ML19340A856

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in IE Insp Repts 50-010/76-26,50-237/76-27 & 50-249/76-29.Corrective Action:High Radiation Door Locks Changed & Locking Mechanisms No Longer Can Be Left Closed While Unlocked
ML19340A856
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 02/28/1977
From: Bolger R
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19340A841 List:
References
NUDOCS 8009040673
Download: ML19340A856 (1)


Text

.

Comm*.nwe:lth Edis;n s

m3 Oni First National Plaza. Chicago, lil:nois Address Reply to: Post Office Box 767 Chicago, Illinois 60690 February 28, 1977 Mr. James G. Keppler, Director

~

Directorate of Inspection and Enforcement - Region III U.S. Nuclear Regulatory Commission _ _

799 Roosevelt Road Glen Ellyn, Illinois 60137 1

Subject:

Dresden Station Units 1, 2, and 3 IE Inspection Reports 50-10/76-26, 50-237/76-27, and 50-249/76-29 NRC Docket Hoc. 50-10/237/249 References (a):

J. Allan (NRC) Letter to Syron Lee (CECO) dated January 14, 1977 - NRC Docket Nes.

~

50-10/237/249.

(b):

R.

L.

Bolger (CECO) Letter to J. G.

Keppler (NRC) dated February 4, 1977.

Dear Mr. Keppler:

Re ference (b) was written in response to Reference (a) con-corning unlocked and unattended high radiation doors at Dresden Station.

This letter will supplcment our response since, upon further review, it has boon decided to change the high radiation door locking mechanisms as follows:

The majority of Dresden's "High Radiation Areas" have door locking mechanisms that allow the doors to be closed in the unlocked position.

Maintenance requests have,been initiated to change the locking mechanisms on all such/ doors so that they may not be left closed in the unlocked position.

The lochs on doors to frequently used "High Radiation Areas" will be changed by April 10, 1977.

The locks on doors to other less frequently used "High Radiation Areas" will be changed as soon as practical with a completion target of December 1977.

The list of doors to the frequently used "High Radiation Areas" will include the Unit 2 moisture separator room, the Unit 2 high pressure heater /X area, and the Unit 2 turbine pipeway.

Please address any additional questions on this matter to this office.

Very ruly yours,

/

R.

L.

Bo or Assistant Vice President 80090gg g