ML19339A899

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 770610-17
ML19339A899
Person / Time
Site: Yankee Rowe
Issue date: 07/13/1977
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19339A891 List:
References
50-029-77-11, 50-29-77-11, NUDOCS 8011050661
Download: ML19339A899 (1)


Text

_._

(

Q License No. DPR-3 APPENDIX A NOTICE OF VIOLATION

=

.. h h

9 Based on the results of the !!RC inspection conducted on June 10-17, 1977, it appears that certain of your activities were not conducted in

=5-full compliance with conditions of your f;RC Facility License No. DPR-3 as indicated below. These items are infractions.

3 0.1 A v A.

Technical SpecificationQ.b.2.1.cNtates in part, that:

"The accuracy of each Type A test snail be verified by a supplemental test which requires the metered mass of gas injected into the

==

containment...for the supplemental test to be equivalent to between 50 and 100% of the allowable 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> mass loss."

Contrary to the above, the mass of gas infected into containment 5.[

for the supplemental test conducted on June 13, 1977, was equiva-g_=

lent to 38.7% of the allowable 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> mass loss.

~'

g=:=E B.

Technical Specification 6.8.1 states in part, that:

" Written pro-

~

cedures shall be established, implemented, and maintained...."

=

Procedure No. OP-4701, Revision 3, dated January 10, 1977, step 8, requires the hourly recording of instrument readings on Attachment i

A.

Contrary to the above, at 2300 and 2400 on June 11, l977, and at 1

0400, 0600,1100, and 1200 on June 12, outside weather instrument readings were not recorded.

,i;;

7

[l r

i I'

-=

.