Responds to NRC Re Violations Noted in IE Insp Repts 50-269/80-15 & 50-270/80-10 on 800415-17 & 21-23. Corrective Actions:Design of Calibr Blocks Reviewed & Will Be Modified to Meet ASME Requirements
ML19332A635
Person / Time
Site: Oconee  
Issue date: 06/23/1980
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19332A630 List:
References
NUDOCS 8009160541
Download: ML19332A635 (2)


Text

p

.. ~.. -. _.... -....

~

x J.

O DUKE POWER COMPANI G ON ::

,.J S N R O R E ITL A N'T A. C' E # O Powra Bun.onwo 422 Socra Cuuncu Srazer, CnAntortz, N. C. asa4a wiwaw o. a^aata.sa.

June 23, 1980

'd 0.un I n8: 58 VeCE PatsacENT TttremoNt:Anta 704

$ttano Pm0 duction 373-4083 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region Il 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 l

l Re: RII:NE 50-269/80-15 50-270/80-10 l

Dear Sir:

i With regard to Mr. C. E. Murphy's letter of May 22, 1980 which transmitted the subject inspection report, Duke Power Company does not consider the informa-tion contained therein to be proprietary.

Please find attached responses to the cited items of noncompliance.

I V y truly yours, l

/

a.

i William O. Parker, Jr.

FTP:ses Attachment g

l i.

B009160Nl-OiTICIAL C6M'

DUKE POWER COMPANY OCONEE NUCLEAR STATION Response to IE Inspection Report 50-269-15, -270/80-10 ITEM As required by (g)(4) of 10CFR 50.55(a) and implemented by the Technical Specification, Paragraph 4.2, as updated, requires the surveillance program of Class 1, Class 2... components comply with ASME Section'XI (74S75). Para-graphs 1-3131 and I-3210 require that basic calibration block configuration reflector size and location comply with Figure I-3131.

Contrary to the above requirement, on April 15, 1980, the size and location of holes and notches (reflectors) on LSI basic calibration blocks Nos. 40303 and 40304 did not comply with Figure 1-3131 of the above ASME Section XI code.

This is an infraction.

RESPONSE

In response to item 50-270/80-10-01, improperly designed ISI calibration blocks, all Oconee ISI calibration blocks and drawings were reviewed.

Several blocks were found with reflectors which do not fully meet the requirements of ASME Section XI, 1974 edition through S75 addenda. The design of these blocks are being reviewed, and they will be modified to meet the code requirements, if possible, by adding additional reflectors.

In those cases where adding reflectors would interfere with the calibration, we intend to request relief to use the reflectors now in the blocks.

.