TENNESSEE V ALLEY AUTAC R PY t w nccci rwmtr r :.

1750 Chestnut Street Tower II September 2, 1980 Mr. James I. O'Reilly, Director U.S. huclear Regulatory Comission Office of Inspection and Enforcement Region II 101 ifarietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

TENNESSEE VALLEY AUTtIORITY - SEQUOYAli NUCLEAR PLANT UNIT 1 - DOCRET NO. 50-327 - TACILITY OPi. RATING LICENSE DPR REPORTABLE CCCURRENCE REPORT SQRO-50-327/53129 The enclosed report provides details concerning the failure of DG 1A-A to start during a simulated blackout test. This report is submitted in accordance with Sequoyah unit 1 Technical Specification 6.9.1.13.c.

Very truly yours, TENNESSEE VALLEY AUTHORITY J. R. calhnun Director of Nuclear Power Enclosure (3) cc (Enclosure):

Director (3)

Off*ca of Management Information and 'rogram Cont.rol U.a. Nuclear Regulatory Comission Washington, DC 20555 Director (40)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Comission Washington, DC 20555 Mr. Bill Lavallee Nuclear Safety Analysis Center 00 3 Palo Alto, California 94303 3

Mr. W. T. Cottle, NRC Inspector, Sequoyah j /

1 8009080&A S