[ZL l "pe_ nerug'o,,

UNITED STATES

!^

j NUCLEAR REGULATORY COMMISSION a

REGION I

,d,.f 8,

631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19406 September 12, 1980 Docket No. 50-293 Boston Edison Company M/C Nuclear ATTN:

Mr. G. Carl Andognini, Manager Nuclear Operations Department 800 Boylston Street Boston, Massachusetts 02199 Gentlemen:

The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Matcrials," is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, oyce H. Grier Director

Enclosures:

1.

IE Information Notice No. 80-32 2.

List of Recently Issued IE Information Notices CONTACT:

H. W. Crocker (215-337-5217) cc w/encls:

P. J. McGuire, Pilgrim Station Manager

..800924o3 6

SSINS: 6370 Accession No.:

8006?.90044 f

IN 80-32 1

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 29, 1980 IE Information Notice No. 80-32:

CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADI.0 ACTIVE MATERIALS i

Backcround In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.

In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.

IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of i

Radioactive Material," issued September 7, 1979, provide background in this regard.

During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.

These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive

. wastes.

The purpose of this Notice is to discuss the cuestions ant! clarify the applicability of certain requirements.

Acolication of 49 CFR 173.393(i) and (D, Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).

As stated therein, the regulation reads (j)

Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).

Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.

Such instructions must be included with the shipping paper information:

(1) 1,000 millirem pt:r hour at 3 feet from the external surface of the package (close (2) 200 millirem per h DUPLICATE DOCUMENT the car or vehicle Entire docurcent previously entered into system under:

DUD ANO N o. of Pages:

S

49 CFil 173.303(ll.10 mr:m/hr 19 CFil 173.303(1) 10 mezm/hr 2 mrrm/hr AT ANY POINT 2 r3 (G 11)

'2 4

AT ANY I OINT 2 m (G It)

FilOM Tile VEllTICAL PLANES PilOJECTED'

~ FilOM Tile VEllTICAL PLANE PflOJECTEO -

I' l FilOM Tile OUTEll EDGES OF VElilCLE ilY Tile OUTEll LATEllAL SUilFACE

. ' ~

OF Tile Call OR VElllCLE. 200 mrem /hr l 2 smem/hr IN CAD.

AT ANY P8 titJT ON Tile EXTEllNALF' 49 CFil 173.393(i) 200 mram/hr A

e M g*eD Ota Tile E)(TEllNAL SURFACE 0,F L

SullFACE OF Tile Call Oil g@pl g

0 W

[

Tile PACK AGE.10 mrem /hr /

(

VElllCLE.1000 mrem /hr 9

N f(

9' p@

q @ c,g

-SullFACE OF Tile PACKAGE.

A p

p l RF CE O TifE gsO CESS LE EXT IlNAL

/

p PACKAGE. 2 mrem /hr g

p k h, p

i IN CAD.

b

' ~ " ~ ~ ~ ~

(

', D l

N s

200 N

m' ram /hr.

jgs*

,f A

1 6

y

\\

/

)

/

y*r/

i

'y' I

i 1

v pt l

\\

/

/

g l

6 /

(

, /q &'

\\

/

f l

I

/

A[ I

/

/

{

/

/

NOTE: 200 mrom/hr 8

/l

/

g fx 0,,?

{

LIMIT ALSO APPLIES i

s AT UNDEllSIDE OF g Nk y

VElllCLE.

EXCLUSIVE-USE CLOSED TRANSPORT, EXCLUSIVE-USE OP.EN. TRANSPORT 49 CFil 173.393(il 200 mrem /hr AT ANY PolNT ON Tile EXTERNAL.

APPENDIX A

,SUllFACE OF Tile PACKAGE.

i i10 c rem /hr AT 3 It FnOM ANY.

],

IE INFORt% TION NOTICE $32 gg

'ACCESSlHLE EXTERNAL

/

l (Q

.SUllFACE OF Tile PACKAGE.

pt l

- {g 6'4, P

i RADIATION :

2-1

/ '"

o.

.' LIMITS

@E s.

v

,00 v

i

t__,

NOTE:

4 TOTAL Tl IS NOT NOTE:

TO EXCEED 50 PER I

. STOWAGE OF PACKAGES 49 CFR 173.393(i) AND.'(j) 2D '

4fl rFil 177.042(a),

f WITillN VElllCLE MUST COMPLY WITil 40 CFil 177.042(bl, L

NON-EXCLUSIVE-USE OPEN OR CLOSED rnWGnnnr

'f APPENDIX B IE INFOR MTION NOTICE F 2 s

WHAT COMPRISES THE PACKAGE?

40 CFR 171.0 DEFINES PACKAGING SUCil TilAT YOU MUST CONSIDER Tile

.. ASSEM11LY OF ONE OR MORE CONTAINJRS AND ANY OTilER COMPONENTS NECESSARY TO AClllEVE COMPLIANCE WITil Tile MINIMUM PACKAGING REQUIREMENTS..*:

THEREFORE:

' INNER ASSEMBLY' OUTER ENCLOSURE ENTIRE OUTER IS A PERSONNEL ASSEMBLY IS ENCLOSURE IS" PACKAGE" ~

DARRIER OR SIMULATED

" PACK AGE" IS A StilELD

" CLOSED VElllCLE" 4

w on M

\\

~~

'gg%

  1. gg'

@@N

/@@

IN Tills SCENARIO, Tile INNER

'IN Tills SCENARIO, Tile PACKAGINGS MAY DE CONSIDERED ENTIRE ASSEMBLY (OUTER SillELD M

TO DE Tile " PACKAGE", PROVIDED PLUS INNFR PACKAGINGSI MUST Tile OUTER ENCLOSURE IS NOT DE CONSIDERED AS Tile " PACKAGE",

'Q i

NECESSARY TO ACillEVE COMPLIANCE SINCE Tile OUTER Sil: ELD IS WITil Tile RADIATION LEVEL LIMIT I

q NECESSARY TO AClllEVE COMPLIANCE N

. OF 173.393(j)(2);I.e. 200 mrem /hr, I

WITil 173.393(jl(21. RADIATION n

LEVEL OF R ADIATION ON EACil INNER l LEVEL ATSUllFACE OF "lNNER"

,q Er,

" PACKAGE"MAY NOT EXCEED 1 rem /hr AT) l PACKAGINGS IS NOT LIMITED.

3 it FilOM ITS SU.RFACE..

~~

cd8 c==3 N

IE Information Notice No. 80-32 September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES l

Information Subject Date Issued to Notice No.

Issued t

80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 ana K-DON 600S OL or CP Circuit Breakers 80-30 Potentia'i for Unaccept-8/27/t All holders of able Interaction-a BWR power reactor Between the Control OL or CP j

Rod Drive Scram Function and Non-essential Control Air ~at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of 1

Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/20 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A,-

II-D, III-I and IV-DI; Agreement State Licensees

'in equivalent categories

.=.

. _... ~,