ML19341B369

From kanterella
Jump to navigation Jump to search
Amends 61 & 58 to Licenses DPF-39 & DPR-48,respectively, Approving Guard Training & Qualification Plan & Combining Separate License Conditions for Security Plan,Safeguards Contingency Plan & Guard Training Plan
ML19341B369
Person / Time
Site: Zion  File:ZionSolutions icon.png
(DPR-39-A-061, DPR-39-A-61, DPR-48-A-058, DPR-48-A-58)
Issue date: 01/15/1981
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19341B368 List:
References
NUDOCS 8101300820
Download: ML19341B369 (4)


Text

-,

pa Kec UNITED STATES

?,,

NUCLEAR REGULATORY COMMISSION y

,rj( ) g WASHINGTON, D. C. 20555 g

j

%.~....j O

COMMONWEALTH EDIS0N COMPANY DOCKET N0. 50-295, ZION STATION UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 61 License No. DPR-39 The Nuclear Regulatory Commission (the Comission) has found that:

1.

The filing by Commonwealth Edison Company (the licensee) dated A.

16, 1979, as revised August 11, 1980, complies with the August standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and ~ regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the filing, the B.

provisions of the Act, and the rules and regulations of the Comission; There is reasonable assurance (i) that the activities authorized C.

by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; The issuance of this amendment will not be inimical to the comon D.

defense and security or to the health and safety of the public;.

and i

The issuance of this amendment is in accordance with 10 CFR Part E.

51 of the Comission's regulations and all applicable requirements l

l have been satisfied.

i f

i i

s10 2 30 0 RCS 1

1

- Accordingly, paragraph 2.C.(6) of Facility Operating License No.

2.

DPR-39 is hereby amended to read as follows:

Pursuant to the requirements of 10 CFR 50.34(c),10 CFR (6) 50.54(p) and 10 CFR 73.55, as applicable, the licensee shall fully implement and maintain in effect all provisions and changes to the following plans:

(a) Zion Station Unit Nos. I and 2 Physical Security Plan, approved March 14, 1979; (b) Zion Nuclear Power Station Safeguards Contingency Plan, approved November 17, 1980 and to be fully implemented within 30 days; (c) Zion Nuclear Power Station Guard Training and Qualification Plan approved January 15, 1981 and to be fully implemented within 60 days.

Also, paragraph 2.C.(9) has been replaced by the above paragraph and is 3.

therefore deleted.

Paragraphs 2.C.(7)(c), 2.C.(7)(d), and 2.C.(7)(c) are deleted.

4.

This license amendment is effective as of the date of its issuance.

5.

FOR THE NUCLEAR RE LATORY COMMISSION

,h b

,\\ C f

Operating Reactors Bra h.1 Division of Licensing Date of Issuance: January 15, 1981

gr,s regg o

UNITED STATES E'

'h NUCLEAR REGULATORY COMMISSION 3

wAsHmcTow, o. c. 20sss j

t g-9.....

O' 4

COMMONWEALTH EDIS0N COMPANY DOCKET NO. 50-304 ZION STATION UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 58 License No. DPR-48 1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

The filing by Commonwealth Edison Company (the licensee) dated August 16, 1979, as revised August 11, 1980, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the filing, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized ~

by this amendment can be conducted without endangering the health and safety of.the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon l

defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part f

51 of the Commission's regulations and all applicable requirements nave been satisfied.

I i

l

. 2.

Accordingly, paragraph 2.C.(6) of Facility Operating License No.

DPR-48 is hereby amended to read as follows:

(6) Pursuant to the requirements of 10 CFR 50.34(c),10 CFR 50.54(p) and 10 CFR 73.55, as applicable, the licensee shall fully implement and maintain in effect all provisions and changes to the following plans:

(a) Zion Station Unit Nos. I and 2 Physical Security Plan, approved March 14, 1979; (b) Zion Nuclear Power Statior Safeguards Contingency Plan, approved November 17, 1980 and to be fully implemented within 30 days; (c) Zion Nuclear Power Station Guard Training and Qualification Plan approved January 15, 1981 and to be fully implemented within 60 days.

3.

Also, paragraph 2.C.(9) has been replaced by the above paragraph and is therefore deleted.

4.

Paragraphs 2.C.(7)(c), 2.C.(7)(d), and 2.C.(7)(e) are deleted.

5.

This license amendment is effective as of the date of its issuance.

FOR'THE NUCLEA BECULATORY COMMISSION

}

1'

,.-.--i-.- -

< Steven A. V ga, Chief $(

.$&, b t Operating Reactors Bran [tt0#1 Division of Licensing Date of Issuance: January 15, 1981 t

e