d im-t SUPPLEMENTARY INFORMATION m

Report No.:

50-302/77-111E 8

. Facility:

Crystal River Unit #3

)

1..

Report Date:

21 September 1977 Occurrence Date:

January 1,- July 31, 1977 (discovered 6 September 1977) '

Identification of Occurrence:

i Environmental samples were not analyzed using procedures which provided LLD's equal j

to or less than those required by the Environmental Technical Specifications.

j

..-Conditions Prior to' Occurrence:

NA Description of Occurrence:

j.

The following samples had LLD'n greater than that required by ETS for the~ dates indicated below:

)

3 Air - 1/14/77 Gross Beta - 1 LLD ETS L

. Sea Water Jan.

Feb. Mar.

April May

' June

-July i

J (f > ETS) 24 16 7

7 11 11 12 i

I Milk June July i

?

(f> ETS) 17 3

'l l-j Designation of Apparent Cause:'

Inadequate ' techniques, procedures, and/or equipment to achieve the requ' ired LLD's i

Analysis of Occurrence:

{

The average concentrations of the nuclides whose LLD's were greater. than ETS for

~l each Sample S,tation were below the preoperational 95 percentile concentration.

Therefore, there has been no undetected damage to the environment adjacent to Crystal River Unit f3.

Corrective Action:

4'

_ Analysis procedures are being revised to allow for longer count -times and better 1

calculations of. background counts. These will lead to LLD's which should be below the ETS' limit.

)-

.- Failure Data:

This is the first report for this type.of occurrence.

8003260 72 f

. - _..., _.... - -.. ~....