,R
'g 633 PARK AVENUE KING OF PRUS$l A. PENNSYLVANI A 19406 AUG S 1980 Docket No. 50-293 IAL No. 80-26 Boston Edison Company M/C Nuclear ATTN: Mr. G. Carl Andognini, Manager Nuclear Operations Department 800 Boylston Street Boston, Massachusetts 02199 Gentlemen:
This refers to the telephone conversation between yori and Mr. E. J. Brunner of this office on August 5,1980, regarding testing of.the 'D' Safety Relief Valve (SRV)atPilgrimNuclearPowerStation, Unit 1.
With regard to the matters discussed, we understand that you will take the following actions:
1.
Perform Surveillance Testing to demonstrate the ability of 'D' SRV to open on demand at norma 1' operating pressure. This test will be performed prior to 11:59 PM, August 6, 1980.
2.
Continue trouble shooting to detennine the cause of the previous failures of 'D' SRV to open on demand.
3.
Perform additional Surveillance Testing on
'D' SRV at normal operating pressure following any work on the SRV control system.
If our understanding of your planned actions as described above is not in accordance with the actual plans and actions being implemented, please contact this office by telephone and in writing within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Sincerely,
-b: 'i j
t >(
Boyce H. Grier Director cc:
P. J. McGuire, Pilgrim Station Manager 8009120101 l