ML19338E293

From kanterella
Jump to navigation Jump to search

Informs of Acceptability of Response to NRC Re Portions of ECCS Evaluation Models Dealing W/Fuel Cladding Swelling & Incidence of Rupture
ML19338E293
Person / Time
Site: Hatch 
Issue date: 09/09/1980
From: Reid R
Office of Nuclear Reactor Regulation
To: Widner W
GEORGIA POWER CO.
References
TAC-12731, NUDOCS 8009250421
Download: ML19338E293 (2)


Text

- - - - - - _ - _

(,F

]gg$

,p* **%

. o,',

- UNITED STATES NUCLEAR REGULATORY COMMISSION e

)

{'

s WASHINGTON,0. C. 20555

%, +..../

SEPTEliBER 9 1980 Docket No. 50-321 Mr. William A. Widner Vice President - Engineering Georgia Power Company P. O. Box 4545

. Atlanta, Georgia 30302

Dear Mr. Widner:

We have reviewed your response to our November 9,1979 letter concerning those portions of your ECCS evaluation models, dealing with fuel cladding swelling and incidence of rupture.

We find that you have adequately confirmed the representations made in your behalf by your fuel supplier.

We, therefore, conclude that your response is acceptacle and tnat no further action is necessary at this time.

Sincerely,

,.,t ; l 4 - /

l.

5L'-':'

Robert W. Reid, Chief Operating Reactors Branch #4 Division of Licensing cc: See next page 8009250 @l

w E

Hatch 1/2 If d'

(

50-321/366 '

Georgia-Power Company cc w/ enclosure (s):

G. F. Trowbridge, Esq.

Director, Technical Assessment Shaw, Pittman, Potts and Trowbridge Division 1800 M Street, N.W.

Office of Radiatien Programs Washington, D. C.

20036 (AW-459)

U. S. Environmental Protection Agency Ruble A. Thomas Crystal Mall #2 Vice President Arlington, Virginia 20460 P. O. Box 2625 Southern Services, Inc.

Birmingham, Alabama 35202 Ozen Batum Charles H. Badger P. O. Box 2625 Office of Planning and Budget Southern Service:. Inc.

Roon 610 birminghai, Mace na 35cu.

270 Washington Street, 3.W.

Atlanta, Georgia 303 %

Mr. H. B. Lee, Chairman Appling County Commissioners County Courthouse Baxley, Georgia 31513 Mr. L. T. Gucwa Georgia Power Company Engineering Department P. O. Box 4545 Atlanta, Georgia 30302 Mr. Max Manry Georgia Power Company Edwin I. Hatch Plant P. O. Box 442 Baxley, Georgia 31513 U. S. Environmental Protection Agency Region IV Office ATTN:

EIS COORDINATOR 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Appling County Public Library Parker Street Baxley, Georgia 31513 Mr. R. F. Rodgers U.S. Nuclear Reculatory Commission Route 1, P. O. Box 279 Baxley, Georgia 31513 b