ML19338F874
| ML19338F874 | |
| Person / Time | |
|---|---|
| Site: | Perkins, Cherokee |
| Issue date: | 10/02/1980 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Dail L DUKE POWER CO. |
| References | |
| NUDOCS 8010270544 | |
| Download: ML19338F874 (1) | |
Text
o nery f'
8 D
UNITED STATES 8
"u NUCLEAR REGULATORY COMMISSION n
5
,E REGION 11 k
k 101 MARIETTA ST N.W., SulTE 3100 o
ATLANTA, GEORGIA 3o303 OCT 2 1980 In Reply Refer To:
RII:JPO 50-491, 50-492 50-493,
-488)
<sIF489?_ -49 J Duke Power Company ATTN:
L. C. Dail, Vice President Design Engineering P. O. Box 33189 Charlotte, NC 28242 Gentlemen:
The enclosed IE Circular No. 80-22, is forwarded to you for information.
No written response is required. Should you have any questions related to your understanding of the recommendations on this matter, please contact this office.
Sincerely, wT James P. O'Reiny Director
Enclosures:
1.
IE Circular No. 80-22 2.
List of Recently Issued IE Circulars cc w/ encl:
J. T. Moore, Project Manager e
u
n..
SSINS: 6830 Accession No. :
8006190055 UNITED STATES Aj#
NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT
[
WASHINGTON, D.C.
20555 October 2,1980 IE Circular No. 80-22: CONFIRMATION OF EMPLOYEE QUALIFICATIONS In recent months, the Nuclear Regulatory Commission has determined that in two unrelated actions a utility and an architect-engineering company employed tech-nically unqualified individuals as designers / engineers by failing to confirm the validity of their technical and educational qualifications as presented in their employment applications.
In both of these instances, the employers mistakenly assumed that the personnel firms supplying these individuals had investigated and confirmed previous career experiences. In view of the fact that the unquali-fied persons in both of these cases were discovered as a result of allegations to this effect, rather than through internal company procedures, we believe that this matter warrants your attention.
We are hereby recommending that your employment procedures be reviewed to deter-mine that your company has in effect employment policies which confirm the professional qualifications of employees.
In the e.ent you conclude that your present procedures do not fully address this matter, we recommend that you take prompt remedial action in this regard.
No written response to this Circular is required.
If you desire additional information regarding this subject, contact the Director of the appropriate NRC Regional Office.
I 1
g IEC 80-22 October 2, 1980.
RECENTLY ISSUED IE CIRCULARS 4
Circular Date of No.
Subject Issue Issued to 80-22 Confirmation of Employee 10/2/80 All holders of a power Qualifications reactor OL or CP 80-21 Regulation of refueling 9/10/80 All holders of a crews power reactor OL or CP.
80-20 Changes in Safe-Slab Tank 8/21/80 All Part 50 and Part Dimensions 70 fuel facility licensees 80-19 Noncompliance with 8/26/80 All medical licensees License Requirements for Medical Licensees 80-18 10 CFR 50.59 Safety 8/22/80 All power reactor Evaluations for Changes to facilities with an Radioactive Waste Treatment OL or CP Systems
~
80-17 Fuel Pin Damage Due to Water 7/23/80 All holders of PWR
~
Jet from Baffle Plate Ccrner OLs and'PWR cps 80-16 Operational Deficiencies In 6/27/80 All power reactor Rosemount Model 510DU Trip facilities with an Units And Model 1152 Pressure OL or a CP i
Transmitters 80-15 Loss of Reactor Coolant Pump 6/20/80 All power reactor Cooling and Natural Circula-facilities with an tion Cooldown OL or CP 80-14
. Radioactive Contamination of 6/24/80 All holders of power Plant Demineralized Water and research reactor System and Resultant Internal licenses (operating Contamination of Personnel and construction permits), and fuel cycle licensees 80-13 Grid Strap Damage in 5/18/80 All holders of reactor Westinghouse Fuel Assemblies OLs and cps-80-12 Valve-Shaft-To-Actuator Key 5/14/80 All: holders of reactor May Fall Out of Place When OLs and' cps Mounted Below Horizontal Axis l
L