ML19338G611
| ML19338G611 | |
| Person / Time | |
|---|---|
| Site: | Westinghouse |
| Issue date: | 08/29/1980 |
| From: | Bates J, Gillespie F NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| Shared Package | |
| ML19338G592 | List: |
| References | |
| 70-1151-80-20, NUDOCS 8010310340 | |
| Download: ML19338G611 (1) | |
Text
WTENETPN I
$ (
4'pe n;uq'o.-
UNITED STATES
)
CONTAINS 2.7s,3 IMCRMATDi(
E' N
NUCLEAR REGULATORY COMMISSION
,E REGION 11 l
/[
4 o,
101 MARIETTA sT.. N.W., SUITE 3100 ATLANTA, GEORGIA 3o3o3
{
AUG 2 91980 Report No. 70-1151/80-20 Docket No. 70-1151 License No. SNM-1107 Safeguards Group III Licensee: Westinghouse Electric Corporation Nuclear Fuel Division Columbia, SC 29205 Facility Name: Westinghouse Electric Corporation Inspection at: Columbia, SC Inspection conducted: July 21-25, 1980 Date of Last Material Control and Accounting Inspection Visit:
6/24-26/80
~////
[m f
9 8
Inspector: /
g,7W. Bates, Chemist D'at Approved by:
t 2
/3 sF. P/./ Gill spie, Chief, MC&A Section,
/Date' Syfeguards Branch Inspection Summary Areas Inspected: The Westinghouse measurement control program and followup on items of noncompliance.
The inspection involved 40 inspector-hours onsite by one NRC inspector and was begun during the regular hours.
Results: The licensee was found to be in compliance with NRC requirements in the two areas examined during the inspection except for the following two items:
1.
Deficiency - Failure to make mixing / sampling test for two UNH storage tanks and the service tanks (80-20-01).
2.
Deficiency - Failure to establish, maintain and follow, a system for the measurement of all SNM removed from inventory (80-20-02).
1
\\
lOY S-F2 1LO Copy of Copies
/ f Pages This Docurent is not to be
- "d" *d " *"**P* *
- ETERl/1TRA. SMITTED HEREWITH BPProval of IE:II,. ~... -
Y 80108103gO cohwas 2.m waamTBN,