05000368/LER-1981-014, Forwards LER 81-014/03L-0

From kanterella
(Redirected from ML19343D621)
Jump to navigation Jump to search
Forwards LER 81-014/03L-0
ML19343D621
Person / Time
Site: Arkansas Nuclear 
Issue date: 04/24/1981
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19343D622 List:
References
NUDOCS 8105050587
Download: ML19343D621 (1)


LER-1981-014, Forwards LER 81-014/03L-0
Event date:
Report date:
3681981014R00 - NRC Website

text

.

b.

s i

ARKANSAS POWER & LIGHT COMPANY POST OFRCE BOX 551 UTTLE ROCK. ARKANSAS 72203 [50113716 April 24, 1981

'IQ'fx ep

- m

(

\\

2R-0481-08 Mr. G. L. Madsen, Chief d

d' fj Reactor Projects Branch NN s'

U. S. Nuclear Regulatory Comm.

\\jc6 flT 2 k Region IV 611 Pyan Plaza Drive, Suite 1000 Arlington, Texas 76011 SUBJECT: Arkansas Nuclear One-Unit 2 Docket No. 50-368 License No. NPF-6 Licensee Event Report No. 81-014/03L-0 (File: 2-0520)

Gentlemen:

In accordance with Arkansas Nuclear One - Unit 2 Technical Specification 6.9.1.9.b, attached is the subject report concerning a mechanical failure in a Emergency Feedwater pump (2P78).

Very truly yours, bY$

l David C. Trimble Manager, Licensing DCT:GAC:1p

' Attachment cc: Mr. Victor Stello, Jr., Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Comm.

Washington, D.C.

20555 l

Mr. Nonnan M. Haller, Director Office of Management and Program Analysis U. S. Nuclear Regulatory Comm.

Washington, D.C.

20555 3

8105050 N D

MEMBEA MIDOLE 4.OUTH UTIUTIES SYSTEM