y

-e C

Duke 1%uer Cornpany II<t B Tbs ~

.- e PO tht.Ul98 '

ilce hcsident Charlotte, N C 28242 hutlear1% duction (704)373 4531 DUKEPOWER November 15, 1989 g

l

~'

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk F

Washington, D.C.

20555

'l

Subject:

Catawba Nuclear Station, Unit 2 Docket No. 50-414 Twelfth Quarterly Update to Startup Report Gentlemen:

In accordance with Section 6.9.1.') of the Catawba Nuclear Station Technical Specifications, please find attached the twelfth qur.rterly update to the Unit 2 Startup Report. As indicated in my August 15, 1989 letter to NRC, one test is not complete. Additional quarterly updates to the Startup i

Report will be submitted as required by Technical Specifications.

Very truly yours, t

& /f. r - - - l i

.[

Hal B. Tucker o

hHH-6/lcs p

Attachment xc:

Mr. S. D. Ebneter Regional Administrator, RII U. S. Nuclear Regulatory Commission c-101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30301 3

Mr. W. T. Orders NRC Resident Inspector Catawba Nuclear Station s

x 8911220033 691115

[(1 DR ADOCK 0500 4

/

w u

1 I

i

.]

i STARTUP REPORT QUARTERLY UPDATE

)

CATAWBA UNIT 2 CYCLE 1 J

November 8, 1989 TESTING COMPLETED DURING OUARTER d

None.

i STATUS OF TESTING'NOT COMPLETE STEADY STATE PIPING SYSTEMS OPERATIONAL VIBRATION MEASUREMENT - TP/2/A/1200/21 l

This test was described !.n Sections-10.5 and 11.5 in the I

Startup Report.- It is complete except for retesting of piping associated with the Diesel Generator Fuel Oil and 1

Lube Oil systems.

Additional restraints were installed during the EOC-1 refueling outage.

However, further modifi-cations have been found to be necessary.

These modifications involve the replacemant of rigid piping with flexible piping.

It has been determined by Desigh Engineering that a Nuclear Station Modification will be necessary to perform this piping replacement.

Design work i

is nearing completion.

A qualified parts vendor has been determined.

Completion of.the test is dependent on these i

modifications.

It is expected that this modification will be completed in mid 1990.

i 1