ML19338D588
| ML19338D588 | |
| Person / Time | |
|---|---|
| Site: | Vermont Yankee File:NorthStar Vermont Yankee icon.png |
| Issue date: | 08/29/1980 |
| From: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Rich Smith VERMONT YANKEE NUCLEAR POWER CORP. |
| References | |
| NUDOCS 8009230514 | |
| Download: ML19338D588 (1) | |
Text
YH
~%,
UNITED STATES
[E g
NUCLEAR REGULATORY COMMISSION i
j REGION 1 0,
g 631 PARK AVENUE 4
,d KING OF PRUSSIA, PENNSYl VANIA 19406 August 29, 1980 Docket No. 50-271 Vermont Yankee Nuclear Power Corporation ATTN:
Mr. Robert L. Smith Licensing Engineer 25 Research Drive Westborough, Massachusetts 01581 Gentlemen:
Enclosed is IE Bulletin No. 79-26, Revision 1, which requires action by you-with respect to your nuclear power facility (fes).
The original IE Bulletin No. 79-26 has been revised to adjust the required completion date for reporting the results of examination of an exposed control blade and to correct a typographical error.
The revision is identified by use of "R1" in the right margin.
In order to assist the NRC in evaluating the value/ impact of each Bulletin on licensees, it would be helpful if your would provide an ast..nate of the manpower expended in conduct of the review and preparation of the report (s) required by the Bulletin.
Please estimate separately the manpower associated with corrective actions following identification of problems through the Bulletin.
Should you have any questions regarding the Bulletin or actions required by you, please contact this office.
Sincerely,
=med?l, de f
yce H. Grier.
- ector
Enclosures:
1.
IE Bulletin No. 79-26, Revision 1 2.
List of Recently Issued IE Bulletins CONTACT:
D. L. Caphton (215-337-5266) 8009280514
Vermont Yankee Nuclear Power 2
-Corporation ccw/encls:
Mr. Warren P. Murphy, Plant Superintendent Mr. W. F. Conway, Vice President and Manager of Operations Mr. J. E. Griffin, President Mr. L. H. Heider, Vice President
.t =
SSINS No.: 6820 Accession No.:
UNITED STATES 8006190042 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 August 29, 1980 IE Bulletin No. 79-26 Rev. 1 BORON LOSS FROM BWR CONTROL BLADES Description of Circumstances:
The General Electric Company (GE) has informed us of a failure mode for control blades which can cause a loss of boron poison material.
Hot cell examinations of both foreign and domestic blades have revealed cracks near the upper end of stainless steel tubing and loss of boron from the tubes.
The cracks and boron loss have so far been ggnfined to locations in the poison tubes with more than 50 percent Boron-10 (B ) local depletion.
Observed crack sizes range fror a quarter to a half inch in length and from one to two mils in width.
GE has postulated that the cracking is due to stress corrosion induced by solidification of boron carbide (B C) particles and swelling of the compacted 3
B C as helium and lithium concentrHtions grow.
Once primary coolant penetrates 4tne cladding (i.e., the cracking has progressed through the cladding wall and thehelium-lithiumpressuresaresufficienttoopenthecrack),bgronis leached out of the tube at locations with more than 50 percent B local depletion (local depletion is considered to be twice the average depletion).
Itwasfurtherfoundwithsimilarcrackingbutwithlessthan50percentlocal 7
depletion of B
, that leaching did not occur even though primary coolant had penetrated the cladding.
i The cracking and boron loss shorten the design life of the control blade.
According to the GE criteria the end of design life is reached when the reactivitywggthofthebladeisreducedby10 percent,whichcorrespondsto 42 percent B depletionaveragedoverthetopquarterofthecontrolglade.
y Because of the leaching mechanism, GE has reduced the allowance for B deple-tion averaged over the top quarter of the control blade from the 42 percent value to 34 percent.
The safety significance of boron loss is its impact on shutdown capability and scram reactivity.
Although shutdown capability is demonstrated by shutdown margin tests after refueling, the calculated control blade worths used in the tests are based on the assumption that no boron loss has occurred.
Reduction in scram reactivity due to boron loss could increase the severity of Critical Pw
~
' ant transients and could increase ents.
DUPLICATE DCCUMENT Entire document previously entered into system under:
dh bb ANO No. of pages: