ML19338E018

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-32, Clarification of Certain Requirements for Exclusive-Use Shipments of Radioactive Matls. No Written Response Required
ML19338E018
Person / Time
Site: Seabrook  
Issue date: 09/12/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Tallman W
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
References
NUDOCS 8009240332
Download: ML19338E018 (1)


Text

7 TTX-

/[s,e jo,,

UNITED STATES E3 o

NUCLEAR REGULATORY COMMISSION 3 (*

j REG lON l 4

631 PARK AVENUE

%,..... 8 KING OF PRUSSIA, PENNSYLVANI A 19406 September 12, 1980 Docket Nos. 50-443 50-444 Public Service Company of New Hampshire ATIN:

Mr. W. C. Tallman Chairman and Chief Executive Officer 1000 Elm Street Manchester, New Hampshire 03105 Gentlemen:

The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, oyce H. Grier Director

Enclosures:

1.

IE Information Notice No. 80-32 2.

List of Recently Issued IE Information Notices CONTACT:

H. W. Crocker (215-337-5217) cc w/encls:

John DeVincentis, Projset Manager 8000240 3 3 2.

j

SSINS: 6370 Accession No.:

/

8006190044 f

IN 80-32 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 29, 1980 l

IE Information Notice No. 80-32:

CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADI0 ACTIVE MATERIALS

\\

===.

Background===

In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.

In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.

IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, i

1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.

During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.

These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.

The purpose of this Notice is to discuss the questions and clarify the applichbility of certain requirements.

Aeolication of 49 CFR 173.393(i) and d)

Numerous questions involve the application of the limits of adiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).

As stated therein, the regulation reads (j)

Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).

Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.

Such instructions must be included with the shipping paper information:

(1) 1,000 millirem per the package (closed DUPLICATE DOCUMENT (2) 200 millirem per ho the car or vehicle Entire document previously entered into system under:

ANO DNSNN No. of pages:

M

411 CFil 173.303(11-10 mr:m/hr 19 CFil 173.393(l)-10 mazm/hr 2 mpm/hr AT AfJY POltJT 2 m (G f t)

'2

'd I

AT ANY POINT 2 m (G lt)

FilOM Tile VEllTICAL PLANES Pi1OJECTED I'

FilOM Tile VEllTICAL PLANE PilOJECTED,

FilOM Tile OUTEll EDGES OI: VElllCLE.

11Y Tile OUTEll LATEllAL SUTIFACE l 2 miem/hr IN Call.

~

OF Tile Call OH VElllCl.E. 2(,9 mrem /hr I

s

/

AT ANY PolNT ON Tile EX1'E!1NAlf-49 CFil 173.303(il-200 mrem /hr d

(N ON Tile EXTEllfJAL SUf1 FACE OF SullFACE OF Tile Call Oil _

pI

(

Tile PACKAGE.10 mrom/hr. '

gS b

VElllCLE.1000 mrem /hr g-go 3g.

N

[f;S-f(

CESS ILE EX EIINAL

/ [

I i F LE O Tile 90 p

i PACKAGE. 2 mrem /hr th SullFACE OF Tile PACKAGE.

N 1

9

.hy 7

L k

~ - - ~ '

~

%r l

'@js*

I

/*

IN CAD.

a n

s N

msan /hr.

1 V

4.

y

\\

.,%N7

/

'y' I

t v

/

/ 4 l

\\

Y'

/

3/

r(

,s'#

\\

\\3V' r( l,A*',

/f

/

/

NOTE: 200 mrem /hr 8 I

g LIMIT ALSO APPLIES

  1. g

}

N AT UNDERSIDE OF

-% s k y

VElllCLE.

EXCLUSIVE-USE CLOSED TRANSPORT, EXCLUSNE-USE OPEN TRANSPORT 49 Cril 173.393(il 200 mrem /hr AT ANY POINT ON Tile EXTETINAL.

APPENDIX A Suf1 FACE OF Tile PACKAGE.

[

II0 n rrm/hr AT3 f t FilOM ANY M

IE IflFORfMTION tl0TICE 8) 32 g

ACCESSlHLE EXTEHNAL

'.Sul4 FACE OF Tile d

l y

rACKAGE.

ps

+# 4 C'

' p

--g 1

RADIATION :

v.

c L.>

/

"n

! LIMITS 2

,po - a" m-NOTE:

4r TOTAL Tl IS NOT NOTE:

TO EXCEED 50 PErl 1

. STOWAGE OF PACKAGES 49 CFR 173.393(i) AND.'(j)

Fr==-

49 i'F fl 177.042(a).

(

WITillfJ VElllCLE MUST COMPLY WITil 40 CI'll 177.842(h),

NON-EXCLUSIVE _USE OPEN OR CLOSED

I APPENDIX B IE INFORfMTION f0TICE F 2 o

WHAT COMPRISES THE PACKAGE 7 49 CFR 171.fl DEFINES PACK AGING SUCll TilAT YOU MUST CONSIDER Tite

".. ASSEMill.Y OF ONE OR MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSARY TO ACillEVE COMPLIANCE WITil Tile MINIMUM PACKAGING R E QUlH EM ENTS.."

THEREFORE:

'INNEh ASSEMDLY' OUTER ENCLOSullE ENTIRE OUTER IS " PACKAGE" IS A PERSONNEL ASSEMBLY IS

/ ENCLOSURE

~

'~'

UARRIER On SIMULATED

" PACKAGE"

/ IS A SillELD

" CLOSED VElllCLE"

% on M

/g

&N

/g

/

IN Tills SCENARIO, Tile INNER 8,1N Tills SCENARIO, Tile PACKAGINGS MAY BE CONSIDEllED ENTIRE ASSEMBLY (OUTER SillELD O

TO DE Tile " PACK AGE", PROVIDED PLUS INNER PACKAGINGS) MUST 9

Tile OUTER ENCLOSURE IS NDT e

DE CONSIDERED AS Tile " PACKAGE".

g NECESSARY TO AClllEVE COMPLIANCE SINCE Tile OUTER SillELD IS WITil Tile RADI ATION LEVEL LIMIT I

NECESSARY TO AcillEVE COMPLIANCE e_-,g

, OF 173.393(j)(2);l.a.,200 mrem /hr, IWITil 173.393(j)(2). R ADIATION LEVEL OF R ADIATION ON EACil INNER l LEVEL ATSullFACE OF "lNNER"

" PACKAGE"MAY NOT EXCEED 1 sem/hr ATI l PACKAGINGS IS NOT LIMITED.

3 f. t FR_ OM ITS SUR.F_A. C._E..

g W

b

a IE Information Notice No. 80-32

, - September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.

Issued

(

80 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-DON 600S-OL or CP Circuit Breakers 80-30 Potential for Unaccept- '8/27/80 All holders of able Interaction.

a BWR power reactor Between the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06' Significant Events power reactor OL at Operating Power and near term OL Reactor-Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories

_ - - - -