Text

.

',,m

~) Comm._. wealth Edison (c_

(' O 7 z

One First:;nstional Plaz9, ChicTgo. Illinois,

'q,/

Addr:ss Reply t;: Post Offica Box 767

, Chic;go, Illinois 60690 Dresden Nuclear Power Station R. R. #1 Morris, Illinois 60450 22, 1975.__ W August ESS Ltr# 504-75

.J.

' ~ ~"' 0h 9

m' S. -

_ ' ' 'J.. I h, V--

J. Keppler, Regional Director Office of Inspection and Enforcement 3

l Region III C- '_

3L

[/

U.S. Nuclear Regulatory Cc:::::ission I--

. a..

.M 7 7og Roosevelt Road

-y Glen Ellyn, Ill 60137

SUBJECT:

Dresden Nuclear Power Station Semi-Annual Report N.R.C.

Dockets 50-10, 50-237, and 50-249

Dear Mr. Keppler:

Attached is the second portion of the Semi-Annual Report pertain-ing to Radioactive Effluent Discharges, Environmental Monitoring, Solid Radioactive 'Jaste, and Perconnel Exposures for Dresden Units 1, 2, and 3 for the period a t January 1,1975 tiuough June 30, 1975, as required by the Technical b.. cifications. Tne first portion of this report was trans-mitted under a separate cover.

One copy of this report is provided for your use, and 39 copies are being tranc=itted by this letter to Mr. Senard C. Rusche, Director of the Office of Nuclear Reactor Regulation.

Sincerely, b

% 3. B. Stephenson Station Superintendent EES:DA:Jea m

N10109fk

F 8/20/75 REVISED TABLE 1.2-2 REPORT OF RADIOACTIVE EFFLUENTS Docket No. 50-237'& 50-249 FACILITY: Dresden Unit 2 & 3 YEAR: 1975 Six Mg:H 1.2 Liquid Effluents Units Jan.

Feb.

March April' May June Total" 1.

Gross Radioactivity a)

Total Release Curies None 2.0E-02 8.9E-02 7 0E-02 2.3E-01 1.4E-01

$.$E-01 b) Average Concentration Released-pCi/ml None 2.6E-09 1.1E-98 1.1E-09 2.6E-09 5.9E-09 4.6E-09 c) Maximum Concentration Released pCi/ml None 3.4E-08 4.5E-08 2.3E-08 5.9E-08 6.6E-08 6.6E-08 d)

% of Tech Spec Limit None 2.61 10.5 1.1 2.59 59 4.6,

2.

Tritium a) Total Release Curies None 2.16E-04 5.29E-04 4.42E-03 2.51E+01 1.89E+01 4.4E+01 b) Average Concentration Released

.pCi/ml None 2.83E-11 6.26E-11 6.76E-11 2.84E-07 7.6E-07 2.1E-l 3.

Dissolved Noble Cases a) Total Release Curies b)

Average Concentration None Detected Released pCi/ml 4.

Gross Alpha Radioactivity

)

a) Total Release Curies None 1.63E-05 3.34E-05 2.50E-04 3.08E-02 4.88E-03 3.6E-02 i

b) Average Concentration Released pC1/ml None 2.1'E-12 3.95E-12 3.82E-12 3.49E-10 2.00E-10 1.1E-10 ;

1 8/20/75 REVISED TABLE 1.2-2 (Cont'd)

REPORT OF RADIOACTIVE EFFLUENTS Docket No. 50-237 6 50-249 YEAR

  • 1975 FACILITY:

Dresden Unit 2 & 3 Six Month 1.2 Liquid Effluents Units _

Jan.

Feb.

March April May June __

Total l

-:I" 5.

Volume of Liquid Waste to Disc rge canal Liters None 1.66E+05 6.47E-05 1.05E06 4.48E06 3.38E06 9.73E06 6.

Volume of Dilution Water Liters 8.45EO9 7.63E09 8.45E09 6'.54E10 9.0E+10 2.5E+10 2.0E11 7.

Isotopes Released Curies 1.4E-02 8.5E-03 2.8E-02 cs-134 None 2.3E-04 6.OE-03 Cs-137 None 4.7E-04 1.3E-02 6.9E-03 2.OE-02 1.5E-02 I-131 None 1.2E-03 1.4E-02 1.5E-02 9.6E-03 3.3E-02 None 2.6E-03 5 3E-03 Mn-s4 co-60 None 1.5E-02 4.5E-02 5.2E-02 6.3E-02 3.9E-02 2.1E-OL Sr-89 None 1.0E-05 4.9E-03 9.9E-03 1.3E-01 8.4E-02 2.3E-01 Sr-90 None 1.0E-05 2.0E-04 1.0E-03 4.1E-03 2.6E-03 7.8E-03 6.5E-04 None 6.5E-04 Ag-gow O

=

0

l.._...

(:.

o NRC DISTRIBUTION FOR PART 50 DOClkET MATERIAL (TEMPOR ARY FORM) 9181 CONTROL NO:

FILE: Fnvira c

F ROM:Connonwealth Edison Co.

DATE OF DOC DATE REC'D LTR TWX RPT OTHER Chicago, Illinbis XX B.B. Stenhenann A 99_74 n_90 7c TO:

~

O'RlG

'C C UTHER DENT NRC PDR

~

XX J. Ketspier 1-signed SENT LOCAL PDR XX CLASS UNCLASS PROP!NFO INPUT NO CYS REC'D DOCKET NO:

h0 50-237, and 50-249 x xxx DESCRIPTION:

ENCLOSURES:

Ltr trans the following*.

RaMoacthe Waste, Envhomental Monitoring and Occupational Personnel Radiation Exposure ACRS-1 January Through June, 1975 Dzpt of Interior-2 EPA-2

( 40 cys enc'1 rec'd)

Cys sent to Enviro Lic Asst for Dist k,n,, h

--,u..

n _-.._ J v.

PLANT NAME:

Dresden 1 thru 3 AM 8-29-75 JGB FOR ACTION /INFORMATION BUTLER (L)

SCHWENCER (L) ZIEMANN (L)

REG AN (E)

REID(L)

W/ Copies W/ Copies W/ Copies W/ Copict W/ COPIES CLARK (L)

STOLZ (L)

DICKER (E)

LE AR (L)

W/ Copies W/ Copies W/ Copies W/ Copies PAR R (L)

VASSALLO (L)

KNIGHTON (E)

SPIES V/ Copies W/ Copies W/ Copies W/ Copics j(OUNGBLOOD (E)

KNIEL (L)

PURPLE (L)

LPu W/ Copies W/ Copies W/ Copies W/ Copies A

INTERNAL DISTRIBUTION Mc o c 3 TECH REVIEW DENTON LIC ASST A/T IND.

M4HC PDR SCHROEDER GRIMES v6. DIGGS (L)

BRAITMAN OGC, ROOM P-506A MACCARY AMMILL H. GEARIN (L)

SALTZMAN GOSSICK/ STAFF KNIGHT STNER E. GOULBOURNE (L)

MELTZ CASE PAWLICKl ALLARD P. KREUTZER (E)

GIAMBUSSO SHAO SPANGLER J. LEE (L)

PLANS BOYD STELLO M. RU33DR00RL)

MCDONALD MOORE (L)

HOUSTON

_ ENVIRO S. REED (E)

CHAPMAN DEYOUNG (L)

NOVAK MULLER M. SERVICE (L)

DUBE (Ltr)

SKOVHOLT (L)

ROSS DICKER S. SHEPPARD (L)

E. COUPE GOLLER (L) (Ltr)

IPPOLITO KNIGHTON M. SLATER (E)

PETERSON P. CO L LINS TgDESCO YOUNGBLOOD H. SMITH (L)

HARTFIELD (2)

DEylSE

4. COLLINS DEGAN 5 TEETS (L)

KLECKER yG OPR LAIN AS

/ PROJECT,LD R

. WILLI AMS (E)

EISENHUT FILE & REGION (2)

BENAROYA R.jedLC V. WILSON (L)

WIGGINTON li1FC VOLLMER

' HAM LESS R. INGRAM (L) 5

!!. DUl:CAN (El p

EXTERN AL DISTRIBUTION M LOCALPDR Morris Ill

/ TIC (ABERNATHY) Ld, )(E7tt07-NATIONAL LABS MI _

1 - PD R. SAN /LA/NY f NSIC (BUCHANAN) 1 - W. PENNINGTON, Rm E.201 GT 1 - BROOKHAVEN NAT LAB 1-ASLB 1 - CONSU LTANTS 1 - G. ULSIKSON ORNL 1 -- Newton Anderson NEWM ARK /BLUME/AGBABI AN

- ACRS HOLDING /SENT i