September 12, 1980 Docket No. 50-412 Duquesne Light Company ATTN:
Mr. E. J. Woolever Vice President 435 Sixth Avenue Pittsburgh, Pennsylvania 15219 Gentlemen:
The enclosed IE Information Notice No. 80-32, " Clarification of Certain l
l Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this l
office.
Sincerely, l
oyce H. Grier j
Director l
Enclosures:
l 1.
IE Information Notice No. 80-32 2.
List of Recently Issued IE Information Notices l
l CONTACT:
H. W. Crocker l
(215-337-5217) l l
l cc w/encls:
l R. J. Washabaugh, Quality Assurance Manager l
h 341 8009240
SSINS: 6370 Accession No.:
8006190044
/
IN 80-32 f
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 August 29, 1980 IE Information Notice No. 80-32:
CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADI0 ACTIVE MATERIALS
\\
===.
Background===
In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.
In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.
IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.
During the past year, this augmented inspectio.n/ enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.
These questions involva mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.
The purpose of this Notice is to discuss the questions and clarify the applicability of certain requirements.
Aonlication of 49 CFR 173.393(i) and (i)
Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).
As stated therein, the regulation reads (j)
Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the li.its specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).
Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.
Such instructior.s must be included with the shipping paper information:
(1) 1,000 millirem per the package (closed DUPLICATE DOCUMENT (2) 200 millirem per ho the car or vehicle Entire document previously entered into system under:
l ANO Sobu 3 00%
No.'of pagec:
3 l
4'J CFil 173.303(jl-10 marm/lir 19 CFR 173.3031)).10 orzm/lir 2 mum /lir AT ATJY POINT 2 m (G f al
' 2 mee.n/li AT ANY l'OltJT 2 m (G lt)
FilOM Tile VERTICAL PLANES Pl10JECTED'
!~
FilOM Tile VEllTICAL PLAN 7 PflOJECTED FilOM Tile OUTEll EDGES OF VElllCLE.
e 11Y Tile OUTER LATEllAl. SURFACE l 2 miem/hr IN Call.
OF Tile Call On VElllCLE. 200 meem/hr I
y\\ h,.
AT ANY PoltJT ON Tile EXTERNAlf~
49 CFR 173.393(ll-200 mram/hr
- t. fpt
(
e SullFACE OF Tile CAR Oil d
- 's ON Tile EXTEnfJAL SullFACE OF p'
9
%gt - g' 9
Tile PACKAGE.10 mram/hr ~~
f 4@
9@9 l)
J VElllCLE.1000 mrem /hr AT 3 f a FROM Tile EXTERNAL 0
- N AT 3 f t FilOM ANY I
0 SullFACE OF Tile 9
ACCESSillLE EXTERNAL
/
p C
d, PACKAGE. 2 miem/hr e
g g
-SUIIFACE OF Tile PACKAGE.
1
~;
q Is. J,
(
I J,
l's IN CA D. ~ ~ --~ '
r g
r
\\
/6 V
,+l 200 s
e q
'y'
\\
s v
v
/*
k j
p/
c' y
\\p/,
c l /Dg c
,\\
/
f40TE: 200 mrom/hr e
/
70 T
. LIMIT ALSO APPLIES g
g 4',,'gsk s
AT UNDERSIDE OF y
VElllCLE.
EXCLUSIV.E-USE _ CLOSED TRANSPORT, EXCLUSlyE-USE OPEN TRANSPORT 49 CFR 173.393(il-200 mrem /hr
! AT ANY POINT ON Tile EXTERNAL.
APPF.NDIX A
\\@
, SURFACE OF Tile PACKAGE.
@S 110 n rrm/hr AT 3 f t FROM ANY' IE INF0lVMTION NOTICE g} 32
' ACCESSIDLE EXTEllNAL
{
.SUllFACE OF Tile PACKAGE.
t
~
+# /o4<,
1
/ c c=s>
RADIATION :
Ee
.' LIMITS c
/ "- v ha Wd
- l e
NOTE:
4 TOTAL Tl IS NOT NOTE:
P TO EXCEED S0 PER 1
. STOWAGE OF ACKAGES 49 CFR 173.393(i) AND.(j) 49 (Til 177.042(a),
(
WITillN VElllCL': MUST COMPLY WITil 49 CFil 177.842(bl, NON-EXCLUS!VE-USE OPEN OR CLOSED K
APPENDIX B IE INFORP% TION NOTICE M 32' WHAT COMPRISES THE PACKAGE 7 t,
40 CFR 171.Tl DEFINES PACK AGING SUCil TilAT YOU MUST CONSIDER Ti1E l.. ASSEMBLY OF ONE OR MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSAI1Y TO ACillEVE COMPLIANCE WITil Tile MINIMUM PACKAGING REQUIREMENTS..::
THEREFORE:
' INNER ASSEMBLY' OUTER ENCLOSURE ENTIRE OUTER IS PACKAGE" ~
IS A PERSONNEL ASSEMBLY is ENCLOSURE
^
HARRIER OR SIMULATED
- PAC K AG E" IS A SillELD
" CLOSED VElllCLE" h on M g%
l
-fg' gN fg'
' IN Tills SCENARIO, Tile INNER
!!N Tills SCENARIO, Tile M
PACKAGINGS MAY llE CONSIDERED ENTIRE ASSEMBLY (OUTER SHIELD g
i TO DE Tile " PACKAGE", PROVIDED PLUS INNER PACKAGINGS) MUST t
Tile OUTER ENCLOSURE IS NOT DE CONSIDERED AS Tile " PACKAGE",
e NECESSARY TO AClllEVE COMPLIANCE
' SINCE Tile OUTER SillELD IS M
I WITil Tile RADIATION LEVEL LIMIT NECESSARY TO AcillEVE COMPLIANCE
, OF 173.393(i)(2);i.e.,200 miem/hr, I WITil 173.393(ll(2). R ADIATION
.6 P>
LEVEL OF R ADIATION ON EACllINNER I LEVEL AT SURFACE OF " INNER" g
PACKAGE"MAY NOT EXCEED 1 rem /hr AT) l PACKAGINGS IS NOT LIMITED.
3' 3 f t FilOM ITS SU_RFACE..
Q)
~ " ~ ~
M W
j r'
i
IE Information Notice No. 80-32 September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.
Issued 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-DON 600S OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interaction a BWR power reactor Between the Control OL or CP Rod Drive Scram Function and ;<on-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/ 13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories
>