Forwards Response to NUREG-0694 Item 2.K.1 IE Bulletin on Measures to Mitigate Small Break LOCA & Loss of Feedwater Accidents. Util Has Developed Overlapping & Redundant Series of Procedures to Assure Engineered Safety Feature
ML19340C793
Person / Time
Site: Summer 
Issue date: 12/11/1980
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0694, RTR-NUREG-694 NUDOCS 8012170455
Download: ML19340C793 (5)


Text

O s3 SOUTH CAROLINA ELECTRIC a gas COMPANY d

b-Post errect ses 7s4

(,)

, qj CotuMe:A, South CAno LIN A 292t$

I. C NicHets, J R.

.3 y

g3, v.c

.....x.

..=c.3..c.m..s, December 11, 1980 3;g;u

%ca.. e......c..

n c:

il CD 5'

l tA un 9

Mr. Harold R. Denten, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 i

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 TMI Items II.K.1 (C.l.5) and I.C.6

Dear Mr. Denton:

As requested by the NRC, South Carolina Electric and Gas Company (SCE&G) acting for itself and agent for South Carolina Public Service Authority provides forty-five (45) copies of the SCE&G position on TMI items II.K.1 (C.l.5) regarding measures to citigate small break LOCAs and *? s of Feedwater Accidents and I.C.6 regarding guidance on procedures for verifyi.a correct performance. of operator activities.

Positions are given in attachments 1 and II.

If you have any questions, please let us know.

Very truly yours,

! f fg

/. 9 T. C. Nichols, Jr.

RBC:TCN:rh

Enclosures:

cc:

V. C. Summer w/o enclosures G. H. Fischer w/o enclosures T. C. Nichols, Jr. w/o enclosures E. H. Crews, Jr.

O. W. Dixon, Jr.

O. S. Bradham D. A. Nauman A. A. Smith A. R. Koon R. B. Clary W. A. Williams, Jr.

B. A. Bursey J. B. Knotts, Jr.

J. L. Skolds NPCF/Whitaker File i

i

'8012170 455 F)

ATTACHNENT I Page 1 of 1 NUREG-069'e-II.K.1 IE Bulletin on Measures to Mitigate Small Break LOCAs and Loss of Feedwater Accidents.

POSITION C.l.5 Review all valve positions, positioning requirements, positive controls and related test and maintenance procedures to assure prcper ESF functioning.

RESPONSE

Virgil C. Summer has developed an overlapping and redundant series of pro-cedures, (Administrative, Operating, Maintenance, Testing) to provide control of valve alignments, positioning requirements, and positive control requirements to assure proper ESF functioning.

Virgil C. Summer System Operating Procedures (SOPS) for safety related systems include valve checklists that specify initial vale alignment require-ments for system starti p.

The checklists have provision for sign offs for valve position verification, and second review of the completed checklists. Valve manipulations required dur ng the conduct of the procedure are specified within the body of the procedure as required so that the system is correctly aligned at all times for the curr at plant mode of operation.

All engineered safeguard systems are specificd in the Technical Specifications.

Surveillance Test Procedures (STP) have been developed which require verification of correct valve alignments by either visual observation or flow verification.

Such verification requires a sign off.

STPs which require val., manipulations are written in <

S a canner th - they require sign offs for each nanipulation plus a sign off verif'.catien at the completion of the test by an independent qualified operator that the valves have been restored to the system procedure designated status.

Administrative Procedures (AP) have been developed to contro? any alterations of safety related systems for test or maintenance. They insure that T(chnical Specification Limiting Conditions for operation are maintained or approyriate corrective action is taken. They require that an independent qualified person verify that the proper valve has been repositioned and that the proper valve is returned to the procedure designated status at the completion of maintenance activities to assure proper ESF system operability.

Requiremente for positive controls (locks on valves or electrical breakers) arc specified in the Technical Specifications and plant procedures. An Administrative procedure has been devleoped to control such locks and to verify on a periodic basis that they have not been tampered with. This control reinforces any other checks of the locked equipment required by SOPS, STPs or APs Shift relief procedures further require a walk down of the main control board to check the alignment of control board operated equipment.

l i

l t

i j

ATTAC10tE!Tf II Page 1 of 3 4

NUREG 0737 I.C.6

- Guidance on procedures for verifying correct performance of operator activitics, a

POSITION (1)

Applicability of the guidance of ANS 3.2, Section 5.2.6, should be extended to cover surveillance testing in addition to maintenance.

RESPONSE (1)

Instructions dealing with equipment control are basically included in four (4) Station Administrative Procedures. These are AP-204.1, " Safety Tagging";

AP-217, " Removal and Restoration of Station Equipment"; AP-401, " Maintenance Work Request"; and AP-801, " Surveillance Test Program".

Station Administrative Procedure AP-217, " Removal and Restoration of Station Equipment", addresses equipment control from the standpoint of placing equipment in and out of service. This procedure designates the Operations Shif t Supervisor (SRO Certified) as having responsibility for granting permission to release plant systems or equipment for maintenance or surveillance testing. This procedure requires a verification that the equipment or system can be released, a determin-3 ation of how long it may be out of service, and a determination of what functional cesting of redundant systems is required prior to and during the out-of-service period. Granting of such permission is documented and attention is given to the potentially degraded degree of protection when one subsystem of a redundant safety system has been removed for maintenance or surveillance testing. This procedure requires the Control Room Operator (Reactor Operator) to perform an independent verification that the conditions and actions specified are correct.

Statior Administrative Procedure AP-204.1, " Safety Tagging", contains ceasures which provide for protection of equipment and workers. Strict control measures for affected equipment are enforced. These control measures include locking and/or tagging to secure and identify equipment.

AP-217 requires that prior to removal of equipment or cystems from service, conditions such as Technical Specifications and the overall affect on Plant operations be considered.

Station Procedure AP-204.1 includes requirements for insuring that proper valve lineups are identified and perfermed and that proper control measures are established as required.

Station Administrative Procedure AP-401, " Maintenance Work Request", addresses performing temporary modifications, such as temporary bypass lines, electrical jumpers, and lifted electrical leads.

Status and control of such temporary modi-fications are maintained under the hbintetance Work Program. This procedure re-quires that a functional test be performec to conclusively prove the proper install-ation or removal of temporary modifications.

The status of inspections and tests performed upon individual equipment and/or systems is compiled and updated on a daily basis. Each piece of Station equipment has a unique identification number which is traceable to records of the status of inspections and tests.

4+

m

- m.

m

=_-

d ATTACl[ MENT II Page 2 of 3 Station Administrative Procedure AP-801, " Surveillance Test Program",

addresses the process of identifying and handling items which have not satis-factorily passed requirod inspections and tests. Until suitable documentary evidence is available to show that equipment or material is in conformance, affected systems shall be considered to be inoperable and reliance shall not be placed on such systems to fulfill their intended safety function.

Station Administrative Procedure AP-401 addresses returning equipment to service. This procedure requires Operations to accept items when they are ready to be returned to service.

Functional acceptability of the equipment is required.

Removal of temporary jumpers, signals, etc. used during maintenance and testing is also addressed in AP-401.

Station Administrative Procedure AP-204.1 will require an independent verification by a second qualified person of proper alignment of equipment important to safety prior to return to operation. Also, Station Administrative Procedure AP-217 requires that the proper surveillance testing be performed when equipment is placed into service.

It should be noted that Virgil C. Summer Nuclear Statica will have nutenatic system status monitoring as discussed in Task Action Plan items I.D.3, NUREG-0660.

POSITION (2)

In lieu of any designated Senior Reactor Operator (SRO), the authority to release systems and equipment for maintenance or surveillance testing or return-to-service may be delegated to an on-shif t SF0, provided provisions are made to ensure that the Shift Supervisor is kept fully informed of system status.

RESPONSE (2)

Station Administrative Procedures AP-217, "Remc al and Restoration of Statior.

Equipnent", and AP-204.1, " Safety Tagging", detail administrative controls for trNing systems out-of-service and return-to-service.

Botl, procedures are being revised to define the authority of the Control Room Foreman (second SRO on-shift) via the Shift Supervisor and his responsibility in keepin, the Shift Supervisor appraised of plant / system status.

The responsibility anu authority to release systems for maintenance or testing and to return systems to service currently is held by the on-shift Shift Supervisor and designated shift members only. Other personnel not assigned to operating shifts such as Training Instructors and Plant Engineers who are in the Operator License Training Program do not have and will not have this authority.

l POSITION (3) l Except in cases of significant radiation exposure, a second qua13fied person should verify correct implementation of equipment control measures such as tagging of equipment, j

RESP 0NSF (3) r AP-204.1 " Safety Tagging", is being revised to require a second independent verification of proper implementation cf equipment cettrol measures such as equip-ment tagging by a Licensed Operator. This presently means an Operator in the l

Cold License Training Program.

l l

-u-------e

-t,-

1w-wt*

e-w-'a<r

~,.

c' tv--

e r

--r,.w,.y--,,,e ym-y7y, 2--

w-a v-%y vy-*-,

---g-w-e,wy----

_g.--y--

--r--

gr----+---M-+=r-- t-w-

-- +-

- _ ~.

I ATTACID!ENT II i

Page 3 of 3 POSITION (4) i Equipment control procedures should include assurance that Control-Room Operators are informed of changes in equipment status and the effects of such changes.

RESPONSE (4)

AP-217, " Removal and Restoration of Station Equipment", currently reflects a requirement that the Control Room Operator review and signoff prior to removing equipment from service or returning it to service. The form defines why the equipment is out of service, what changes are to be made to the system, and its impact on Technical Specifications or redundant system. AP-1500, " Plant Modi-fications", is under development. This procedure will insure by signnff that when modification changes are made to systems, the Operators receive training of the changes and any revised precedures as a result of those changes.

POSITION (5)

For the return-to-service of equipment important to safety, a second qualified Operator should verify proper systems alignment unless functional testing can be performed without compromising plant safety, and can prove that all equipment, t

i valves, and switches involved in the activity are correctly aligned.

RESPONSE (5)

For initial system startup af ter a maintenance refueling outage, a system valve and c.ectrical lineup is required. These lineups are documented on check-lists with signoffs. The checklists are reviewed by a second qualified Operator and signed aff. The second Operator may, but is not required to, do another independent ;bysical valve alignment verification. To be declared operable, a l

system important to safety must have a current acceptable surveillance test performed.

AP-?l7, " Removal and Restoration of Station Equipment", details the requirements for restoring systems important to safety to operable after t maintenance or tetting outage.

It provides for QC acceptance if necessary, retest or functional verilication if necessary, and surveillance testing if necessary.

j AP-201.1, " Safety Tugging", is being revised to require a second independent qualified Operator vo-ification of removal of safety tags and restoration of valves and equipment to proceture designated status.

AP-401, " Maintenance Work Request",

requires specifying and signoff of functional testing and verification by Plant Operators before releasing the Work Request.

It also requires signoff by the Shift Supervisor that the work has been completed, all required tests and signoffs have been completed, and is acceptable to him. Preventive maintenance tasks have a computerized cover sheet that requires Shift Supervisor approval prior to starting the task and Shif t Supervisor acceptance at the end of the task.