_.

9 CAORSO SINGLE VALVE TESTS

  • EVALUATION OF PRESSURE DATA BASE
  • ACTUATION OF VALVE "A".

8 010 0 204b5

i a

i 4

PRESSURE TRACES RECORDED DURING CA0RSO SINGLE VALVE TESTS WERE GROUPED AS FOLLOWS:

o MULTIPLE FREQUEllCY PRESSURE (NFP) WAVE FORM TYPE o

SINGLE FREQUENCY PRESSURE (SFP) WAVE FORf1 TYPE i

l

e MFP WAVE FORM CHARACTERISTICS:

o RICH IN FREQUE' ICY CONTENT IN THE RANGE OF 15 Hz TO 40 Hz (FRONT END OF TRACES) o A DOMINANT SINGLE CHARACTERISTIC FREQUENCY IN THE RANGE OF 6 Hz TO 10 Hz (TAIL END OF TRACES).

o NEGLIGIBLE FREQUENCY C0flTENT IN THE RANGE > 40 Hz.

o RANDOM PROPERTIES:

PRESSURE AMPLITUDE AND FREQUENCY CONTENT.

SFP WAVE FORM CHARACTERISTICS:

o EXHIBITS PRIMARILY A SINGLE DOMINANT CHARACTERISTIC FREQUENCY IN THE RANGE OF 6 Hz TO 10 Hz.

o SMALLER CONTRIBUTIO.1 (THAN MFF'S) IN THE RANGE OF 15 Hz TO 40 Hz.

o NEGLIGIBLE FREQUENCY CONTENT IN THE RANGE > 40 Hz.

o RANDOM PROPERTIES:

PRESSURE AMPLITUDE AND FREQUENCY CONTENT.

CORRR ATION ANALYSIS OF RECORDED BOU.51DARY PRESSURES T'd0 TYPICAL TESTS WERE CONSIDERED:

o TEST 502 (MFP WAVE FORM TYPE), AND o

TEST 2202 (SF? WAVE FORM TYPE).

MATRIX OF CROSS-CORRELATION COEFFICIENTS F0P.

PRESSURE TRACES RECORDED BY SENSORS P 9, P13, P14, P11 AND P10 WAS CALCULATED.

RESULTS OBTAINED INDICATE NEAR PERFECT CORRELATION ONLY AT 17= 0.

CONCLUSIONS:

TEMPORAL BEHAVIOR IS INDEPENDENT OF SPATIAL DISTRIBUTION o

FOR MEASURED BOUNDARY PRESSURES, t.e.,

P(R,T) = PC,a)

  • T(T) 1 o

'dATtR IN SUPPRESSION POOL MAY BE ASSUMED AN INCOM-PRESSIBLE FLUID.

_