ML19338D887

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 80-21, Regulation of Refueling Crews. No Written Response Required
ML19338D887
Person / Time
Site: Marble Hill
Issue date: 09/10/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Shields S
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
References
NUDOCS 8009240116
Download: ML19338D887 (1)


Text

/G ct:o

't UNITED STATES

.o E

3.f,([j NUCLEAR REGULATORY COMMISSION

!(

.: a REGION lli f[

799 ROOSEVELT ROAD S

o GLEN ELLYN, ILLINOIS 60137 SEF 10 S00 Docket No. 50-546 Docket No. 50-547 Public Service of Indiana ATTN:

Mr. S. W. Shields Senior Vice Presider

  • Nuclear Division Post Office Box 190 New Washington, IN 47162 Gentlemen:

The enclosed IE Circular No. 80-21 is forwarded to you for information.

No written response is required.

Should you have any questions related to your understanding of the recommendations on this matter, please contact this office.

Sincerely, O,m > lVdY" fJames G. Keppler Director

Enclosure:

IE Circular No. 80-21 cc w/ encl:

Mr. Steve J. Brewer, Nuclear TIC Safety and Licensing Supervisor LeBoeuf, Lamb, Leiby & MacRae Central Files Mr. Dave Martin, Office of the Director, NRR/DPM Attorney General Director, NRR/ DOR Mr. John R. Galloway, Staff PDR Director, Environment, Energy Local PDR and Natural Resources Subcommittee NSIC I

8009240116

'SSINS N2.:

6820-Accessicn No.:

8006190081

,k IEC 80-21 1*-

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF' INSPECTION AND ENFORCEMENT P

D 3

WASHINGTON, D.C. 20555 5

.u o 2

September 10, 1980 IE Circular No. 80-21:

REGULATION OF RtFUELING CREWS Description ~of Circumstances:

Recent inspections of refueling activities indicate that some licensees have misinterpreted the regulatory requirements applicable to fuel handling activi-ties. Therefore, it appears appropriate to identify those specific regulatory requirements that are applicable to core alterations which include reactivity manipulations.that may result. from the handlir9 of fuel elements, control rods, etc.

A.

10 CFR Requirements 1.

10 CFR 50.2(f) and 10 CFR 55.4:

" Controls" when used with respect to a nuclear reactor means apparatus and mtchanisms, t:1e manipulation of which directly affect the reactivity or power level of the reactor.

2.

10.CFR 50.54(i):

Except as provided in 55.9 of this chapter, the licensee shall not

-permit the manipulation of the coni-ols of any facility by anyone who is not a licensed operator or senior operator as provided in Part 55 of this chapter.

3.

10 CFR 55.3:

No person may perform the function of an operator as defined in this part except as authorized by a license issued by the Coinmission; 4.

10 CFR 55.4:

" Operator" is any individual who manipulates a control of a facility.

An individual is deemed to manipulate a control if he directs another to manipulate a control.

" Senior Operator" is any individual designated by a facility

(

licensee under Part 50 of this chapter to direct the licensed activities of' licensed operators.

5.

10 CFR 55.9:

Nothing in' this part shall be deemed to require a license for:

a.

An individual ~who manipulates the controls of a research or training reactor as part of his training as a student in a r ~

=

w.e-

IEC 80-21 Septembor' 10, 1980 Page 2 of-3

)

P nuclear _ engineering course under the direction and in the presence of a licensed operator or senior operator; b.

An individual who manipulates the controls of a facility as a part of his training to qualify for an operator license under this part under the direction and in the presence of.a licensed operator or senior-operator.

B.

Technical Specifications Standard Technical Specifications require that all core alterations be directly supervised by either a Licensed Senior Reactor Operator or a Senior Reactor Operator limited to fuel handling, who has no other con-current responsibilities during this operation.

The NRC interprets the term "directly supervised" to mean that the SR0 is supervising the core alterations from the refueling deck.

We note that the Licensed Senior Reactor Operacor limited to fuel handling classification was developed for specialized fuel handling crews.

In this case an individual identified as a Refueling Foreman is responsible for refueling activities subject to the following provisions:

1.

The foreman shall have a Senior Operator's License limited to the fuel bandling duties.

2.

The foremar shall directly supervise (from the refueling deck) the movement of fuel in and out of the reactor.

3.

The unlicensed members of the crew shall participate in appropriate facility administered training programs and be facility certified to perform their duties.

4.

Direct communication will be maintained with a licensed individual in the control room when fuel movements over the core are being made.

5.

The foreman will exerciso indirect supervision over all other fuel handling operations.

Based on the NRC regulations delineated in Item A above, the individual manipulating the fuel-handling equipment over the reactor must be an NRC Licensed Reactor Operator (RO) unless the facility Technical Specifications include provisions for the operation to be supervised by an SR0 or SRO limited i

to fuel-handling as described in-Item B.

During any core alteration, a licensed individual must also be observing reactivity monitors in the Control Room with appropriate communications established with personnel on the fuel handling equipment. -In addition, personnel participating directly in the core j

alternations must meet the qualification and training requirements committed to in the FSAR or fuel loading application, i.e., ANSI N18.1-1971 or ANSI /ANS 3.1-1978.

j

I-IEC 80-21

?

S:ptember 10, 1980 Pag 2 3 of 3

t Recommended Action for Licensee Consideration Our routine' inspection program for refueling activities is based on the above NRC requirements.

Therefore, we recommend that all reactor licensees review procedures and practices to assure that the individuals responsible for and participating in refueling activities are in conformance with the above requirements.

No' written response to this Circular is required.

If you require additional information with regard to this subject, please contact this office.

l i

l l

I i

l I

I i

I-i L

~

t*

IEC 80-21

[

Sept:mb;r 10, 1980

,1 RECENTLY ISSUED IE CIRCULARS Circular Date of No.

Subject Issue Issued to 20 Changes in Safe-Slab Tank 8/21/8C All Part 50 and Part Dimensions 70 fuel facility licensees 80-19 Noncompliance with 8/26/80 All medical licensees License Requirements for i

Medical Licensees 80-18 10 CFR 50.59 Safety 8/22/80 All power reactor Evaluations for Changes to facilities with an Radioactive Waste Treatment OL or CP Systems 80-17 Fuel Pin Damage Due to Water 7/23/80 All holders of PWR Jet from Baffle Plate Corner OLs and PWR cps 80-16 Operational Deficiencies In 6/27/80 All power reactor Rosemount Model 5100U Trip facilities with an Units And Model 1152 Pressure OL or a CP Transmitters l

80-15 Loss of Reactor Coolant Pump 6/20/80 All power reactor Cooling and Natural Circula-facilities with an tion Cooldown OL or CP l

l 80-14 Radioactive Contamination of 6/24/80 All holders of power Plant Demineralized Water and research reactor System'and Resultant Internal licenses (operating Contamination of Personnel and construction permits), and fuel cycle licensees 80-13 Grid Strap Damage in 5/18/80 All holders of reactor l

Westinghouse Fuel Assemblies OLs and cps 80-12 Valve-Shaft-To-Actuator Key 5/14/80 All holders of reactor May Fall Out of Place When OLs and cps Mounted Below Horizontal Axis 80-11 Emergency Diesel Generator 5/13/80 All holders of a power Lube Oil Cooler Foilures reactor OL or CP 80-10 Failure to Maintain-4/29/80 All ;,olders of reactor Environmental Qualification OLs and cps of Equipment i

i

_.