ft,.,jo, UNITED STATES NUCLEAR REGULATORY COMMISSION cf e

a h

" ' :. Y WASHINGTON. D. C. 20655 ff

[

December 19, 1980 U

U Docket No. 50-302

'P 2

grl l,i Gil

~

M w

a

=

Mr. J. A. Hancock Director. Nuclear Operations Florida Power Corporation P. O. Box 14042, Mail Stop C-4 St. Petersburg, Florida 33733

Dear Mr. Hancock:

By letter dated December 19', 1980 you requested approval of BUNA-N sal material in the hydraulic snubbers at Crystal River Unit 3 until the next refueling outage (Fall 1981). Technical Specification 4.7.9.1(a) allows the use of materials other than ethylene propylene that are com-patable with the operating environment if the materials are approved by the NRC.

We have reviewed your request and have determined that you may use BUNA-N seal material in the hydraulic snubbers in accordance with Technical Speci-fication 4.7.9.l(a) until the next refueling shutdown. This short tem use is acceptable because the material is compatable with the operating environment and the hydrau11c fluid and the Crystal River plant is located in an area of infrequent seismic events. We understand that the BUNA-N seal material will be replaced with ethylene propylene seals during the next refueling shutdown.

Sincerely,

/

O Robert W. Reid, Chief Operating Reactors Branch #4 Division of Licensing cc:

See next page R 10114 0 6%

P

Crystal River Unit No. 3 50-302 Florida Power Corporation ccw/ enclosure (s):

Mr. S. A. Brandimore Mr. Robert B. Borstsn Vice President and General Counsel Babcock & Wilcox P. O. Box 14042 Nuclear Power Generation Division St. Petersburg, Florida 33733 Suite 420, 7735 Old Georgetown Road Bethesda, Maryland 20014 Mr. Wilbur Langely Chairman Board of County Commissioners Mr. Tom Stetka. Resident Inspector Citrus County U.S. Nuclear Regulatory Comission Iverness, Florida 36250 Route #3 Box 717 Crystal River, Florida 32629 U. S. Environmental Protection Agency Region IV Office ATTN:

EIS COORDINATOR 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Bureau of Intergovernmental Relations 660 Apalachee Parkway Director, Criteria and Standards Tallahassee, Florida 32304 Division Office of Radiation Programs -(ANR-460)

U. S. Environnental Protection Agency Washington, D. C. 20460 4

Crystal River Public Library Crystal River, Florida 32629 Mr. J. Shreve The Public Counsel Room 4 Holland Bldg.

Tallahassee, Florida 32304 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Attorney General i

Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Dr. William R. Stratton Los Alamos Scientific Lab Box 503 Los Alamos, New Mexico 87544

_, _