Text

c;,.,

i;;

<2.-

i s: t':

AMENDMENT to the i

MONTICELLO Effluent and Waste Disposal Sealannual Report

\\

(for the 2nd Half year of 1988)-

i This report-provides the previously omitted 2nd qucrter analyses results of Sr-89 and Sr-90.

4 R

y

=--

[

Pcge

'l p' ~-

<!MONTICELLDEMUCLEAR GENERATIMG PLANT-Periodt Jul - Dec'1988 cMORTHERN STATES. POWER COMPAXY License No. DPR-22 i

EFTLUENT AND=WASTELDISPOSAL SEMIAMXUAL REPORT 1

Supplemental-Infor'mation

+

11.. Regulatory Limits - Guarterly levels requiring reporting-to. Nuclear Regulatory Commission

-A.2Moble Gases u

N 5 mrad / quarter' gamma radiation 10 mrad / quarter beta radiation

~

^

B.--Long-Lived Iodines, Particulates, and Tritium 8 g

T7-.5_mram/ quarter to any-organ-

)

C.

Liquid Effluents -

1.51 mrem / quarter dose.to the total body 5.0 mram/ quarter dose to any organ

'2;-Maximum ~ Permissible Concentrations:

e A'.

Noble Gases-

'10 CTR-Part 20,. Appendix:B, Table II, Column'1'-

' B'.

Long - Live d' Iodines, Particulates, and Tritiuli 10;CTR.Part 20, Appendix B, TableEII,' Column't

- C.

Liquid Effluentsi 10 C FR.' P ar t E 2 0, Appendix.B, Table II, Column 2 2 E-04 uci/ml for dissolved and entrained gases E : 3 ', Average-Energy:

4 Hot, Applicable) s 9

l:/

l l..

.. - -.. ~.

~

5 POgo-2 MONTICELLO MUCLEAR GENERATING PLANT Period:

Jul - Dec 1988

~,MORTHERN STATES POWER COMPANY License No. DPR-22 s

EPTLUENT AND WASTE DISPOSAL SEMIAXNUAL REPORT Supplemental Information (continued) 4.

Maasurements and Approximations of Total Radioactivity A.

Moble Gasess Continuous gross activity monitors in Reactor Building Vent and plant stack exhaust streams.

Weekly. isotopic analysis of steam det air ejector streata.

Monthly analysis of storage tank contents.

A B.

Iodines in Gaseous Effluents Continuous monitoring with charcoal cartridges in Reactor Building n

Vent and plant stack exhaust streams with weekly analysis.

C.

Particulates in Gaseous Effluents Continuous monitoring with particulate filters in Reactor Building vent and plant stack exhaust streams with weekly analysis.

D.

Tritium in Gaseous Effluent Continuous monitoring with silica gel cartridges in Reactor Building vent and: plant stack exhaust streams with biweekly analysis.

E. Liquid Effluents:

Tank sample analy=ed prior to each planned release and continuous monitoring of gross activity during planned release.

$. Batch Releases:

t A.

Liquid:

1. Number of Batch Releases 0
2. Total Time Period For Batch Releases 0.0 Min 3.. Maximum Time Period for a Batch Release 0.0 Min 4.

Average Time Period for a Batch Release 0.0 Min

5. Minimum Time Period for a Batch Release 0.0 Min 6.

Average River Flow During Releases 0.0 Cf/sec

~B.

Gaseous

1. Number of Batch Releases 0
2. Total Time Period for Batch Releasec MA Min
3. Maximum Time Period for a Batch Release HA Min
4. Average Time Period for a Batch Release HA Min
5. Minimum-Time Period for a Batch Release NA Min 6.. Abnormal Releasest A.

Liquid 1.

Number of Releases 0

2.

Total Activity Released 0.0 Ci l

lB.

Gaseousi I

1.

Humber of Releases 0

2.

Total Activity Released 0.0 Ci

\\

%qv N

?h w.

t kN t i 15 Pcgo.3:

g MOMTICELLO-NUCLEAR GENERATING. PLANT Period Oh1 - Dec 1988 d.(; NORTHERN STATES POWER. COMPANY:

License No. DPR-22 4

pl:;N,3 IIPPLUEXT AND WASTE DISPOSAL SEMIANNUAL REPORT Table 1A Gaseous Effluents - Summation of all' Releases 1,

Units 1st Str-2nd Str Pont Est Error J

rg hC A.

Noble Gases-1.< Total Release:

i

'A.

Elevated Release C1 1.91E+03 1.74E+03

'B.

Building: Vent Release C1 2.63E+02 2.49E+02 LC. Total' Ci 2.17E+03 1.99E+03-5.00E401 12..AverageTRelease Rate:

"A.

Elevated Release uci/sec 2.40E+01 2.18E+0i T

B.

Building Vent Release-uCi/sec 3.30E+01 3.14E+01 C.

Total:

uC1/sec-2.73E+02 2.50Et02 5.00E+01

< 3.

Percent Tech Spec Strly Reporting Level Gamma Radiation 6.00E+00 5.86E+00-Beta Radiation 3.57E+00 3.55E+00 l.

~B.

Iodines 11.l Total I-131:

A.

Elevated Release C1 4.03E-03'3.18E-03 B,. Building Vent Release Ci 7.04E-03 6.35E-03 L

C.

Total C1 1.11E-02 9.52E-03 5.00E+01 2.-Average I-131 Release Rate 2

-~

A.

Elevated' Release uC1/sec 5.07E-04-4.00E-04 L

B.

Building Vent Release uC1/sec 8.86E-04 7.ver-u4 C.

Total uC1/sec 1.39E-03 1.20E-03 5.uSE+01 C.

Long Lived Particulates and Gross Alpha Releases i.-

_1. Total Particulates:

A.

Elevated Release C1 1.07E-03 3.16E-02 B.

Building Vent Release ci 6.72E-05 6.03E-04 p

C.

Total C1 1.13E-03 3.22E-02 5.00E+01 I

l~

2.: Average Release Rater

[

A.

Elevated Release uC1/sec 1.34E-04 3.98E-03 B.-Building Vent Release uC1/sec 8.45E-06 7.58E-05 C.

Total uCi/sec 1.43E-04 4.05E-03 5.00E+01

J j

p-n

- fen i

Pego 4

>~

t I'MONTICELLO NUCLEAR GENERATING < PLANT Periodt Jul - Dec 1988.

fj.UORTHERM.ST ATES 4 POWER COMPANY-License-No. DPR ITFLUENT AND.' WASTE DISPOSAL SEMIANNUAL REPORT ~

s t::

5 Table 1A' Gaseous Effluents - Summation of All Releases-(Continued) t

> Units 1st Str 2nd'Str Pont'Est-

________ ________ ________' Error i?

3.

Gross A1Pha. Radioactivity

.A.

Elevated: Release C1 1.71E-07 1.62E-07 lB.~ Building Vent Release Ci 9.46E-06-6.46E-06 C.

Total-C1 9.63E-06 6.62E-06 1.00E+02.

t 1D iTritiumi.

1.JTotal Releases

!A. Elevated Release C1 5.66E+00 3.73E+00 B.

Building Vent ~ Release C1 2.04E+01 2:12E+01 C.

Total CI 2.61E+01=2.50E+01 5.00E+01 2.-Average Relcase Rates

.A.

Elevated Release

-uci/sec 7.13E-01 4.69E-01

' B '. Building Vent. Release-uCi/sec 2.57E+00 2.67E+00 C.- Total uci/sec 3.28E+00 3.14E+00 5.00E+01

.E. Porcent Tech Spec 9triy Reporting 2.24E+00 1.96E+00-Lavel_for-Long Lived Iodines, Patriculates, and Tritium h

L 1 1 l

l'

~ __

g,y

.)

  • / v.i 3-

-t<

f Pogo:

5-mu

-k 50MTICELLO1HUCLEAR GENERATING PLANT Periods-Jul nDec~1988 f,HORTHERM STATES POWER COMPANY License No.-DPR-22:

i ci.-

EPPLUENT=AND' WASTE DISPOSAL SEMIAMMUAL REPORT Table IB-Gaseous Effluents - Elevated Release m

Continuous Mode.

Batch Mode

Nuclides Released Units 1st Str 2nd Str 1st Str-2nd Str

'i(1.lNoble Gasesi e,

Xo 13 3' HCi 5.67E+02 5.94E+02

-0.0 0 'O X

7 o135' C1 1.93E+01 1.62E+01

'0. 0 0.0

.Kr85M C1 4.04E+00 3.37E+00 0.0 0.0 1+Kr88 C1 1.31E+01 1.10E+01 0.0 0.0 4

.Kr87:

C1 2.01E+01 1.66E+01 0.0 0.0

- 'Xo138 Ci 3.34E+02 2.85E+02-0.0 0.0 Kr90 C1 1.17E+01 9.87E+00 0.0

.0.0 Xo139 C1 3.48E+01-2.94E+01 0.0 0.0-Kr89 C1 3.46E+02 2.92E+02 0.0 0.0 uXs 13 7 '

C1 4.52E+02 3.82E+02

0. 0' O.0 Xs135M' C1 2.69E+01 2.27E+01 0.0' O0

'Kr83M C1 4.41E+00 3.17E+00 0.0 0.0 Xe133M C1 2.07E+00 2.60E+00 0,0 0.0 Xe131M-C1 3.13E+00' 3.05E+00 0.0 0.0 Kr85' Ci 6.78E+01 6.54Ev01 0.0 0.0

. Total for Period C1 1.91E+03 1.74E+03 0.0 0.0

=2 Iodiness c

I-131^

C1 4.03E-03 3.18E-03 0.0 0.0 EI-133 C1 1.78E-02 1.36E-02 0.0 0.0 I-135-Ci 2.30E-02 1.91E-02 0.0 0.0 Total C1 4.48E-02 3.58E-02 0.0 0.0 4

c 1

i l

r p-

~.. f PC90- -6 (MONTICELLO MUCLEAR' GENERATING PLANT Period:

Jul - Dec 1988 License Mo'.

DPR-22 p.MORTHERM' STATES POWER-COMPANY.

EFFLUENT-AMD WASTE DISPOSAL-SIMIAMMUAL REPORT

Table IB Gaseous ~ Effluents - Elevated Release (Continued)

Continuous Mode Batch' Mode

_Muc i es ~ Released

' Units 1st Str 2nd Str 1st Str 2nd Str ld

'. 3-.

P a r t i c u l a t e s :

Ce141 Ci 0.0.

4.06E-07 0.0 0.0:

~Ba140 Ci 8.75E-04 3.07E-02 0.0 0.0 Cs137-Ci 3.73E-05 3.55E-04 0.0 0.0 Rul03 Ci 0.0 4.26E-07 0.0 0.0 Sr90

'Ci 7.51E-07 2.70E-06 0.0 0.0 Sr89 C1 1.54E-04 4.72E-04 0.0 o0. 0 Zn65 Ci 0.0 7.56E-07 u0.0-0.0

-Co60 Ci 0.0 9.94E-06 0.0 0.0-i Fe59 Ci 10. 0 -

4.75E-06 0.0 0.0 CoS8 Ci 0.0 8.59E-07 0.0 0.0 Mn54-C1 0.0 4.31E-06 0.0 0.0

~'

Cr51 C1 0.0 1.25E-05 0.0 0.0 Total C1 1.07E-03 3.16E-02 0.0 0.0 I

s

+

-.,.,,w

~

r

.,,s

-a

n;

!(.3 IPogc if

. MONTICELLO. XUCLE ARL GENER A TING'.PL AXT :

Period:

Ju1J Dec1988 LNORTHERN STATES ~ POWER COMPANY License.No. DPR-22 ITFLUENT AND WASTE DISPOSAL SEMIAMMUAL REPORT 4-4 Table'IC Gaseous Effluents - Building VenteRelease 0

Continuous Mode Batch Mode Nuclides Released' Units 1st Str 2nd Str 1st Str 2nd Str.

1.'MobleIGases RXo133J C1 5.63E-01 5.55E-01 0.0 0.0 XoI35 Ci 4.08E+00 3.85E+00 0.0 0.0

.;Kr85M Ci 8.44I-01 7.85E-01 0.0

0.0 'Mr88

C1 2.76E+00 2.58E+00 00 0.0

Er87, C1 4.19E+00 3.91E+00 0.0 0.0

'Xo138 C1 6.89E+01 6.60E+01 ~ 0. 0 0.0 Kr90 C1 2.41E+00 2.29E+00-0.0 0.0 Xs 13 9.

Ci 7.18E+00 6.81E+00 0.0 0.0 LKr89 Ci 7.16E+01 6.78E+01 0.0 0.0

.Xc137 Ci 9.36E+01 8.87E+01 0.0 0.0 Xe135M Ci 5.59E+00 5.27E+00 0.0 0.0 Kr83M C1 7.94E-01 7.42E-01 0.0 0.0

Xe'133M-C1 2.06E-02 1.98E-02 0.0 0.0 l

'Xo131M C1 1.13E-03 1.15E-03 0.0 0.0 Mr85 Ci 1.02E-02 1.17E-02 0.0 0.0 Total-for Period C1 2.63E+02 2.49E+02 0.0 0.0 1

1 2.

Iodiness I-131

'(%L 7.04E-03 6.35E-03 0.0 0.0 I-133 C1 4.13E-02 3.75E-02 0.0 0.0 I-135 Ci 6.77E-03 1.65E-02 0.0 0.0

. Total Ci 5.52E-02 6.03E-02

-0.0 0.0 i

i t

i

g; r-m...,

l

' 'y :-

F.

3%

Pogo 8

i}jw -

p

';MONTICELLO' NUCLEAR GENERATING PLANT' Period:

Jul - Dec 1988~

License No. DPR-22 (ROP.THERN. STATES POWER': COMPANY EFFLUENT AND WASTE' DISPOSAL SEMIANNUAL REPORT

,'e Table 1C' Gaseous Effluents - Building Vent 1 Releases (Continued)

Continuous Mode Batch Mode

'Mus11 des Released Units-1st Str 2nd Str 1st Str-2nd Str 3.'Porticulates L

Ac140 Ci 0.0 2.80E-04

-0.0 0.0

1. 0 2.21E-06 0.0' O.0 0

- Cs137; Ci Sr90 C1 4.16E-08 8.18E 0.0 0.0' Sr89 C1

-6.71E-05 1.15E-04 0.0

0. 0:

Co60-C1

-C.0' 1.62E-04 0.0

0. 0,

Mn54 C1 0.0 8.71E-06 0.0 0.- 0 o

Cr51 Ci 0.0 3.39E-05 0.0 0.0

~

- Total.

C1 6.72E-05 6.03E-04 0.0 0.0 3

I i

6 l

l I

1 i

I

((

.YV,

'm Pogo. 9 wy

?MONTICELLO=NUCLEARLGENERATING PLANT Period Jul - Dec-1988

,fMORTHERN STATES ~ POWER COMPANY-License No. DPR-22.l

p,.

Ei' EFTLUENTiAND WASTE DISPOSAL SEMIAXXUAL REPORT tib

~

Table 2A.-Liquid Effluents - Summation offA11 Releases Units 1st-Str 2nd 9tr' Pont Est Error A. T.ission and-Activation Products:

1.-' Total Release-Ci l0.0 0.0 0.0; 2

(Except H-3, Gases, and Alpha)

2.

Avg Diluted Concentration uCi/ml 0.0 0.0

-B.

Tritium

!n 6

1. Total Release Ci 0.0 0.0 0.0 l
2. Avg Diluted Concentration uC1/ml 0.0 0.0 C.. Dissolved:and Entrained Gases

!1'.

Total Release ci 0.0 o0. 0 0.0 l0.

Avg! Diluted Concentration uC1/ml 0.0 0.0 3

D.

Percent.Strly Tech Spec Reporting

level

, WholeL Body Dose 0.0

'0.0

(<

Organ. Dose' O.0 0.0 E. ~ Gross Alpha Radioactivity-1.. Total Release C1 0.0 0.0 0.0 T; Volume of Haste Released Liters 0.0 0.0 0.0 G.; Volume of Dilution Water Used Liters 0.0 0.0 0.0 i

L l

l

~

p.

.w; l Pogo - j o_-

3 L 1MONTICELLO.. NUCLE A R G ENERATING.:' PL ANT -

Periods: Jul Dec 1988

,... ;. NORTHERN STATES 5 POWER COMPANY-License No'.

DPR-22

_i i

. EPTLUENT AND WASTE DISPOSAL _ SEMIANNUAL. REPORT T a b l e 12 8.-

Liquid Effluents continuous Mode Batch Mode Nuclides Released-Units 1st-Str 2nd Str 1st Str 2nd Str Mone Released This Period-4

{

t s

I Y e

4 l

}*-? 7

>Tt

's.

y

~,.

m Pcgo 11

!MS I !

4 IMONTICELLO'XUCLEAR GENERATING PLANT-s RJ(NORTHERM STATES (POWER COMPANY'

- Periodt Jul-- Dec 1988

~

- License-No. DPR-22

' I s.4 I

ETTLUENT AMD. WASTE' DISPOSAL SEMIAMMUAL REPORT Table 3 Solid Waste and.. Irradiated Tual Shipments

.Al) Solid! Waste Shipped.0ffsite For Burial'or. Disposal:

o;:

- 1.,Typeiof' Wastes

+.

Pent Est=

Units-Total-LError

'A; Spent. Resins, Tilter Sludges, Cu Meter 2.33E+01 nIvaporator Bottoms,'Itc.

Ci 8.54E+01.5.00E+01~

-B.

Dry compressible Waste, Cu Meter 3.75E+01'

' Cont amin ate d : Equip, Etc.

Ci 8.28E+00 5.00E+01

^

i!

C.

Irradiated Components, Cu Meter 0.0 L

Control Rods, Etc.

Ci 0.0 0.0 D.

Other-(described-below)-

Mone j

d i

a i

a 9

l.,

l L

I l-r me w

+wese g--

9 e

M w--w--c-e-

.r

.-r-e g

w e-eew--ce--

y y

= -

  1. -m--

g.,

r.

E Pogo:12-

! I ONTICELLOLMUCLEAR-GENERATING PLANT' PeriodC Jul - Dec 1988 M

.NORTHERM-STATES 1 POWER COMPANY

-License No. DPR EFTLUEMT AND WASTE DISPOSAL.SEMIAMMUALcREPORT Table 3.= Solid?Wasta and Irradiated.Tuel Shipments (Continued) 2.1 Measured Major Nuclide Composition by Type of Wasten TYPE.

Muclide Percent i

A' Ba140 5.46E-01.

Cs137 1.42E+01 l

Cs134 5.08E+00 Sr90 1.18E Sr89 6.11E-01 r

Zn65 5.78E+00 Co60 3.37E+01 Mn54 2.70E+00 Cr51 6.44E-01 I 131 1.67E+00 Fe55 3.20E+01 Ba140 7.45E-02 B

Cs137 2.83E+00 Cs134 2.01E+00 j

SI90 1.63E-02 Sr89 2.39E-01 Zn65 2.97E+00 Co60 3.-52E+01-

'{

Fe59 1.49E-01 ji CoS8 3.37E-01 Mn54 5.71E+00 Cr51 1.47E+00-l Fe55 4.57E+01 l

L c

l l

l t

l I

i

er y

-e t

s c

5

.y PQgo'13 h [MONTICELLO' NUCLEAR-' GENERATING PLANT Period:

Jul - Dec 1988 NORTHERM! STATES" POWER COMPANY

' License No.-DPR-22 4 _

ETTLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

+

c

_ Table 3 (Solid Waste and Irradiated Tuel Shipments'(Continued) 3.

r, Solid Maste_ Dispositions Number offShiPnents Mode Destination o >

4-

. Truck Chem-Nuc Inc., Barnwell, SC 1-Truck US Ecology, Richland,_WA g,

1 Rail US Ecology,'Richland, WA B

Irraddated Tuel Shipments:

LNumber of Sh1Pnents Mode Destination None a

l' i

( ~.

l'

...., ~..

>y Ptgo 14 4,

,MONTICELLO-MUCLEAR GEXERATINO PLANT Period: 'Jul - Dec 1988

-XORTHERN STATES POWER COMPAXY License No. DPR-22 1

EPTLUENT AND WASTE DISPOSAL SEMIAMXilAL-REPORT Taule 3 Solid Waste and' Irradiated Tuel ShiPnents.(Continued)

C; Shipping Container and Solidification Method.:

Mo.-

Volume Activity Type of Container Solidification (M3)

(C1)

Waste Code Code L.

(88-22) 5.83E+00 1.59E+01 A

A (48-26) 5.66E+00 7.50E+00 B

L

-( 88-27 ) 5.83E+00 3.08E+01 A

A l

(88-30) 5.83E+00 1.68E+01 A

A (88-31) 3.19E+01 7.74E-01 B

L (80-34) 5.83E+00 2.20E+01 A

A r-CONTAINER CODES L - LSA u

A - Type A B - Type B 9 - Large Quantity

.SOLITICATION CODES:

C - Cement U - Urea Tornaldehyde h

9 4

)

+

Fr-j

, " ('

l PGgo 15 L

q

+

'MONTICELLO MUCLEAR GENERATING PLAXT Period 8 Jul - Dec 1988

(

NORTMERX STATES POWER COMPANY License Xo. DPR-22 ETFLUENT AND=WASTI DISPOSAL SEMIAXMUAL REPORT

- M; tass L

,l1. Release of individual noble gas isotopes from the Plant stack was determined using an isotopic analysis at the steam

)

30t air ejector.

Xe133, He135, Kr8SM, Kr88, Kr87, and Xo138 were. measured and used'to characterize the mode of gas IQ10ase dror the fuel.

Other significant noble gases were i

'd0tormined using known ratios, the measured total vidgas.

h31 dup system delay time, and the known fraction of the

'Odigas stream released _via the gland exhauster.

2. An isotopic analysis for noble gases is normally not Pcssible at the building va 's.

Individual isotopes are generally below their lower limit of detection (LLD).

Th0refore, for reactor _ building vant releases, the

{

noblo gas isotopic mixture is assumed to be the same as

.tho'nixture determined at the steam det air ejector.

3. Information specified in Regulatory Guide 1.21 which'is not applicable to the Monticello plant is

-indicated by

'NA'.

I

4. Nuclides not detected in plant effluents-(those b31cw:the LLD of the analysis) are not included in tho quantities reported released.

LLD values are recorded j

cnd must be less than the minimum LLD values stated in the Monticello Technical Specifications.

l

?

e b

?

H

..-,e,-,

en

,~.-,.-,-

w c-