9 NUCLE AR ENERGY BUSINESS GROUP e GENER AL E LECTRIC COMPANY SAN JOSE, CAltFORNI A 35125 GENER AL h ELECTRIC APPLICABLE TO:

NEDO-24082 PUB LIC GI N NO.

ERRATA And ADDENDA 77NED356 T.1. E. NO~

SHEET LOCA ANALYSIS FOR PEACH 2

TITLE BOTTOM ATOMIC POWER STAT [0N June 1980 DATE UNIT 3 NOW Conectallcopies of the applicable December 1977 1SSUE DATE publication as specified below.

REFERENCES INSTRUCTIONS ITEM (SECT ION, P AG E PAR AG R APH, LINE)

(CORRECTIONS AND ADDITIONS) 1 Page 3-1/3-2 Replace with new page 3-1/3-2.

2 Pages 4-9 and 4-10 Replace with new pages 4-9 and 4-10.

3 Page 4-11 Replace with new page 4-11.

4 Page 4-13 Add new page 4-13.

(Change bars in right-hand margin indicate areas where report has been revised.)

i PAGE I Of 1 0010020

.o NEDO-24082 3.

INPUT TO ANALYSIS A list of the significant plant input parameters to the LOCA analysis is presented in Table 3-1.

Table 3-1 SIGNIFICANT INPUT PARAMETERS TO THE LOSS-OF-COOLANT ACCIDENT ANALYSIS Plant Parameters:

Core Thermal Power 344) MWt, which corresponds to 105% of rated steam flow Vessel Steam Output 14.05 x 106 lbu/h, which corresponds to 105% of rated steam flow Vessel Steam Dome Pressure 1055 psia Recirculation Line Break Area for Large Breaks - Discharge 1.9 ft2 (DBA)

- Suction 4.1 ft2 (DBA)

Number of Drilled Bundles 432 Fuel Parameters:

Peak Technical Initial Specification Design Minimum Linear Heat Axial Critical Fuel Bundle Generation Rate Peaking Power l

Fuel Type

_ Geometry (kW/ft)

Factor Ratio

  • A.

IC Type 2 7x7 18.5 1.5 1.2 B.

IC Type 3 7x7 18.5 1.5 1.2 i

C.

8D274L 8x8 13.4 1.4 1.2 D.

8D274H 8x8 13.4 1.4 1.2 E.

PTA260 8x8 13.4 1.4 1.2 F.

8DRB283 8 x 8R 13.4 1.4 1.2 G.

P8DRB284H 8 x 8R 13.4 1.4 1.2

  • To account for the 2% uncertainty in bundle power required by Appendix K, the SCAT calculation is performed with an MCPR of 1.18 (i.e., 1.2 divided by 1.02) for a bundle with an initial MCPR of 1.20.

3-1/3-2

.o NEDO-24082 Table 4-3c MAPLilGR VERSUS AV.~. RAGE PLANAR EXPOSURE Plant:

PB-3 Fuel Type:

8D274L Average Planar Exposure MAPLllGR PCT 0xidation (Mwd /t)

(kW/ft)

(*F)

Fractian_

200 11.2 1728 0.005 11.3 1735 0.005 1,000 11.9 1814 0.007 5,000 12.1 1828 0.007 10,000 15,000 12.2 1852 0.008 20,000 12.1 1852 0.007 23,000 11.6 1815 0.006 10.9 1737 0.005 30,000 35,000 10.0 1631 0.003 40,000 9.3 1559 0.002 4-9

O NEDO-24082 Table 4-3d MAPLifGR VERSUS AVERAGE PLANAR EXPOSURE Plant:

PB-3 Fuel Type:

8D274H Average Planar Exposure

L\\PLliGR PCI 0xidation O!wd/t)

(kW/ft)

(*F)

Fraction 200 11.2 1722 0.005 1,000 11.2 1724 0.005 5,000 11.8 1799 0.006 10,000 12.1 1830 0.007 15,000 12.2 1853 0.008 20,000 12.1 1853 0.007 25,000 11.5 1808 0.006 30,000 10.9 1737 0.005 35,000 9,9 1631 0.003 40,000 9.3 1559 0.002 l

l l

l i

i 1

l l

4-10

o NEDO-24082 Table 4-3e MAPLilGR VERSUS AVERACE PLANAR EXPOSURE Plant:

PB-3 Fuel Type: PTA260 Average Planar Exposure MAPI.IIGR PCT 0xidation (Mwd /t)

(kW/ft)

(*F)

Fraction 200 11.4 1794 0.006 1,000 11.5 1803 0.007 5,000 12.1 1875 0.009 10,000 12.2 1891 0.009 15,000 12.3 1920 0.010 20,000 12.1 1923 0.010 25,000 11.7 1875 0.009 30,000 11.3 1847 0.008 35,000 10.3 1717 0.005 40,000 9.7 1645 0.003 4-11

NEDO-24082 Table 4-3f MAPLilGR VERSUS AVERAGE PLANAR EXPOSURE Plant: PB-3 Fuel Type:

8DRB283 Average Planar Exposure MAPLilGR PCT 0xidation (l tad / t)

(kil/f t)

(*F)

Fraction 200 11.3 1823 0.007 1,000 11.4 1822 0.007 5,000 11.9 1884 0.009 10,000 12.1 1902 0.009 15,000 12.1 1917 0.010 20,000 11.9 1903 0.010 25,000 11.3 1844 0.008 30,000 11.1 1815 0.007 4-12 l

l I

NED0-24082 Table 4-3g MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Plant:

PB-3 Fuel Type: P8DRB284H Average Planar Exposure MAPLHGR PCT Oxidation (mwd /t)

(kW/fd

('F)

Fraction 203 11.3 1812 0.007 1,000 11.3 1813 0.007 5,000 11.7 1858 0.008 10,000 12.1 1894 0.009 15,000 12.0 1897 0.009 20,000 11.6 1858 0.008 25,000 10.9 1777 0.006 30,000 10.2 1700 0.004 1

l i

4-13