B YANKEE ATOMIC ELECTRIC COMPANY 7h$
1671 Worcester Road, framingham, Massachusetts 01701 B.3.2.1
' YANKEE h *'
FYR 81-3 January 6, 1981 U.S. Nuclear Regulatory Coc: mission Washington, D.C 20555 Attention:
Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation
Reference:
(a) License No. DPR-3 (Docket No.50-29)
Subject:
Reactor Containment Building Integrated Leak Rate Test
Dear Sir:
Enclosed is our report " Reactor Containment Building Integrated Leak Rate Test" which su=marizes the test performed in September, 1980.
This report provides the evaluation of the Type A test results and a summary analysis of periodic Type B and Type C tests that were performed since the last Type A test in accordance with the requirement of 10CFR50, Appendix J, paragraph
/
V.3 3 If you have any questions or desire additional information, please contact us.
Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY
/
7 g{-
1 J. A. Kay Senior Engir er - Licensing pg, S3 0 A'J3",';E i JAK/kab
((I IT.I Bl NVI' IU@
mnc'-
~
- inuit:!a:M 810114 0M V
REACTOR CONTAINMENT BUILDING INTEGRATED LEAK RATE TEST s
SEPTEMBER 1980 YANKEE ATOMIC ELECTRIC COMPAhT ROWE, MASSACHUSETTS 01346 I
Prepared By:
M
, h( ope,3 Reviewed By:
f_ g 7( W,-../
Plant Reactor Engineer Approved By: 9 h
- Y.A,// 47id Plant Superintendent l
STrN l
..