ML19338G599

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 70-1151/80-20 on 800721-25 & Notice of Violation.Notice of Violation Withheld (Ref 10CFR2.790)
ML19338G599
Person / Time
Site: Westinghouse
Issue date: 08/29/1980
From: Kenna W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Damore M
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML19338G592 List:
References
NUDOCS 8010310322
Download: ML19338G599 (2)


Text

MATERIAL TRANSMITTED HEREWiT' CONTAlHS 2.790 INFOREWON o

UNITED STATES 8

~,%

NUCLEAR REGULATORY COMMISSION i

U E

REGION 11 k

101 MARIETTA ST., N.W.. SUITE 3100

  1. g o

ATL ANTA. GEORGIA 30303 In Reply Refer To:

[. ' ' O ~ '

RII:JWB 70-1151/80-20 Westinghouse Electric Corporation ATTN:

M. D'Amore, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, SC 29205 Gentlemen:

This refers to the routine inspection conducted by J. W. Bates of this office on July 21-25, 1980, of activities authorized by hTC License No. SNM-1107 at Westinghouse Electric Corporation and to the discussions of our findings held with W. J. Hartnett at the conclusion of the inspection.

Areas examined during this inspection included your program for nuclear material control and accountability under the applicable provisions of Title 10, Code of Federal Regulations, Part 70, "Special Nuclear Material,"

and specific license conditions. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, performance tests, and observations by the inspector.

We have examined actions you have taken with regard to previously identified enforcement matters. These are discussed in the enclosed inspection report.

During the inspection, it was found that certain activities under your license appear to be in noncompliance with NRC requirements. These items and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Appendix A.

This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulat hns.

Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:

(1) corrective steps which have been taken to avoid further noncompliance; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved. Details of activities involving safeguards and security measures are exempt from disclosure in accordance with 10 CFR 2.790(d). Therefore, your tesponse should be incorporated in a separate paper and referenced in your reply.

.w g e 1 0 3 g 2.2.

mT31AL TR.tNSMITTED HEREWITH CONTAliiS 2.793 fHf0RMAT10N

N EFRIALTRANSkilTTED HER. TITH CONTAINS 2.790INFORMATION Westinghouse Electric Corp..

In accordance with Section 2.790(d) of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, activities involving safeguards and security measures are exempt from public disclosure; therefore, the enclosures to this letter with the exception of the report cover page, which is an inspection summary, will not be placed in the Public Document Room.

Should you have any questions concerning this letter, we will be glad to discuss them with you.

Sincerely,

& w-

. B. Kenn)t, Chief Safeguards Branch

Enclosures:

1.

Appendix A, Notice of Violation (Exempt from Disclosure) 2.

Inspection Report No. 70-1151/80-20 (Exempt from Disclosure) 3.

Inspection Summary (Not Exempt) 1 I

WTERIALTRANSMITTED HEREWITH CONTAINS 2.790 IMFORETM