Forwards QA Program Insp Repts 99900092/80-01 & 71-9016/80-01 on 800707-11 & Notice of Deviation
ML19340B105
Person / Time
Site: 07109016
Issue date: 08/01/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Robatel M
ROBATEL SLPI GENAS, FRANCE
Shared Package
ML19340B102 List:
References
REF-QA-99900092 NUDOCS 8010210248
Download: ML19340B105 (2)


Text

._

.v sp Rtc p

-)

p %'

UNITED STATES yi g

NUCLEAR REGULATORY COMMISSION 3

~ ti. *

'j REGION IV 0,

4 611 RYAN PLAZA oRIVE, SulTE 1000

.g' ARL8NGToN, TEXAS 76012 01 AUG G80 Docket No.-71009016/80-01 99900092/80-01 l

Robatel-SLPI ATTN:

Mr. M. Robatel President and General Director Boite Postale 20 Genas, France 69740 a

Gentlemen:

j This _ refers to the QA Program inspection conducted by Mr. W. M. McNeill of this l

office on. July 7-11, 1980, of your facility at Genas, France associated with the manufacture and fabrication of spent fuel shipping cask and to the discussions of.our findings with you and members of your staff at the conclusion of the inspection.

4 1

This inspection was made to confirm that, in the areas inspected, your QA Program j

is_being effectively implemented. The inspection effort is not designed to assure j

that unique quality requirements imposed by a customer are being implemented; 1

nor.to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each

~

l of its licensees to assume full responsibility for the quality of specific products, components or-services procured from others. You should'therefore r

not conclude that the NRC's inspection exempts you from inspections by an NRC l

licensee or his agents nor from rah ng effective corrective action in response j

to.their findings.

l t

Areas exanined and our findings are discussed in the enclosed report. Within these areas,. the. inspection consisted of an examination of procedures and repre-

l sentative records, interviews and personnel, and observations by the inspector.

During the' inspection it was found that the implementation of your QA Program failed-to meet certain NRC requirements.. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please. provide us within thirty (30) days of your receipt'of this report a written statement containing, (1) a description of steps that have been or will

. be taken to correct these ' items, (2) a description of steps that have been or

.will be taken to prevent recurrence, and (3) the date your corrective actions and preventive measures were or will be completed.

a i

8010210248

Robatel-SLPI In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection' report will be placed-in the Commission's Public Document Room. If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claired that the informa-tion is proprietary, and should be prepared so tha: proprietary information identified in the application. is courninM in a separate part of the document..

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased-to discuss them with you.

Sincerely, f

(

y 1

g4' Ul'd

otapovs, i

Vendor Inspection Branch

Enclosures:

1.

Notice of Deviation 2.

Inspection Report No. 71009016/80-01 99900092/80-01

- ~,