016 PDR CENTRAL FILES SS-396 CENTRAL FIES (GRDBD LPDR PDR PDR TERA IPDR LPDR TERA i

22A.

l

~ ACTION:

i PRELIMINARY EVALUATION OF THE' ATTACHED REPORT INDICATES LEAD RESPONSIBILITY FOR I

FOLLOWJ{ AS S}OhN BELOW:

IE y NRR[

NBBS [

OTHER [

JD l

ROI sa FFMSI Pa'. 8/1/80 o u o 9 1 2 0.21 T g

l.

V Thornas J. Martin Public Service Electric and Gas Company GO Park Place Newark, N.J. 07101 201/430-8316 Vica Pres 4ent Engineering and Construction August 12, 1980 Mr. Boyce h. Grier, Director U.

S.

Nuclear Regulatory Commission Office of Inspection and Enforcement C-26 3- 00 /

Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

CON / CHEM EPOXY SURFACER SYSTEM

~

10CFR21 ITEM NO. 1 UNT' HOPE CREEK GENERATING STATION Public Service Electric and Gas Company has been informad by Bechtel Power Corporation, our Architect-Engin'eer, that they have reported a 10CFR21 item to the Nuclear Regulatory,Comr:1ucion on July 23, 1980.

The reported item. concerns an Epoxy Surfacer System consisting of NC-30 Cono/ Weld, NC-40 Fibre / Crete and NC-50 Cono/ Glaze manufactured by Con /

Chem, Inc. of Hawthorne, Callicrnia.

Techtel reports that the qualification of the coating system is indeterathable due to conflicting data in qualification test reports and that Anformation 9xists that indicates qualification test data supplied,by,fC6n/ Chem were not supported by actual test results.

~

Investigation is continuing and should it be determined that the coating does not meet project requirements, appropriate corrective action will be taken.

PSE&G will keep your office informed of future developments.

Should any additior.1 information be desired, we will be pleased to dis-cuss it with you.

Very truly yours, ORIG. SIGNED BY

7. J. MARTIN

/

CC" Director Office of Inspection & Enforcement Washington, DC G.

B.

Jones Bechtel Power Corporation San Francisco, CA

?