Forwards Proposed Amend to License SNM-1275,Section 3.1.2 Re Water Sources
ML19340A468
Person / Time
Site: Crystal River 
Issue date: 09/23/1975
From: Rodgers J
FLORIDA POWER CORP.
To:
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 8003260810
Download: ML19340A468 (2)


Text

_

..N,.

. YEAW ;

s.

Florida Power September 23, 1975 C O *

  • O a A f 6 0 e.

i Ofs

,1 f

Director i

  1. v U.

9'7 Division of Materials Licensing N

U. S.. Nuclear Regulatory Commission gyi' Washington, DC 20545 In Re: Florida Power Corporation Crystal River Nuclear Generating Plant

( N ket No. 50-3{2}

Dear Sir:

Enclosed are one (1) executed original and five (5) copies of Florida Power Corporation's Application for Amendment to our Special Nuclear Material License No. SNM-1275 for Crystal River Unit #3.

This license authorizes the receipt, possession, inspection, storage, and packaging for transport of enriched uranium in the form of reactor fuel assemblies, and the receipt, possession, and storage only of Americium-beryllium-curium neutron sources.

The proposed modification is to Section 3.1.2 Sources of Water on page four of our Application for a Special Nuclear Materials License which

- was filed with the Comission on August 23, 1971 and subsequently revised on November 26, 1974 and August 6, 1975.

The revised page to this application contains a date of revision and a vertical line in the right margin identifying the modification made to the existing page.

As we are currently planning to receive the first fuel shipment on October 9,1975, we stand ready to expedite this amendment to our application in order to avoid potential schedule problems.

Very truly yours, JTR:1dh J.

. Rodgers Assistant Vice resident enc.

s

\\'

1.E 70 8003260 P/ O g General Office 32ai Th.rty-fourtn street sourn. P o co 14c42. st Peterst rg Ficrida 33733 813 - 666 5151

m

~

3' STORAGE CONDITIONS 3.1 STORAGE AREA-The fuel will be stored in' the permanent new.ifuel and spent fuel storage

~

~ areas; located in 'the plant auxiliary building.(3) r

'3.1.1

-FIRE PROTECTION' Thel Auxiliary Building,. storage racks and fuel assemblies are to be constructed of non-flammable materials which makes fire in the storage area extremely unlikely.

Nevertheless, portable fire extinguishers will'be provided for fire protection.

3;1.2 SOURCES OF WATER The top of the Fuel Storage pit floor is located at an elevation of 162 ' feet,-

plant datum, with the highest expected flood water elevation being'121.4 feet.

Therefore, the. fuel-pits are not# subject to flooding. While storing new fuel,

~

all water supply sources will be' secured and pit drain systems will be left l'

~

~

ce open. The' fuel storage' rack spacing provides a safe geometry for the ' assemblies y.1 l even in the' event of flooding.

o t-f

3. l'. 3 '

CONTROLOF,ACCkSS

- Access to the Fuel' Storage' area will. be available only through metal gates 1

land /or.: doors'which will 'bel closed andzlocked With heavy dutyJ security l'ocks-

.y

~

>-4 Revised (9/23/75) f_

6-t u

3 x

v

+ b'S

~

h *._ '

X=

u.

'