Forwards IE Info Notice 80-41, Failure of Swing Check Valve in Decay Heat Removal Sys at Davis Besse Unit 1. No Response Required
ML19340E089
Person / Time
Site: Zimmer
Issue date: 11/10/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
References
NUDOCS 8101060356
Download: ML19340E089 (2)


Text

-

  1. j s uc o

'o, UdlTED STATES 8".,

NUCLEAR REGULATORY COMMISSION e

REGION lli e,

[

790 ROOSEVELT ROAD g, -

f GLEN ELLY M. ILLINOIS 60137

  • ...+

November 10, 1980 Those on Attached Address Listing:

This IE Information Notice No. 80-41 is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the this office.

Sincerely, A wL, James G. Keppler [

Director

Enclosure:

IE Information Notice No. 80-41 cc w/ enc 1:

Mr. D. W. Kane, Sargent & Lundy Mr. Gary N. Wright, Chief Division of Nuclear Safety Reproduction Unit NRC 20b 81020603 %

p

g.

RIII's CORPORATE ADDRESSES FOR OPERATING LICENSEES AND CONSTRUCTION PERMIT HOLDERS (B'n'R's and PWR's) 1 Docket Nos. 50-10, 50-237, 50-249; 50-254, 50-265; 50-295, 50-304; 50-373, t

50-374; 50-454, 50-455; 50-456 and 50-457

-)

Commonwealth Edison Company Ij ATIN:

Mr. Cordell Reed, Vice President

-s

~

Post Office Box-757 A

Chicago, IL 60690 c5 cc w/ enc 1:

i Li;(l!

Mr. J. S. Able, Director Mr. Gunner Sorensen, Site

((

of Nuclear Licensing Project Superintendent Mr. D. J. Scott, Station Mr. R. Cosaro, Project Superintendent Superintendent Mr. N. Kalivianakis, Mr. J. F. Gudae, Station Station Superintendent Superintendent Mr. K. Graesser, Station Central Files Superintendent Director, NRR/DPM Mr. L. J. Burke, Site Director, NRR/ DOR Construction Superintendent AEOD Mr. T. E. Quaka, Quality Resident Inspectors, RIII Assurance Supervisor PDR Mr. R. H. Holyoak, Station Local PDR Superintendent NSIC Mr. B. B. Stephenson, TIC Project Manager Mr. Dean Hansell, Office of Mr. V. I. Schlosser, Assistant Attorney General Project Manager Myron M. Cherry, Chicago Mr. R. E. Querio, Station Superintendent Docket No. 50-358 Cincinnati Gas and Electric Company ATTN:

Mr. Earl A. Borgmann Senior Vice President s

Engineering Services and Electric Production 139 East 4th Street Cincinnati, OH 45201 cc w/ enc 1:

Mr. J. R. Schott, Plant Local PDR Superintendent NSI Central Files Director, NRR/DPM Harold W. Kohn, Power Director, NRR/ DOR Siting Commission AEOD Citizens Against a Radioactive Resident Inspector, RIII Environment PDR Helen W. Evans, State of Ohio

SSINS No..

6835 Accession No.:

8008220260 UNITED STATES IN 80-41 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 November 10, 1980 IE Information Notice No. 80-41:

FAILURE OF SWING CHECK VALVE IN THE DECAY HEAT REMOVAL SYSTEM AT DAVIS-BESSE UNIT NO. 1 Description of Circumstances:

On October 9, 1980 the resident inspector at the Davis-Besse facility was informed that the licensee had performed leak rate tests and identified exces-sive leakage through Decay Heat Removal System check valve CF-30.

Valve CF-30 is the inboard one of two in-series check valves that is used to isolate the reactor ' coolant system from the low pressure decay heat removal system.

On further investigation the licensee fot.nd that the valve disc and arm had separated from the valve body and was lodged just under the valve cover plate.

The two 2 5/8 x 5/8 inch bolts and locking mechanism for the bolts that holds the arm to the valve body were missing and have not been located.

The CF-30 valve is a 14-inch swing check valve manufactured by Velan Valve Corporation.

The cause of the failure has not been identified.

The test that was in progress when the failure was identified was being con-ducted in response to a letter from Darrell G. Eisenhut, Office of Nuclear Reactor Regulations to all Light Water Reactor Licensees, LWR Primary Coolant System Pressure Isolation Valves, February 23, 1980.

This IE Information Notice is provided as an early notification of a possibly significant matter that is still under review by the NRC staff.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or response is requested at this time.

If NRC evaluations so indicate, further licensee actions may be requested or required.

No written response to this IE Information Notice is required.

If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.